scholarly journals Three-year clinical and radiological results of a cruciate-retaining type of the knee prosthesis with anatomical geometry developed in Japan

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Arata Nakajima ◽  
Manabu Yamada ◽  
Masato Sonobe ◽  
Yorikazu Akatsu ◽  
Masahiko Saito ◽  
...  

Abstract Background The FINE total knee was developed in Japan and clinical use began in 2001. It has unique design features, including an oblique 3o femorotibial joint line that reproduces anatomical geometry. Although 20 years have passed since the FINE knee was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken. Methods A total of 175 consecutive primary cruciate-retaining (CR)-FINE total knee arthroplasties (TKAs) at our hospital between February 2015 and March 2017 were included in this study. Three years postoperatively, range of motion (ROM), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Forgotten Joint Score (FJS) were recorded and compared with preoperative scores. Radiographic analyses including mechanical alignment, component alignment, and incidence of radiolucent lines also were undertaken based on the radiographs 3 years postoperatively. Results One-hundred twenty-two knees (70%) were available for 3-year follow-up data using KOOS, except for the sports subscale. Postoperative KOOS-symptom, −pain and -ADL were > 85 points, but KOOS-sports, −QOL and FJS were less satisfactory. ROM, KSS and all the subscales of KOOS were significantly improved compared with preoperative scores. Postoperative mean FJS was 66 and was significantly correlated with all the subscales of KOOS, but not with postoperative ROM. Radiolucent lines ≧1 mm wide were detected in five knees (4.1%). There were no major complications needing revision surgeries. Conclusions Patient-reported outcomes (PROs) for symptoms, pain and ADL after the CR-FINE TKA were generally improved, but those for sports, QOL and FJS were improved less. The incidence of radiolucent lines was rare but detected around the femoral components. With the mid- to long-term follow-up, improvements of surgical technique will be necessary to achieve better PROs from patients receiving the FINE knee.

2020 ◽  
Author(s):  
Arata Nakajima ◽  
Manabu Yamada ◽  
Masato Sonobe ◽  
Yorikazu Akatsu ◽  
Masahiko Saito ◽  
...  

Abstract Background: The FINE total knee was developed in Japan and clinical use began in 2001. It has unique design features, including an oblique 3o femorotibial joint line that reproduces anatomical geometry. Although 20 years have passed since the FINE knee was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken.Methods: A total of 175 consecutive primary cruciate-retaining (CR)-FINE total knee arthroplasties (TKAs) at our hospital between February 2015 and March 2017 were included in this study. Three years postoperatively, range of motion (ROM), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Forgotten Joint Score (FJS) were recorded and compared with preoperative scores. Radiographic analyses including mechanical alignment, component alignment, and incidence of radiolucent lines also were undertaken based on the radiographs three years postoperatively.Results: One-hundred twenty-two knees (70%) were available for 3-year follow-up data using KOOS, except for the sports subscale. Postoperative KOOS-symptom, -pain and -ADL were > 85 points, but KOOS-sports, -QOL and FJS were less satisfactory. ROM, KSS and all the subscales of KOOS were significantly improved compared with preoperative scores. Postoperative mean FJS was 66 and was significantly correlated with all the subscales of KOOS, but not with postoperative ROM. Radiolucent lines ≧1 mm wide were detected in five knees (4.1%). There were no major complications needing revision surgeries.Conclusions: Patient-reported outcomes (PROs) for symptoms, pain and ADL after the CR-FINE TKA were generally improved, but those for sports, QOL and FJS were improved less. The incidence of radiolucent lines was rare but detected around the femoral components. Improvements of surgical technique or innovation of the implant design with mid- to long-term follow-up will be necessary to achieve better PROs from patients receiving the FINE knee.


2021 ◽  
Author(s):  
Shuai Xiang ◽  
Yingzhen Wang ◽  
Chengyu Lv ◽  
Changyao Wang ◽  
Haining Zhang

Abstract Background The aim of this study was to compare the mid-term clinical and radiographic outcomes between medial-pivotal (MP) insert and double-high (DH) insert used under cruciate-retaining condition in ADVANCE® total knee arthroplasty (TKA). Methods The follow-up was conducted for 158 consecutive patients underwent unilateral ADVANCE® TKA from January 2011 to April 2014. 84 MP inserts and 74 DH inserts were used under cruciate-retaining condition. A 1:1 propensity score matching (PSM) analysis was performed between MP insert and DH insert to compare the clinical and radiographic outcomes. Results After a 1:1 PSM, 120 patients (60 pairs) were matched between MP insert and DH insert. The baseline demographic parameters and clinical scores were comparable between the two groups. The postoperative clinical outcomes at an averaged 8-year follow-up of both groups were significantly improved. The range of motion (ROM) of DH group was better than that of MP group and equivalent Knee Society Function Score (KSFS) between the two groups was found. However, the Knee Society Score (KSS), Western Ontario and McMaster Universities Arthritis Index (WOMAC) score and Forgotten Joint Score (FJS) of MP group were found to be significantly superior than those of DH group. Comparable complication rate and revision rate were observed between the two groups. The radiographic results were also equally good between MP and DH group. Conclusions Although the mid-term clinical and radiographic outcomes of DH insert are fairly good, the clinical scores of DH group were worse than those of MP group.


2020 ◽  
Vol 35 (1) ◽  
pp. 272-277 ◽  
Author(s):  
Jordan S. Broberg ◽  
Silvio Ndoja ◽  
Steven J. MacDonald ◽  
Brent A. Lanting ◽  
Matthew G. Teeter

Author(s):  
Mattia Alessio-Mazzola ◽  
Antonio Clemente ◽  
Antonio Russo ◽  
Peter Mertens ◽  
Giorgio Burastero ◽  
...  

Abstract Background Total knee arthroplasty is a reliable procedure able to reduce pain and disability in patients suffering from osteoarthritis. However, a considerable percentage of patients still experiences unsatisfactory results. Medial pivot total knee arthroplasty has been introduced in the clinical practice to overcome problems related with classic design implants and better mimic native knee kinematics. The aim of this study was to analyze survivorship and clinical and radiographic outcomes of medial pivot implants. Methods A systematic research was conducted in eight different databases. Thirty-four studies met the inclusion criteria and were included in the analysis. Data on objective and patients-reported outcomes, radiographic alignment, and survivorship were collected and analyzed. Revision rate was expressed as revision per 100 components years. Result A total of 3377 procedures were included. Mean follow-up was 85.7 months (range, 12–182). The revision per 100 components years was 0.19, which corresponds to a revision rate of 1.9% after 10 years. Mean post-operative range of motion was 117.3 ± 0.4°. Mean clinical and functional Knee Society Score were, respectively, 85.9 ± 1.1 and 84.7 ± 3.5 at final follow-up. Post-operative femorotibial alignment was 177.1 ± 0.5°. Alfa and beta angles were 95.7 ± 0.1° and 89.2 ± 0.1°, respectively. Gamma and delta angles were 2.3 ± 0.6° and 86.7 ± 0.4°. Conclusion Medial pivoting implants provided excellent survivorship and low revision rate, as well as good-to-excellent results in term of objective and patient-reported clinical outcomes, and reliable correction of radiographic parameters. More high-quality studies with long-term follow-up are needed to clarify the role of medial pivoting implants.


2013 ◽  
Vol 7 (1) ◽  
pp. 152-157 ◽  
Author(s):  
Jean-Baptiste Chavoix

Background: Mobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a highly congruent mobile platform design, the e.motion® UC total knee prosthesis. Material and Methods: Functional and clinical outcomes were assessed after an average of 5.6 years (5.1 – 6.0 years) after total knee arthroplasty in 28 patients (24 women), aged 77.8±7.5 years. The Knee injury and Osteoarthritis Outcome Score (KOOS) was assessed. Secondary outcomes included the Knee Society Score (KSS), radiological evaluation of radiolucent lines and recording of adverse events. Results: The average KOOS subscore for the activities of daily life was 77.8 points after 5.6 years. Both the clinical and functional KSS improved at 2.4 and 5.6 years. Two patients showed radiolucent lines at 5.6 years. Adverse events over 5.6 years included 3 subluxations, 1 tilting and 1 misalignment of the patella. None of the prostheses were revised. Conclusion: This pilot study shows promising outcomes for the e.motion® UC prosthesis. In the small sample, the implant performed comparably to the LCS prosthesis (the gold standard). There were no loosenings or revisions observed at 5.6 years.


2018 ◽  
Vol 100-B (10) ◽  
pp. 1336-1344 ◽  
Author(s):  
A. J. Powell ◽  
E. Crua ◽  
B. C. Chong ◽  
R. Gordon ◽  
A. McAuslan ◽  
...  

Aims This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. Patients and Methods A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups. Results At the ten-year follow-up, the RP group (n = 39) had a statistically significant superior score in the OKS (p = 0.001), WOMAC (p = 0.023), SF-12 PCS (p = 0.019), KOOS Activities of Daily Living (ADL) (p = 0.010), and KOOS Sport and Recreation (Sport/Rec) (p = 0.006) compared with the FB group (n = 46). The OKS, SF-12 PCS, and KOOS Sport/Rec at ten years had mean scores above the minimal clinically important difference (MCID) threshold. There was no significant difference in prevalence of radiolucency between groups at five-years’ follow-up (p = 0.449), nor at ten-years’ follow-up (p = 0.08). Implant survival rate at 14 years postoperative was 95.2 (95% CI 90.7 to 99.8) and 94.7 (95% CI 86.8 to 100.0) for the RP and FB TKAs, respectively. Conclusion At ten-year follow-up, the mobile-bearing knee joint arthroplasty had statistically and clinically relevant superior OKS, SF-12 PCS, and KOOS (Sport/Rec) than the fixed-bearing platform. No difference was seen in prevalence of radiolucent lines. There was a greater than 94% implant survival rate for both cohorts at 14 years. Cite this article: Bone Joint J 2018;100-B:1336–44.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.