Performance of above ground floor CLT wall systems and connections under monotonic loading

Author(s):  
C. Hughes ◽  
D. McPolin ◽  
P. McGetrick ◽  
D. McCrum
2003 ◽  
Vol 94 (11) ◽  
pp. 1228-1233 ◽  
Author(s):  
Indranil Chattoraj ◽  
Anil Kumar ◽  
Swapan K. Das ◽  
Mita Tarafder ◽  
Soumitra Tarafder

2021 ◽  
Vol 234 ◽  
pp. 111968
Author(s):  
Jorge Rocha ◽  
Eduardo Pereira ◽  
José Sena-Cruz ◽  
Luís Valarinho ◽  
João Ramôa Correia

2021 ◽  
Vol 13 (7) ◽  
pp. 1273
Author(s):  
Lapo Miccinesi ◽  
Alessandra Beni ◽  
Silvia Monchetti ◽  
Michele Betti ◽  
Claudio Borri ◽  
...  

This paper reports the results of a ground penetrating radar (GPR) survey of the ground-floor of Academia Gallery (Florence, Italy) where the Michelangelo’s David is exhibited to the public. The equipment used was a step-frequency GPR operating in the 100 MHz-1 GHz band, named ORFEUS. The survey covered an area of 13 m × 7.3 m, and the scans were performed along two orthogonal directions. Acquisitions in the same direction were separated by 0.25 m from each other. The GPR was able to confirm the underground structure, as it can be deducted by planimetry and historical documentation. In particular, the radar clearly detected the air-conditioning ducts under the floor and an approximately circular foundation below the basement of the statue.


2015 ◽  
Vol 32 (7) ◽  
pp. 2100-2119 ◽  
Author(s):  
Ali Johari ◽  
Jaber Rezvani Pour ◽  
Akbar Javadi

Purpose – Liquefaction of soils is defined as significant reduction in shear strength and stiffness due to increase in pore water pressure. This phenomenon can occur in static (monotonic) or dynamic loading patterns. However, in each pattern, the inherent variability of the soil parameters indicates that this problem is of a probabilistic nature rather than being deterministic. The purpose of this paper is to present a method, based on random finite element method, for reliability assessment of static liquefaction of saturated loose sand under monotonic loading. Design/methodology/approach – The random finite element analysis is used for reliability assessment of static liquefaction of saturated loose sand under monotonic loading. The soil behavior is modeled by an elasto-plastic effective stress constitutive model. Independent soil parameters including saturated unit weight, peak friction angle and initial plastic shear modulus are selected as stochastic parameters which are modeled using a truncated normal probability density function (pdf). Findings – The probability of liquefaction is assessed by pdf of modified pore pressure ratio at each depth. For this purpose pore pressure ratio is modified for monotonic loading of soil. It is shown that the saturated unit weight is the most effective parameter, within the selected stochastic parameters, influencing the static soil liquefaction. Originality/value – This research focuses on the reliability analysis of static liquefaction potential of sandy soils. Three independent soil parameters including saturated unit weight, peak friction angle and initial plastic shear modulus are considered as stochastic input parameters. A computer model, coded in MATLAB, is developed for the random finite element analysis. For modeling of the soil behavior, a specific elasto-plastic effective stress constitutive model (UBCSAND) was used.


2021 ◽  
Author(s):  
Katarzyna Zielonko-Jung ◽  
Justyna Janiak

AbstractThe present study is aimed at the analysis of possibilities for shading southern frontage of street oriented along the E-W axis by the single row of trees, parallel to the southern elevations. The effectiveness of solar control shading was tested depending on the geometric relationships between trees and buildings. Numerical simulation analyses were conducted in Rhinoceros® program for the street located in humid continental climate in city Płock, Poland (52°32′50 “N 19°42’00 “E), for the day of the highest degree of total solar radiation in the year i.e. June 7th, during hours: 8.00a.m - 5.00 p.m. The analysis has proved that a row of 20–25 year old Sycamore Maple ‘Rotterdam’ in the street 30 m wide and 18 m high (H/W = 0.6), can provide solar protection for the southern frontage, especially when trees are located no more than 4 m away. Location of greenery within the range of 4 to 5 m from the buildings leads to a radical reduction in the possibility of shading the wall surfaces (at 5 m to 0%). Over 90% of the shading area of the ground floor façade walls was found when trees were within the distance 2 and 3 m away from the building.


2003 ◽  
Vol 19 (8) ◽  
pp. 1215-1244 ◽  
Author(s):  
F. Barlat ◽  
J.M. Ferreira Duarte ◽  
J.J. Gracio ◽  
A.B. Lopes ◽  
E.F. Rauch

1986 ◽  
Vol 2 (1-4) ◽  
pp. 116-117
Author(s):  
Attila Csepanyi ◽  
Mihaly Sebestyen

The first emergency department in Hungary was established in Hetenyi Geza County Hospital in 1976. It was organized as part of a research program commissioned by the Ministry of Health. Initially, the hospital had 1400 beds which have now increased to 2,000.The Emergency Department is located on the ground floor of a new building and occupies 1,100 square meters of surface. The operation of the department is divided into three main areas.


Sign in / Sign up

Export Citation Format

Share Document