Immunoscintigraphy with 131I or 111In Labelled OC 125 F(ab')2 Fragments in Patients with Ovarian Carcinoma

1990 ◽  
Vol 5 (4) ◽  
pp. 159-165 ◽  
Author(s):  
A. Jiménez-Vicioso ◽  
M. Torres ◽  
A. Jiménez-Heffernan ◽  
M.D. Grana ◽  
J.M. Latre ◽  
...  

To evaluate the clinical usefulness of immunoscintigraphy with OC 125 in ovarian carcinoma, we studied 25 patients suspected of having ovarian carcinoma or in follow-up after surgery. Fourteen patients were studied with 131I-OC 125 F(ab')2 and 11 with 111In-OC 125 F(ab')2. No differences were observed with the use of either radionuclide. Global diagnostic indexes obtained were S = 100%, Sp = 44,5% and A = 81%. The low specificity obtained was remarkable: 5 false positive results in two uterine myomas, one abscess, one follicular cyst and one granulation tissue scar. On the other hand, all lesions of ovarian carcinoma were detected. Analysis of the evolution of tumor/background (T/B) uptake ratios from the first to the second day of exploration revealed a tendency for the ratio to diminish significantly (> 15%) in false positive cases with the exception of the abscess while this did not happen in true positive cases, with the exception of a regional recurrence. Analysis of T/B ratio variations could contribute towards elevating the test's specificity.

2011 ◽  
Vol 26 (2) ◽  
pp. 94-101 ◽  
Author(s):  
Delphine Vezzosi ◽  
Thomas Walter ◽  
Agnès Laplanche ◽  
Jean Luc Raoul ◽  
Clarisse Dromain ◽  
...  

Background Multiple causes of false-positive chromogranin A (CgA) measurement have been reported that may affect its impact as a surrogate marker of RECIST progression in well-differentiated gastroenteropancreatic neuroendocrine tumors (WDGEPNET). Aims 1) To evaluate the frequency of false-positive CgA results. 2) To prospectively compare CgA variations with RECIST morphological changes in patients without known causes of false-positive CgA measurements. Methods First, the conditions responsible for potentially false-positive CgA measurements were screened in 184 consecutive patients with metastatic WDGEPNET. Secondly, a variation in CgA at a 6-month interval was compared to RECIST results at 6 months in 46 patients. Results Among 184 patients, elevated CgA was found in 130 cases (71%) including 99 patients with at least one cause of a false-positive result. Impaired kidney function as well as medication with proton pump inhibitors were found to be the 2 major causes of false-positive results. The sensitivity and specificity of CgA measurements compared with morphological tumor changes according to the RECIST criteria were 71% and 50%, respectively, at 6 months. Conclusion Routine screening for the causes of false-positive CgA measurements is mandatory in WDGEPNET patients. Our study does not validate the use of CgA as a surrogate marker of tumor progression.


2014 ◽  
Vol 61 (4) ◽  
pp. 293-299 ◽  
Author(s):  
T. Rosseel ◽  
B. Pardon ◽  
K. De Clercq ◽  
O. Ozhelvaci ◽  
S. Van Borm

1994 ◽  
Vol 10 (1) ◽  
pp. 33-40 ◽  
Author(s):  
Jane Wardle ◽  
Amanda Pernet ◽  
William Collins ◽  
Thomas Bourne

PEDIATRICS ◽  
1976 ◽  
Vol 58 (4) ◽  
pp. 508-512
Author(s):  
Jay Y. Gillenwater ◽  
Charles H. Gleason ◽  
Jacob A. Lohr ◽  
Donald Marion

Bacteriuria screening on 289 children was performed by their parents by means of a self-administered dip-strip culture which was inoculated, incubated, and interpreted in the home. Simultaneous pour-plate quantitative cultures and laboratory-tested dip-strip cultures were done on the same urine specimen which had been tested at home. The dip-strip culture was reliable (89%) in detecting significant bacteriuria with home administration and interpretation. Only 1.6% false-positive results occurred in the home testing. The dip-strip home cultures are an effective way for screening or follow-up of patients with bacteriuria.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 5014-5014
Author(s):  
Silvia Cantoni ◽  
Erika Ravelli ◽  
Maria Cristina Moioli ◽  
Chiara Rusconi ◽  
Vittorio Ruggero Zilioli ◽  
...  

Abstract Abstract 5014 Introduction Risk of developing non Hodgkin lymphomas (NHL) is known to be increased among patients (pts) infected by HIV-1 and sporadic non-HIV related cases of Hodgking lymphomas (HL) are also described. HIV-positive pts also feature a virus-related systemic lymphoadenopathy which makes nodal involvement by lymphoma difficult to evaluate using conventional imaging. The role of positron-emission tomography using 18F-fluorodeoxyglucose (FDG-PET) in the staging and evaluation of response to treatment of pts with NHL and HL is well established in immunocompetent pts, while only limited information is available on lymphomas arising in the setting of HIV infection. We report on a retrospective analysis of FDG-PET results in a group of HIV pts with lymphoma, both NHL and HL, followed-up at our hospital. Patients and methods Twelve HIV-positive male pts with a diagnosis of lymphoma (7 high grade and 1 follicular NHL, 4 HL) underwent a total of 22 PET scans. PET results were compared with those obtained by computed tomography (CT). Nine PET were performed at staging, 7 at restaging following chemotherapy, and 6 at follow-up. At diagnosis of lymphoma: median CD4 count was 200 cells/mcL (range 98-451); HIV genome was undetectable in 5/9 pts, in the remaining 4 pts for whom the data was available viral loads ranged from 103 to 1,452,720 copies/mL; 10/12 pts were already receiving HAART, while the remaining 2 pts started treatment upon diagnosis of lymphoma. Results In the majority of cases (17/22 = 77%) results of PET, CT scan and clinical status were concordant, being diagnostic of either lymphoma presence (11/17) or absence (6/17). No false positive results were recorded at follow-up. In 5/22 cases (23%) PET and CT scan were discordant. In 4 cases PET yielded a false negative result; in 2 cases at diagnosis (2 pts with HL) and in 2 cases at follow-up (both in the pt with follicular lymphoma). In the remaining case, a PET-negative CT-positive adenopathy was demonstrated which proved to be reactive in nature at biopsy. Discussion Our results suggest that FDG-PET is useful in the evaluation of lymphoma in the setting of HIV infection, similarly to what has been observed among immunocompetent pts. Although the number of patients is limited, in our experience PET proved to be able to discriminate between reactive and lymphomatous involvement of lymphoid tissue as demonstrated by absence of false positive results in pts evaluated at follow-up. These results need to be confirmed by larger clinical trials. Disclosures No relevant conflicts of interest to declare.


2017 ◽  
Vol 132 (3) ◽  
pp. 270-274 ◽  
Author(s):  
N Seymour ◽  
G Burkill ◽  
M Harries

AbstractObjectives:Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography.Methods:Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients’ notes and laryngoscopy results were analysed.Results:Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results.Conclusion:Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.


2016 ◽  
Vol 60 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Shafqat Mehmood ◽  
Asif Loya ◽  
Muhammed Aasim Yusuf

Purpose: To evaluate the diagnostic yield of biliary brush cytology and the factors affecting positive results in patients with biliary strictures. Patients and Methods: The medical records of all patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) with biliary brush cytology at our institution from November 2004 to December 2013 were reviewed in this retrospective study. The yield of positive brush cytology and the factors affecting positive yield, such as stricture location, age, gender and preprocedure CA 19.9 level were assessed. The final histopathology, diagnosis obtained by other methods, such as endoscopic ultrasound-guided fine-needle aspiration cytology, CT scan, Tru-Cut biopsy and/or clinical/radiological follow-up were used to identify true- and false-positive/negative results. The brush cytology results were divided into 4 main categories: malignant, benign, atypical cells and inadequate. Results: A total of 1,168 patients underwent ERCP during this 9-year period. Out of these, 142 patients had ERCP and biliary brushings for diagnosis. The mean age of the patients at presentation was 58.7 years (range 23-84 years; 64.8% males). The indication for referral was obstructive jaundice in all patients. Of the 142 patients, 77 (54.2%) had a distal common bile duct (CBD) stricture and 65 (45.8%) had a proximal /complex hilar stricture. The strictures were classified as proximal or distal, based on their relationship with the cystic duct; those below the cystic duct insertion were classified as distal and those above it were considered proximal. The diagnostic yield of brush cytology was 58.5%. The diagnostic yield was higher for proximal than for distal CBD strictures (67 vs. 50%; p = 0.047). It was also higher for females (58 vs. 57.6%; p = 0.94), patients >50 years (60 vs. 50%; p = 0.29) and those with a CA 19.9 level >300 IU/ml (59.4 vs. 55.5%; p = 0.65) but did not reach statistical significance for any of these parameters. Complete follow-up data were available for 96 patients and 46 patients were lost to follow-up. The sensitivity, specificity, positive predictive value and negative predictive value were 65.3, 100, 100 and 27%, respectively. When patients with atypia were included in the group with positive results, the diagnostic yield increased to 65.5% with a diagnostic sensitivity of 68.6%. There were 27 false-negative diagnoses, 10 patients were true-negative and no patients had a false-positive diagnosis. Conclusion: Biliary brush cytology is a safe and simple initial diagnostic procedure in patients with biliary strictures and can be performed at the time of therapeutic ERCP. If performed correctly and then interpreted by a dedicated cytopathologist, it has a good diagnostic yield and sensitivity. We feel that the low rates of success with this technique reported in some earlier studies have led to a feeling that this is not a particularly useful technique. We recommend that this topic should be revisited, and that the technique should be used more often.


2010 ◽  
Vol 156 (5) ◽  
pp. 771-776.e1 ◽  
Author(s):  
Julie Beucher ◽  
Emmanuelle Leray ◽  
Eric Deneuville ◽  
Monique Roblin ◽  
Isabelle Pin ◽  
...  

2020 ◽  
Author(s):  
Sam Sedaghat ◽  
Maya Sedaghat ◽  
Jens Meschede ◽  
Olav Jansen ◽  
Marcus Both

Abstract Background: To assess the long-term diagnostic accuracy of MRI for detecting recurrent soft-tissue sarcoma at a multidisciplinary sarcoma center.Methods: In all, 1055 postoperative follow-up MRIs of 204 patients were included in the study. MRI follow-up scans were systematically reviewed for true-positive/-negative and false-positive/-negative results in detecting recurrent tumor. Available pathological reports and follow-up MRIs were set as reference. Results: The median age of the patients was 55.3±18.2 years. Of the patients, 34.8% presented with recurrences. Here, 65 follow-up scans were true positive, 23 false positive, 6 false negative, and 961 true negative. The overall sensitivity and specificity of MRI for detecting recurrences were 92% and 98%, respectively, with an accuracy of 97%. For intramuscular lesions and after surgery alone the sensitivity was higher (95% and 97%) than for subcutaneous lesions and surgery with additional radiation therapy (83% and 86%, respectively), at similarly high specificities (96-98%). The 6 false-negative results were found in streaky (n=2) and small ovoid/nodular (n=4) recurring lesions. The false-positive lesions imitated streaky (n=14), ovoid/nodular (n=8), and polycyclic/multilobulated recurring tumors (n=1). All false-positive results were found in patients in whom the primary tumors were polycyclic/multilobulated in appearance.Conclusion: MRI shows a high diagnostic accuracy for detecting recurrent STS, with a high sensitivity and specificity. The diagnostic accuracy decreases in subcutaneous lesions and after surgery with radiation therapy, compared to intramuscular lesions and surgery alone. Radiologists should pay particular attention to streaky and small ovoid/nodular recurring lesions and patients with polycyclic/multilobulated primary tumors.


2013 ◽  
Vol 28 (3) ◽  
pp. 313-317 ◽  
Author(s):  
Maria T. Sandri ◽  
Michela Salvatici ◽  
Cristian Mauro ◽  
Davide Radice ◽  
Paola Lentati ◽  
...  

Since squamous cell carcinoma antigen (SCC-Ag) testing became commercially available on the Architect platform, the previously established method on the Abbott IMx platform has been progressively replaced. Aim of this work was to compare SCC-Ag values obtained with the 2 methods. Clinical and laboratory data of 188 patients for whom SCC-Ag determination was requested, were reviewed. IMx was used to determine the levels of SCC-Ag from June 2007 to May 2009, while the Architect system was used from June 2009 to April 2011. Only patients consistently diagnosed with no evidence of disease, for whom at least 2 determinations with each analyzer were available were used. Comparison of the results obtained with the 2 systems was then performed. Mean values for SCC-Ag were 0.56 ng/mL (Standard Error (SE): 0.08) with the IMx method, and 1.08 ng/mL (SE 0.10) with Architect (p<0.0001). False positive results were found in 4.8% of patients with the IMx method and in 9.5% of patients with Architect (p=0.049). The values of SCC-Ag determined on the Architect platform are higher than those obtained on the IMx, with a higher percentage of false positive results.


Sign in / Sign up

Export Citation Format

Share Document