scholarly journals The efficacy and safety of a novel method of peritoneal dialysis catheter insertion from the McBurney point

2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Kyohei Ogawa ◽  
Yukio Maruyama ◽  
Nanae Matsuo ◽  
Yudo Tanno ◽  
Ichiro Ohkido ◽  
...  

Abstract Background Catheter dysfunction, especially omental wrapping, is a serious complication of peritoneal dialysis (PD). Although catheter implantation at a lower site was reported to prevent omental wrapping, this method could induce insufficient drainage of the PD solution and cause pain or a persistent desire to defecate, when the intraperitoneal catheter is of insufficient length or when its tip is in direct contact with the pelvic floor, respectively. The aim of this study was to assess the efficacy and safety of a novel PD catheter insertion method of approaching from the McBurney point, from the outer side of the abdomen. Methods This retrospective study included 23 patients with end-stage renal disease who were started on PD from January 2017 to July 2018 at Ashikaga Red Cross Hospital, Tochigi, Japan. Among them, 16 patients underwent a PD catheter insertion using a conventional method, whereas 7 patients underwent a novel method of approaching from the McBurney point. Infectious and mechanical complications were evaluated until August 2020. Results There were 18 men and 5 women, with a mean age of 63.1 ± 13.6 years. All patients were followed up postoperatively for a mean duration of 27.2 ± 13.4 months. No patient experienced omental wrapping, insufficient drainage of the PD solution, and pain or persistent desire to defecate in both groups. Both the incidence of infectious and mechanical complications (times per patient-year) were not statistically different between patients undergoing a conventional and a novel PD catheter insertion (0.18 vs. 0.24; p = 0.79 and 0.03 vs. 0.16; p = 0.16, respectively). Conclusions This novel method of PD catheter insertion from the McBurney point was safe, caused less discomfort, and was effective in preventing catheter dysfunction.

2014 ◽  
Vol 34 (1) ◽  
pp. 49-56 ◽  
Author(s):  
Yaorong Liu ◽  
Lin Zhang ◽  
Aiwu Lin ◽  
Zhaohui Ni ◽  
Jiaqi Qian ◽  
...  

ObjectivesPeritoneal dialysis (PD) is one of the first-line modalities of renal replacement therapy in patients with end-stage renal disease. Guidelines recommended a break-in period of at least 2 weeks before full PD start. However, the optimal duration of the break-in period is still unclear. In the present study, we investigated the effect of various break-in periods on short-term outcomes in patients on PD.MethodsAll patients who underwent Tenckhoff catheter implantation and initiated PD in Renji Hospital, Shanghai Jiao Tong University School of Medicine, between 1 January 2001 and 31 December 2010 were included. Patients were grouped according to the duration of their break-in period: 7 days or less (BI≤7), 8 - 14 days (BI814), and more than 14 days (BI>14). Kaplan-Meier curves and log-rank tests were used to compare short-term outcomes in the various groups.ResultsOur study enrolled 657 patients (44.5% men), of whom 344, 137, and 176 patients were in the respective break-in groups. Compared with BI>14patients, BI≤7patients had a lower estimated glomerular filtration rate (5.34 ± 1.86 mL/min/1.73 m2vs 6.55 ± 1.71 mL/min/1.73 m2, p < 0.001) and lower serum albumin (33.29 ± 5.36 g/L vs 36.64 ± 5.40 g/L, p < 0.001). The incidence of mechanical complications during the first 6 months was significantly higher in BI≤7patients than in BI>14patients (8.4% vs 1.7%, p = 0.004). However, we observed no significant differences between the three groups with respect to the prevalence of catheter dysfunction requiring surgical intervention ( p > 0.05). Logistic regression analysis showed that BI≤7[relative risk: 4.322; 95% confidence interval (CI): 1.278 to 14.608; p = 0.019] was an independent predictor of catheter dysfunction, but not of catheter dysfunction requiring surgical intervention ( p > 0.05). Catheter dysfunction [hazard ratio (HR): 20.087; 95% CI: 7.326 to 55.074; p < 0.001] and peritonitis (HR: 4.533; 95% CI: 1.748 to 11.751; p = 0.002) were risk factors for technique failure during the first 6 months, but BI≤7was not correlated with technique failure.ConclusionsPatients starting PD with a break-in period of less than 1 week might experience a minor increased risk of mechanical complications, but no major effect on technique survival.


2021 ◽  
Vol 8 ◽  
pp. 205435812098626
Author(s):  
Mark Canney ◽  
Lee Er ◽  
John Antonsen ◽  
Michael Copland ◽  
Rajinder Suneet Singh ◽  
...  

Background: Due to inherent challenges in maintaining physical distancing in hemodialysis units, the Canadian Society of Nephrology has recommended peritoneal dialysis as the preferred modality for patients requiring maintenance dialysis during the coronavirus disease 19 (COVID-19) pandemic. However, pursuing peritoneal dialysis is not without risk due to the requirement for in-person contact during catheter insertion and training, and there is a paucity of data regarding the experience of peritoneal dialysis during the early phases of the pandemic. Objective: To examine the incidence and outcomes of peritoneal dialysis between March 17 and June 01, 2020 compared to the same time period in preceding years. Design: Retrospective observational study. Setting: British Columbia, Canada. After the pandemic was declared on March 17, 2020, patients continued to be trained in peritoneal dialysis. In an effort to limit time spent in hospital, patients were preferentially trained in continuous ambulatory peritoneal dialysis, training times were truncated for some patients, and peritoneal dialysis catheters were inserted by a physician at the bedside whenever feasible. Patients: All patients aged >18 years who started chronic maintenance dialysis during the period March 17 to June 01 in the years 2018 to 2020 inclusive. The time period was extended to include the years 2010 to 2020 inclusive to evaluate longer term trends in dialysis incidence. Measurements: A provincial clinical information system was used to capture the date of commencing dialysis, dialysis modality, and complications including peritonitis. Overall uptake of peritoneal dialysis included new starts and transitions to peritoneal dialysis from in-center hemodialysis during the observation period. Methods: The incidence of dialysis during the specified time period, overall and by modality, was calculated per million population using census figures for the population at risk. Patients were followed for a minimum of 30 days from the start of peritoneal dialysis to capture episodes of peritonitis and COVID-19. Results: A total of 211 patients started maintenance dialysis between March 17 and June 01, 2020. The incidence dialysis rate (41.3 per million population) was lower than that expected based on the 10-year trend from 2010 to 2019 inclusive (expected rate 45.7 per million population, 95% confidence interval 41.7 to 50.1). A total of 93 patients started peritoneal dialysis, including 32 patients who transitioned from in-center hemodialysis, contributing to a higher overall uptake of peritoneal dialysis compared to preceding years. The incidence rate for peritoneal dialysis of 18.2 per million population was higher than that expected (16.3 per million population, 95% confidence interval 14.0 to 19.0). Half of patients (48%) underwent a bedside peritoneal dialysis catheter insertion by a physician. During 30 days of follow-up, 2 (2.2%) patients experienced peritonitis and no patients were diagnosed with COVID-19. Limitations: Results are short term and generalizable only to regions with similarly low community rates of transmission of severe acute respiratory syndrome coronavirus 2. Conclusions: These preliminary findings indicate that peritoneal dialysis can be safely started and perhaps expanded as a means of mitigating the anticipated surge in in-center hemodialysis during the COVID-19 pandemic. Important contributors to the uptake of peritoneal dialysis in British Columbia were bedside catheter insertions and expediting transitions from in-center hemodialysis to peritoneal dialysis.


2019 ◽  
Vol 2 (4) ◽  
pp. 193-200
Author(s):  
Bénédicte Larivière-Durgueil ◽  
Rémi Boudet ◽  
Marie Essig ◽  
Stéphane Bouvier ◽  
Ali Abdeh ◽  
...  

Objective: To assess the recurrence of PD catheter migration after the introduction of a walnut ballast. Materials and Methods: Retrospective study from 1999 to 2014 of PD patients followed in Limousin. Were compared two groups: ballast group (patients who benefited from the establishment of stainless steel ballast at the intraperitoneal catheter extremity) with 26 patients and control group with 204 patients. The primary endpoint was the occurrence of an episode catheter’s migration after ballast’s establishment. Secondary objectives were (i) to determine the causal factors leading to the catheter weighting, (ii) to ensure the safety of the procedure on the following criteria: infectious complications, mechanicals complications, epurations criteria, and catheter’s survival. Results: More than one year after the implementation of the ballast, no recurrent migration was observed in 86.6% of cases. It wasn’t found an increased risk of infections (OR = 0.5, 95% CI [0.22, 1.13]) or mechanical complications (OR = 1.77- 95% CI [0.77, 4.05]) between the two groups. The adequation criteria were similar: KT / V total : 2.37 in the control group and 2.28 in the ballast group (p = 0.63). The survival of the ballast catheter was comparable among the two groups (p = 0.983). Three causal factors that led to the ballast were identified: automated peritoneal dialysis (APD) (OR = 0.38, 95% CI [0.16, 0.9]), the failure from the first use of the catheter (OR = 19.48, CI 95 % [7.67, 49.48]) and the incarceration of the omentum (OR = 15.84, 95% CI [5.81, 43.21]). Conclusion: The ballast used in these study appears to prevent recurrence of migration, without any impact in terms of infectious or mechanical complications, or on the dialysis criteria or on catheter’s survival. However this catheter does currently not have an EC authorization


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Masaaki Nakayama ◽  
Chieko Hamada ◽  
Keitaro Yokoyama ◽  
Yudo Tanno ◽  
Nanae Matsuo ◽  
...  

Abstract The ability to visualize intraluminal surface of peritoneal dialysis (PD) catheter and peritoneal cavity could allow elucidation of the cases of outflow problems, and provide information on changes to the peritoneal membrane leading to encapsulating peritoneal sclerosis. A non-invasive examination that allows those monitoring in need is desirable. We have developed a disposable ultra-fine endoscope that can be inserted into the lumen of the existing PD catheter, allowing observation of the luminal side of the catheter and peritoneal cavity from the tip of the PD catheter, with minimum invasion in practice. In a pre-clinical study in pigs and a clinical study in 10 PD patients, the device provided detailed images, enabling safe, easy observation of the intraluminal side of the entire catheter, and of the morphology and status of the peritoneal surface in the abdominal cavity under dwelling PD solution. Since this device can be used repeatedly during PD therapy, clinical application of this device could contribute to improved management of clinical issues in current PD therapy, positioning PD as a safer, more reliable treatment modality for end-stage renal disease.