scholarly journals Structural alteration of lung parenchyma in patients with NF1: a phenotyping study using multidetector computed tomography (MDCT)

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Maxim Avanesov ◽  
Lennart Well ◽  
Azien Laqmani ◽  
Thorsten Derlin ◽  
Vincent M. Riccardi ◽  
...  

Abstract Background Diffuse interstitial lung disease have been described in Neurofibromatosis type 1 (NF1), but its diversity and prevalence remain unknown. The aim of this study was to assess the prevalence and characteristics of (NF1)-associated lung manifestations in a large single-center study using multidetector computed tomography (MDCT) and to evaluate the smoking history, patients’ age, genetics, and the presence of malignant peripheral nerve sheath tumors (MPNST) as potential influencing factors for lung pathologies. Methods In this retrospective study, 71 patients with NF1 were evaluated for the presence of distinctive lung manifestations like reticulations, consolidations, type of emphysema, pulmonary nodules and cysts. All patients underwent F-18-FDG PET/CT scans, which were reviewed by two experienced radiologists in consensus. Patients’ subgroups were formed based on their smoking history (current smokers/previous smokers/never smokers), age (< 12 years, 12–18 years, > 18 years), and presence of MPNST (MPNST/no MPNST). In 57 patients (80%), genetic analysis of sequences coding for the neurofibromin on chromosome 17 was performed, which was correlated with different lung pathologies. Results Among all NF1 patients (33 ± 14 years, 56% females), 17 patients (24%) were current smokers and 62 patients (87%) were > 18 years old. Pulmonary cysts, nodules, and paraseptal emphysema were the most common pulmonary findings (35%, 32%, 30%). The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking. Cysts were observed only in adults, whereas no significant correlation between age and all other pulmonary findings was found (p > 0.05). Presence of MPNST was accompanied by higher rates of intrapulmonary nodules and pulmonary metastasis. Neither the presence nor absence of any of the specific gene mutations was associated with any particular lung pathology (p > 0.05). Conclusions All pulmonary findings in NF1 patients occurred independently from specific mutation subtypes, suggesting that many NF1 mutations can cause various pulmonary pathologies. The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking, indicating the value of smoking secession or the advice not to start smoking in NF1 patients as preventive strategy for clinicians. For screening of pulmonary manifestations in NF1 patients, an MDCT besides medical history and physical examination is mandatory in clinical routine.

2008 ◽  
Vol 58 (3) ◽  
pp. 277
Author(s):  
Ji Sang Park ◽  
Seong Jin Park ◽  
Hae Kyung Lee ◽  
Boem Ha Yi ◽  
Hyun Sook Hong ◽  
...  

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2010 ◽  
Vol 13 (3) ◽  
pp. E198-E199
Author(s):  
Yi-Chang Lin ◽  
Yi-Ting Tsai ◽  
Chih-Yuan Lin ◽  
Chung-Yi Lee ◽  
Gou-Jieng Hong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document