Effect of Manufacturing Process on the Retention of Abuse-Deterrent Properties of PEO-Matrix Tablets

2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Leyla Rezaei ◽  
Saikishore Meruva ◽  
Maureen D. Donovan
Author(s):  
M. Shlepr ◽  
C. M. Vicroy

The microelectronics industry is heavily tasked with minimizing contaminates at all steps of the manufacturing process. Particles are generated by physical and/or chemical fragmentation from a mothersource. The tools and macrovolumes of chemicals used for processing, the environment surrounding the process, and the circuits themselves are all potential particle sources. A first step in eliminating these contaminants is to identify their source. Elemental analysis of the particles often proves useful toward this goal, and energy dispersive spectroscopy (EDS) is a commonly used technique. However, the large variety of source materials and process induced changes in the particles often make it difficult to discern if the particles are from a common source.Ordination is commonly used in ecology to understand community relationships. This technique usespair-wise measures of similarity. Separation of the data set is based on discrimination functions. Theend product is a spatial representation of the data with the distance between points equaling the degree of dissimilarity.


1952 ◽  
Vol 44 (3) ◽  
pp. 449-449
Author(s):  
Rudolph Allgeier ◽  
Reuben Wisthoff ◽  
Frank Hildebrandt

1993 ◽  
Vol 13 (S 01) ◽  
pp. S5-S11 ◽  
Author(s):  
Debra Hoppensteadt ◽  
Jeanine Walenga ◽  
A Ahsan ◽  
O Iqbal ◽  
W Jeske ◽  
...  

SummaryThe introduction of low molecular weight heparins has added a new dimension to the pharmacological management of thrombotic disorders. Because of different chemical and pharmacological characteristics, due to the manufacturing process, each LMWH should be considered as a distinct entitity and only be used for its given indication. A list of commercially available LMWHs is included. The mechanism of action of the LMWHs and their use in various disorders are discussed. Available laboratory tests for monitoring LMWHs are presented and their limitations pointed out.


2012 ◽  
Vol 1 (8) ◽  
pp. 186 ◽  
Author(s):  
Urmi Das ◽  
Mohammad Salim Hossain

<p>Sustained release Carvedilol matrix tablets constituting Kollidon SR were developed in this study in an attempt to investigate the effect of release modifiers on the release profile of Carvedilol from matrix. Three matrix tablet formulations were prepared by direct compression of Kollidon SR in combination with release modifier (HPMC and Microcrystalline Cellulose) and magnesium stearate. Tablets containing only Kollidon SR with the active ingredient demonstrated a rapid rate of drug release. Incorporation of HPMC in the matrix tablet prolonged the release of drug but incorporation of Microcrystalline Cellulose showed superimposable release pattern with an initial burst effect as confirmed by mean dissolution time and Higuchi release rate data. After 7 hours of dissolution, Carvedilol release from the matrix systems were 91.42%, 83.41%, from formulation F1 and F2 respectively. Formulation F3 exhibited 100 % release at 4 hours. All the tablet formulations showed acceptable pharmaco-technical properties and complied with the in-house specifications for tablet weight variation, friability, hardness, thickness, and diameter. Prepared tablets also showed sustained release property for carvedilol. The drug release mechanism from the matrix tablets of F1 and F2 was found to be followed by Fickian and F3 by Non-Fickian mechanism.</p><p>DOI: <a href="http://dx.doi.org/10.3329/icpj.v1i8.11095">http://dx.doi.org/10.3329/icpj.v1i8.11095</a></p> <p>International Current Pharmaceutical Journal 2012, 1(8): 186-192</p>


Author(s):  
Surender Verma ◽  
S. Singh ◽  
D. Mishra ◽  
Atul Gupta ◽  
Rakesh Sharma

The objective of present study was to develop colon targeted drug delivery using bacterially triggered approach through oral route. Valdecoxib (COX-2 inhibitor) was chosen as a model drug in order to target it to colon which may prove useful in inflammatory bowel disease and related disorders. Matrix tablets of Valdecoxib were prepared by wet granulation technique utilizing different ratio of Guar gum and Sodium starch glycholate. The prepared matrix tablets were evaluated for uniformity of weight, uniformity of content, hardness and in vitro dissolution study in simulated gastric and intestinal fluid (Phosphate Buffer pH-1.2, pH-6.8 and pH-7.4), followed by Dissolution study in bio-relevant dissolution media Phosphate Buffer (pH-6.8) containing rat caecal content. The results revealed that the formulated batch had released lesser quantity of drug at pH 1.2 and pH 7.4 in 2 hors whereas in biorelevent dissolution media containing rat caecal content it released significantly higher amount of drug which was also significantly higher than the dissolution media of same pH without caecal content (microflora) and it was concluded that guar gum can be used as a potential carrier for targeting drugs to colon.


Sign in / Sign up

Export Citation Format

Share Document