scholarly journals Weight of evidence approach using a TK gene mutation assay with human TK6 cells for follow-up of positive results in Ames tests: a collaborative study by MMS/JEMS

2021 ◽  
Vol 43 (1) ◽  
Author(s):  
Manabu Yasui ◽  
Takayuki Fukuda ◽  
Akiko Ukai ◽  
Jiro Maniwa ◽  
Tadashi Imamura ◽  
...  

Abstract Background Conflicting results between bacterial mutagenicity tests (the Ames test) and mammalian carcinogenicity tests might be due to species differences in metabolism, genome structure, and DNA repair systems. Mutagenicity assays using human cells are thought to be an advantage as follow-up studies for positive results in Ames tests. In this collaborative study, a thymidine kinase gene mutation study (TK6 assay) using human lymphoblastoid TK6 cells, established in OECD TG490, was used to examine 10 chemicals that have conflicting results in mutagenicity studies (a positive Ames test and a negative result in rodent carcinogenicity studies). Results Two of 10 test substances were negative in the overall judgment (20% effective as a follow-up test). Three of these eight positive substances were negative after the short-term treatment and positive after the 24 h treatment, despite identical treatment conditions without S9. A toxicoproteomic analysis of TK6 cells treated with 4-nitroanthranilic acid was thus used to aid the interpretation of the test results. This analysis using differentially expressed proteins after the 24 h treatment indicated that in vitro specific oxidative stress is involved in false positive response in the TK6 assay. Conclusions The usefulness of the TK6 assay, by current methods that have not been combined with new technologies such as proteomics, was found to be limited as a follow-up test, although it still may help to reduce some false positive results (20%) in Ames tests. Thus, the combination analysis with toxicoproteomics may be useful for interpreting false positive results raised by 24 h specific reactions in the assay, resulting in the more reduction (> 20%) of false positives in Ames test.

2011 ◽  
Vol 26 (2) ◽  
pp. 94-101 ◽  
Author(s):  
Delphine Vezzosi ◽  
Thomas Walter ◽  
Agnès Laplanche ◽  
Jean Luc Raoul ◽  
Clarisse Dromain ◽  
...  

Background Multiple causes of false-positive chromogranin A (CgA) measurement have been reported that may affect its impact as a surrogate marker of RECIST progression in well-differentiated gastroenteropancreatic neuroendocrine tumors (WDGEPNET). Aims 1) To evaluate the frequency of false-positive CgA results. 2) To prospectively compare CgA variations with RECIST morphological changes in patients without known causes of false-positive CgA measurements. Methods First, the conditions responsible for potentially false-positive CgA measurements were screened in 184 consecutive patients with metastatic WDGEPNET. Secondly, a variation in CgA at a 6-month interval was compared to RECIST results at 6 months in 46 patients. Results Among 184 patients, elevated CgA was found in 130 cases (71%) including 99 patients with at least one cause of a false-positive result. Impaired kidney function as well as medication with proton pump inhibitors were found to be the 2 major causes of false-positive results. The sensitivity and specificity of CgA measurements compared with morphological tumor changes according to the RECIST criteria were 71% and 50%, respectively, at 6 months. Conclusion Routine screening for the causes of false-positive CgA measurements is mandatory in WDGEPNET patients. Our study does not validate the use of CgA as a surrogate marker of tumor progression.


2014 ◽  
Vol 61 (4) ◽  
pp. 293-299 ◽  
Author(s):  
T. Rosseel ◽  
B. Pardon ◽  
K. De Clercq ◽  
O. Ozhelvaci ◽  
S. Van Borm

1994 ◽  
Vol 10 (1) ◽  
pp. 33-40 ◽  
Author(s):  
Jane Wardle ◽  
Amanda Pernet ◽  
William Collins ◽  
Thomas Bourne

Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 1524-1524
Author(s):  
Silmara Lima Montalvão ◽  
Sandra Martins Silva Soares ◽  
Marina P Colella ◽  
Joyce M Annichino-Bizzacchi ◽  
Samuel de Souza Medina ◽  
...  

Abstract The diagnosis of von Willebrand Disease (VWD) remains a challenge of daily hematology practice. Ristocetin cofactor activity (VWF:RCo) is an important parameter for the diagnosis of VWD and is also essential for its management. However, reproducibility of the available tests for VWF:RCo is still a major issue, as evidenced by coefficient of variations (CV) as high as 30%, 45% and 27% in the ECAT, NEQAS and PALQ external quality assessment program. Classical methods to measure VWF:RCo include light-transmission platelet agregometry (LPA) and visual agglutination with formaldehyde fixed human platelet (VA), and more recently, VWF activity based on automated latex immunoassay (LIA). The glycoprotein (GP) Ibα is the main receptor for von Willebrand factor (VWF) in the platelet membrane. Currently, two automated methods with immobilized GPIbα have been developed to improve the sensitivity and specificity of VWF:RCo. One of them is performed with ristocetin while the other one uses a mutant GPIbα with gain of function and does not require ristocetin. This study aims to compare the two assays using immobilized GPIbα with other four assays for VWF functional determination, in patients with confirmed and under investigation for VWD. We evaluated six different VWF functional assays: VWF:RCo LPA (Chrono-Log); VA (Siemens); VA in house (with ristocetin from Chrono-Log); automated-LIA (Hemosil); in comparison to two assays using immobilized GPIbα with or without ristocetin, the GPIbα-ristocetin (Hemosil), and GPIbα-mutant (Siemens Innovance). Reference ranges for each method were established in 20 healthy adults. Plasma samples collected at the same time from 40 individuals were used in this comparative study, with 25 type 1 VWD, 2 type 3 VWD, and 13 under investigation. Diagnosis of VWD was based on bleeding history (evaluated by MCMDM-1VWD Bleeding Score), historical levels of VWF antigen (VWF:Ag) by ELISA, and VWF:RCo (assayed by LTA or VA) obtained from medical records. Statistical analysis were performed based on linear regression (Spearman correlation), agreement test (Altman Bland), and chi-square test using Prism 6.0. When all 40 patients were evaluated for both methods, GPIbα-ristocetin and GPIbα-mutant, we observed a good coefficient of correlation (r = 0.8954; p<0.0001). However, when 7 type 1 VWD patients, and 1 under investigation case were evaluated for the six methods, the two using immobilized GPIbα showed lower median (16.78 ± 4.62 with GPIbα-ristocetin, and 16.28 ± 4.29 with GPIbα-mutant), when compared with the other four assays (LTA: 22.38 ± 5.5; VA in house: 21.45 ± 4.87; VA Siemens: 22.65 ± 4.9; and LIA: 24.19 ± 9.0). In this group, when the bleeding score (BS) were ≥ 5, the VWF functional results were lower than 25 IU/dL, using all six methods (figure). Among 13 individuals under VWD investigation, GPIbα-ristocetin and GPIbα-mutant showed good agreement with the LTA/VA results and clinical history, and we could concluded that 4 have VWD, and for 4 individuals VWD was excluded. However, 2 individuals with no history of bleeding presented abnormal results for GPIbα-ristocetin and GPIbα-mutant, showing probably false positive results. One patient with no bleeding history, and abnormal LTA/VA results had normal GPIbα-ristocetin and GPIbα-mutant results, demonstrating poor reproducibility and precisian of the classical methods. On the other hand, two patient with BS 6, the diagnosis of VWD was demonstrating only by immobilized GPIbα methods. The VWF:RCo is a cumbersome assay and can be affected by polymorphisms present in the ristocetin binding site of VWF. Recently, new technologies have been developed to improve the VWF functional evaluation. It is consensus that methodologies using platelets are more accurate than other methods. Therefore, immobilized GPIbα has the objective to improve the sensitivity and specificity. Besides good results of concordance between immobilized GPIbα in the group of VWD patients and for 62% individual under investigation, we also observed false positive results related with these methods. The presence or absence of ristocetin on the immobilized GPIbα setting appear not engender different results in this study. In general, this new technologies present better precision compared to VA and LTA. Figure 1 Figure 1. Disclosures No relevant conflicts of interest to declare.


PEDIATRICS ◽  
1976 ◽  
Vol 58 (4) ◽  
pp. 508-512
Author(s):  
Jay Y. Gillenwater ◽  
Charles H. Gleason ◽  
Jacob A. Lohr ◽  
Donald Marion

Bacteriuria screening on 289 children was performed by their parents by means of a self-administered dip-strip culture which was inoculated, incubated, and interpreted in the home. Simultaneous pour-plate quantitative cultures and laboratory-tested dip-strip cultures were done on the same urine specimen which had been tested at home. The dip-strip culture was reliable (89%) in detecting significant bacteriuria with home administration and interpretation. Only 1.6% false-positive results occurred in the home testing. The dip-strip home cultures are an effective way for screening or follow-up of patients with bacteriuria.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 5014-5014
Author(s):  
Silvia Cantoni ◽  
Erika Ravelli ◽  
Maria Cristina Moioli ◽  
Chiara Rusconi ◽  
Vittorio Ruggero Zilioli ◽  
...  

Abstract Abstract 5014 Introduction Risk of developing non Hodgkin lymphomas (NHL) is known to be increased among patients (pts) infected by HIV-1 and sporadic non-HIV related cases of Hodgking lymphomas (HL) are also described. HIV-positive pts also feature a virus-related systemic lymphoadenopathy which makes nodal involvement by lymphoma difficult to evaluate using conventional imaging. The role of positron-emission tomography using 18F-fluorodeoxyglucose (FDG-PET) in the staging and evaluation of response to treatment of pts with NHL and HL is well established in immunocompetent pts, while only limited information is available on lymphomas arising in the setting of HIV infection. We report on a retrospective analysis of FDG-PET results in a group of HIV pts with lymphoma, both NHL and HL, followed-up at our hospital. Patients and methods Twelve HIV-positive male pts with a diagnosis of lymphoma (7 high grade and 1 follicular NHL, 4 HL) underwent a total of 22 PET scans. PET results were compared with those obtained by computed tomography (CT). Nine PET were performed at staging, 7 at restaging following chemotherapy, and 6 at follow-up. At diagnosis of lymphoma: median CD4 count was 200 cells/mcL (range 98-451); HIV genome was undetectable in 5/9 pts, in the remaining 4 pts for whom the data was available viral loads ranged from 103 to 1,452,720 copies/mL; 10/12 pts were already receiving HAART, while the remaining 2 pts started treatment upon diagnosis of lymphoma. Results In the majority of cases (17/22 = 77%) results of PET, CT scan and clinical status were concordant, being diagnostic of either lymphoma presence (11/17) or absence (6/17). No false positive results were recorded at follow-up. In 5/22 cases (23%) PET and CT scan were discordant. In 4 cases PET yielded a false negative result; in 2 cases at diagnosis (2 pts with HL) and in 2 cases at follow-up (both in the pt with follicular lymphoma). In the remaining case, a PET-negative CT-positive adenopathy was demonstrated which proved to be reactive in nature at biopsy. Discussion Our results suggest that FDG-PET is useful in the evaluation of lymphoma in the setting of HIV infection, similarly to what has been observed among immunocompetent pts. Although the number of patients is limited, in our experience PET proved to be able to discriminate between reactive and lymphomatous involvement of lymphoid tissue as demonstrated by absence of false positive results in pts evaluated at follow-up. These results need to be confirmed by larger clinical trials. Disclosures No relevant conflicts of interest to declare.


1990 ◽  
Vol 5 (4) ◽  
pp. 159-165 ◽  
Author(s):  
A. Jiménez-Vicioso ◽  
M. Torres ◽  
A. Jiménez-Heffernan ◽  
M.D. Grana ◽  
J.M. Latre ◽  
...  

To evaluate the clinical usefulness of immunoscintigraphy with OC 125 in ovarian carcinoma, we studied 25 patients suspected of having ovarian carcinoma or in follow-up after surgery. Fourteen patients were studied with 131I-OC 125 F(ab')2 and 11 with 111In-OC 125 F(ab')2. No differences were observed with the use of either radionuclide. Global diagnostic indexes obtained were S = 100%, Sp = 44,5% and A = 81%. The low specificity obtained was remarkable: 5 false positive results in two uterine myomas, one abscess, one follicular cyst and one granulation tissue scar. On the other hand, all lesions of ovarian carcinoma were detected. Analysis of the evolution of tumor/background (T/B) uptake ratios from the first to the second day of exploration revealed a tendency for the ratio to diminish significantly (> 15%) in false positive cases with the exception of the abscess while this did not happen in true positive cases, with the exception of a regional recurrence. Analysis of T/B ratio variations could contribute towards elevating the test's specificity.


Author(s):  
Nassirah Khandoudi ◽  
Pierre Porte ◽  
Sami Chtourou ◽  
Fabrice Nesslany ◽  
Daniel Marzin ◽  
...  

2016 ◽  
Vol 60 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Shafqat Mehmood ◽  
Asif Loya ◽  
Muhammed Aasim Yusuf

Purpose: To evaluate the diagnostic yield of biliary brush cytology and the factors affecting positive results in patients with biliary strictures. Patients and Methods: The medical records of all patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) with biliary brush cytology at our institution from November 2004 to December 2013 were reviewed in this retrospective study. The yield of positive brush cytology and the factors affecting positive yield, such as stricture location, age, gender and preprocedure CA 19.9 level were assessed. The final histopathology, diagnosis obtained by other methods, such as endoscopic ultrasound-guided fine-needle aspiration cytology, CT scan, Tru-Cut biopsy and/or clinical/radiological follow-up were used to identify true- and false-positive/negative results. The brush cytology results were divided into 4 main categories: malignant, benign, atypical cells and inadequate. Results: A total of 1,168 patients underwent ERCP during this 9-year period. Out of these, 142 patients had ERCP and biliary brushings for diagnosis. The mean age of the patients at presentation was 58.7 years (range 23-84 years; 64.8% males). The indication for referral was obstructive jaundice in all patients. Of the 142 patients, 77 (54.2%) had a distal common bile duct (CBD) stricture and 65 (45.8%) had a proximal /complex hilar stricture. The strictures were classified as proximal or distal, based on their relationship with the cystic duct; those below the cystic duct insertion were classified as distal and those above it were considered proximal. The diagnostic yield of brush cytology was 58.5%. The diagnostic yield was higher for proximal than for distal CBD strictures (67 vs. 50%; p = 0.047). It was also higher for females (58 vs. 57.6%; p = 0.94), patients >50 years (60 vs. 50%; p = 0.29) and those with a CA 19.9 level >300 IU/ml (59.4 vs. 55.5%; p = 0.65) but did not reach statistical significance for any of these parameters. Complete follow-up data were available for 96 patients and 46 patients were lost to follow-up. The sensitivity, specificity, positive predictive value and negative predictive value were 65.3, 100, 100 and 27%, respectively. When patients with atypia were included in the group with positive results, the diagnostic yield increased to 65.5% with a diagnostic sensitivity of 68.6%. There were 27 false-negative diagnoses, 10 patients were true-negative and no patients had a false-positive diagnosis. Conclusion: Biliary brush cytology is a safe and simple initial diagnostic procedure in patients with biliary strictures and can be performed at the time of therapeutic ERCP. If performed correctly and then interpreted by a dedicated cytopathologist, it has a good diagnostic yield and sensitivity. We feel that the low rates of success with this technique reported in some earlier studies have led to a feeling that this is not a particularly useful technique. We recommend that this topic should be revisited, and that the technique should be used more often.


2010 ◽  
Vol 156 (5) ◽  
pp. 771-776.e1 ◽  
Author(s):  
Julie Beucher ◽  
Emmanuelle Leray ◽  
Eric Deneuville ◽  
Monique Roblin ◽  
Isabelle Pin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document