scholarly journals Gas embolism under standard versus low pneumoperitoneum pressure during laparoscopic liver resection (GASES): study protocol for a randomized controlled trial

Trials ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Danfeng Jin ◽  
Mingyue Liu ◽  
Jian Huang ◽  
Yongfeng Xu ◽  
Luping Liu ◽  
...  

Abstract Background Gas embolism induced by CO2 pneumoperitoneum is commonly identified as a risk factor for morbidity, especially cardiopulmonary morbidity, after laparoscopic liver resection (LLR) in adults. Increasing pneumoperitoneum pressure (PP) contributes to gas accumulation following laparoscopy. However, few studies have examined the effects of PP in the context of LLR. In LLR, the PP-central venous pressure (CVP) gradient is increased due to hepatic vein rupture, hepatic sinusoid exposure, and low CVP management, which together increase the risk of CO2 embolization. The aim of this study is to primarily determine the role of low PP (10 mmHg) on the incidence of severe gas embolism. Methods Adult participants (n = 140) undergoing elective LLR will be allocated to either a standard (15 mmHg) or low (10 mmHg) PP group. Anesthesia management, postoperative care, and other processes will be performed similarly in both groups. The occurrence of severe gas embolism, which is defined as gas embolism ≥ grade 3 according to the Schmandra microbubble method, will be detected by transesophageal echocardiography (TEE) and recorded as the primary outcome. The subjects will be followed up until discharge and followed up by telephone 1 and 3 months after surgery. Postoperative outcomes, such as the Post-Operative Quality of Recovery Scale, pain severity, and adverse events, will be assessed. Serum cardiac markers and inflammatory factors will also be assessed during the study period. The correlation between intraoperative inferior vena cava-collapsibility index (IVC-CI) under TEE and central venous pressure (CVP) will also be explored. Discussion This study is the first prospective randomized clinical trial to determine the effect of low versus standard PP on gas embolism using TEE during elective LLR. These findings will provide scientific and clinical evidence of the role of PP. Trial status Protocol version: version 1 of 21-08-2020 Trial registration ChiCTR2000036396 (http://www.chictr.org.cn). Registered on 22 August 2020.

CHEST Journal ◽  
2009 ◽  
Vol 136 (4) ◽  
pp. 117S
Author(s):  
Glynn W. Gilcrease ◽  
James N. Phan ◽  
Brian K. Showalter ◽  
Nathaniel Torres ◽  
Bruce J. Kimura

2021 ◽  
Vol 30 (4) ◽  
pp. 230-236
Author(s):  
Barry Hill ◽  
Catherine Smith

Patients who present with acute cardiovascular compromise require haemodynamic monitoring in a critical care unit. Central venous pressure (CVP) is the most frequently used measure to guide fluid resuscitation in critically ill patients. It is most often done via a central venous catheter (CVC) positioned in the right atrium or superior or inferior vena cava as close to the right atrium as possible. The CVC is inserted via the internal jugular vein, subclavian vein or via the femoral vein, depending on the patient and their condition. Complications of CVC placement can be serious, so its risks and benefits need to be considered. Alternative methods to CVC use include transpulmonary thermodilution and transoesophageal Doppler ultrasound. Despite its widespread use, CVP has been challenged in many studies, which have reported it to be a poor predictor of haemodynamic responsiveness. However, it is argued that CVP monitoring provides important physiologic information for the evaluation of haemodynamic instability. Nurses have central roles during catheter insertion and in CVP monitoring, as well as in managing these patients and assessing risks.


2016 ◽  
Vol 200 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Eva See Wah Cheng ◽  
Julie Hallet ◽  
Sherif S. Hanna ◽  
Calvin H.L. Law ◽  
Natalie G. Coburn ◽  
...  

2019 ◽  
Vol 6 (5) ◽  
pp. 1947
Author(s):  
Mohd Kashif Ali ◽  
Eeman Naim

Background: Ultrasound guided fluid assessment in management of septic shock has come up as an adjunct to the current gold standard Central Venous Pressure monitoring. This study was designed to observe the respiro-phasic variation of IVC diameter (RV-IVCD) in invasively mechanically ventilated and spontaneously breathing paediatric patients of fluid refractory septic shock.Methods: This was a prospective observational study done at Paediatric intensive Care Unit (PICU) in Paediatric ward of Jawaharlal Nehru Medical College and Hospital (JNMCH) from February 2016 to June 2017. 107 consecutive patients between 1 year to 16 years age who were in shock despite 40ml/kg of fluid administration were included. Inferior Vena Cava (IVC) diameters were measured at end-expiration and end inspiration and the IVC collapsibility index was calculated. Simultaneously Central Venous Pressure (CVP) was recorded. Both values were obtained in ventilated and non-ventilated patients. Data was analysed to determine to look for the profile of RV-IVCD and CVP in ventilated and non-ventilated cases.Results: Out of 107 patients, 91 were on invasive mechanical ventilation and 16 patients were spontaneously breathing. There was a strong negative correlation between central venous pressure (CVP) and inferior vena cava collapsibility (RV-IVCD) in both spontaneously breathing (-0.810) and mechanically ventilated patients (-0.700). Negative correlation was significant in both study groups in CVP <8 mmHg and only in spontaneously breathing patients in CVP 8-12 mmHg range. IVC collapsibility showed a decreasing trend with rising CVP in both spontaneously breathing and mechanically ventilated patients.Conclusion: Ultrasonography guided IVCCI appears to be a valuable index in assessing fluid status in both spontaneously breathing and mechanically ventilated septic shock patients. However, more data is required from the paediatric population so as to define it as standard of practice.


2020 ◽  
Vol 5 (1) ◽  

Fluid therapy is an essential component part management of critically ill patients. Proper estimation of the amount of needed fluids is of great importance due to the well-established adverse effects of marked negative and positive fluids balance. Central venous pressure has been widely used by ICU physicians for volume status assessment. Several methods have been postulated for volume status assessment, among which is the inferior vena cava collapsibility index. As the inferior vena cava is a thin-walled capacitance vessel that adjusts to the body’s volume status by changing its diameter depending on the total body fluid volume. Giving the fact that bed-side ultrasonographic measurement of inferior vena cava diameters is an available, non-invasive, reproducible and quiet easy-to-learn technique, it can provide a safe and quiet reliable replacement of central venous pressure measurement for assessment of volume status assessment. The aim of this study was to find statistical correlation between central venous pressure and caval index, as a step towards validating the above mentioned replacement. 86 critically ill patients from ICU population were enrolled. Simultaneous measurements of central venous pressure and inferior vena cava collapsibility index were observed and recorded on four sessions. Patients were also grouped based on their mode of ventilation and central venous pressure values in order to compare the strength of correlation between various populations. The results showed that Inferior vena cava collapsibility index has significant inverse correlation with CVP value (r= -85, p value ˂0.001 at 95% CI) and it better correlated with mean arterial blood pressure and lactate clearance as compared to central venous pressure. However it correlated better with CVP in spontaneously breathing patients (r= -0.86, p value ˂0.001) than in mechanically ventilated patients (r= -0.84, p value ˂0.001). Inferior vena cava collapsibility index has shown to correlate better with CVP value in lower values (˂ 10 cmH2O) (r= -0.8, p value ˂0.001) than in higher values (≥ 10 cmH2O) (r= -0.6, p value ˂0.001). In addition, an inferior vena caval collapsibility index cut-off value of 29% was shown to discriminate between CVP values ˂10 cmH2O and values ≥10 cmH2O with high Sensitivity (88.6%) and specificity (80.4%). In conclusion, inferior vena cava collapsibility index has a strong inverse relationship with central venous pressure which is more pronounced at low central venous pressure values. Point-of-care ultrasonographically-measured inferior vena cava collapsibility index is very likely to be a good alternative to central venous pressure measurement with a high degree of precision and reproducibility. However, Wide scale studies are needed to validate its use in different patient populations.


Author(s):  
Vikram Aggarwal ◽  
Yoonju Cho ◽  
Aniruddha Chatterjee ◽  
Dickson Cheung

Central venous pressure (CVP) is a measure of the mean pressure within the thoracic vena cava, which is the largest vein in the body and responsible for returning blood from the systemic circulation to the heart. CVP is a major determinant of the filling pressure and cardiac preload, and like any fluid pump, the heart depends on an adequate preload to function effectively. Low venous return translates into a lower preload and a drop in overall cardiac output, a relationship described by the Frank-Starling Mechanism. CVP is an important physiological parameter, the correct measure of which is a clinically relevant diagnostic tool for heart failure patients. In addition to other vitals such as heart rate and mean arterial pressure, accurate measures of central venous pressure through simple diagnostic instrumentation would provide physicians with a clear picture of cardiac functionality, and allow for more targeted treatment. Recent literature has also shown that measuring CVP can be an important hemodynamic indicator for the early identification and treatment of more widespread conditions, such as sepsis (Rivers, Nguyen, Havstad, & Ressler, 2001). With over five million patients (American Heart Association, http://www.americanheart.org/presenter. jhtml) in the U.S. presenting with heart failure-like symptoms annually, a current challenge for physicians is to obtain a quick and accurate measure of a patient’s central venous pressure in a manner that poses minimum discomfort.


Sign in / Sign up

Export Citation Format

Share Document