Video-Assisted Navigation for Adjustment of Image-Guidance Accuracy to Slight Brain Shift

2015 ◽  
Vol 11 (4) ◽  
pp. 504-511 ◽  
Author(s):  
Sven R Kantelhardt ◽  
Angelika Gutenberg ◽  
Axel Neulen ◽  
Naureen Keric ◽  
Mirjam Renovanz ◽  
...  

Abstract BACKGROUND Information supplied by an image-guidance system can be superimposed on the operating microscope oculars or on a screen, generating augmented reality. Recently, the outline of a patient's head and skull, injected in the oculars of a standard operating microscope, has been used to check the registration accuracy of image guidance. OBJECTIVE To propose the use of the brain surface relief and superficial vessels for real-time intraoperative visualization and image-guidance accuracy and for intraoperative adjustment for brain shift. METHODS A commercially available image-guidance system and a standard operating microscope were used. Segmentation of the brain surface and cortical blood vessel relief was performed manually on preoperative computed tomography and magnetic resonance images. The overlay of segmented digital and real operating-microscope images was used to monitor image-guidance accuracy. Adjustment for brain shift was performed by manually matching digital images on real structures. RESULTS Experimental manipulation on a phantom proved that the brain surface relief could be used to restore accuracy if the primary registration shifted. Afterward, the technique was used to assist during surgery of 5 consecutive patients with 7 deep-seated brain tumors. The brain surface relief could be successfully used to monitor registration accuracy after craniotomy and during the whole procedure. If a certain degree of brain shift occurred after craniotomy, the accuracy could be restored in all cases, and corticotomies were correctly centered in all cases. CONCLUSION The proposed method was easy to perform and augmented image-guidance accuracy when operating on small deep-seated lesions.

1994 ◽  
Vol 14 (5) ◽  
pp. 749-762 ◽  
Author(s):  
Jean-François Mangin ◽  
Vincent Frouin ◽  
Isabelle Bloch ◽  
Bernard Bendriem ◽  
Jaime Lopez-Krahe

We propose a fully nonsupervised methodology dedicated to the fast registration of positron emission tomography (PET) and magnetic resonance images of the brain. First, discrete representations of the surfaces of interest (head or brain surface) are automatically extracted from both images. Then, a shape-independent surface-matching algorithm gives a rigid body transformation, which allows the transfer of information between both modalities. A three-dimensional (3D) extension of the chamfer-matching principle makes up the core of this surface-matching algorithm. The optimal transformation is inferred from the minimization of a quadratic generalized distance between discrete surfaces, taking into account between-modality differences in the localization of the segmented surfaces. The minimization process is efficiently performed via the precomputation of a 3D distance map. Validation studies using a dedicated brain-shaped phantom have shown that the maximum registration error was of the order of the PET pixel size (2 mm) for the wide variety of tested configurations. The software is routinely used today in a clinical context by the physicians of the Service Hospitalier Frédéric Joliot (>150 registrations performed). The entire registration process requires ∼5 min on a conventional workstation.


1990 ◽  
Vol 72 (3) ◽  
pp. 433-440 ◽  
Author(s):  
Xiaoping Hu ◽  
Kim K. Tan ◽  
David N. Levin ◽  
Simranjit Galhotra ◽  
John F. Mullan ◽  
...  

✓ Data from single 10-minute magnetic resonance scans were used to create three-dimensional (3-D) views of the surfaces of the brain and skin of 12 patients. In each case, these views were used to make a preoperative assessment of the relationship of lesions to brain surface structures associated with movement, sensation, hearing, and speech. Interactive software was written so that the user could “slice” through the 3-D computer model and inspect cross-sectional images at any level. A surgery simulation program was written so that surgeons were able to “rehearse” craniotomies on 3-D computer models before performing the actual operations. In each case, the qualitative accuracy of the 3-D views was confirmed by intraoperative inspection of the brain surface and by intraoperative electrophysiological mapping, when available.


2012 ◽  
Vol 2012 ◽  
pp. 1-20 ◽  
Author(s):  
Alvaro Valencia ◽  
Benjamin Blas ◽  
Jaime H. Ortega

This study investigates the effects of different solid models on predictions of brain shift for three craniotomies. We created a generic 3D brain model based on healthy human brain and modeled the brain parenchyma as single continuum and constrained by a practically rigid skull. We have used elastic model, hyperelastic 1st, 2nd, and 3rd Ogden models, and hyperelastic Mooney-Rivlin with 2- and 5-parameter models. A pressure on the brain surface at craniotomy region was applied to load the model. The models were solved with the finite elements package ANSYS. The predictions on stress and displacements were compared for three different craniotomies. The difference between the predictions of elastic solid model and a hyperelastic Ogden solid model of maximum brain displacement and maximum effective stress is relevant.


2020 ◽  
Vol 34 (10) ◽  
pp. 4702-4711
Author(s):  
C. Schneider ◽  
S. Thompson ◽  
J. Totz ◽  
Y. Song ◽  
M. Allam ◽  
...  

Abstract Background The laparoscopic approach to liver resection may reduce morbidity and hospital stay. However, uptake has been slow due to concerns about patient safety and oncological radicality. Image guidance systems may improve patient safety by enabling 3D visualisation of critical intra- and extrahepatic structures. Current systems suffer from non-intuitive visualisation and a complicated setup process. A novel image guidance system (SmartLiver), offering augmented reality visualisation and semi-automatic registration has been developed to address these issues. A clinical feasibility study evaluated the performance and usability of SmartLiver with either manual or semi-automatic registration. Methods Intraoperative image guidance data were recorded and analysed in patients undergoing laparoscopic liver resection or cancer staging. Stereoscopic surface reconstruction and iterative closest point matching facilitated semi-automatic registration. The primary endpoint was defined as successful registration as determined by the operating surgeon. Secondary endpoints were system usability as assessed by a surgeon questionnaire and comparison of manual vs. semi-automatic registration accuracy. Since SmartLiver is still in development no attempt was made to evaluate its impact on perioperative outcomes. Results The primary endpoint was achieved in 16 out of 18 patients. Initially semi-automatic registration failed because the IGS could not distinguish the liver surface from surrounding structures. Implementation of a deep learning algorithm enabled the IGS to overcome this issue and facilitate semi-automatic registration. Mean registration accuracy was 10.9 ± 4.2 mm (manual) vs. 13.9 ± 4.4 mm (semi-automatic) (Mean difference − 3 mm; p = 0.158). Surgeon feedback was positive about IGS handling and improved intraoperative orientation but also highlighted the need for a simpler setup process and better integration with laparoscopic ultrasound. Conclusion The technical feasibility of using SmartLiver intraoperatively has been demonstrated. With further improvements semi-automatic registration may enhance user friendliness and workflow of SmartLiver. Manual and semi-automatic registration accuracy were comparable but evaluation on a larger patient cohort is required to confirm these findings.


2002 ◽  
Vol 2 (4) ◽  
pp. 323-329 ◽  
Author(s):  
Ulf Labsik ◽  
Kai Hormann ◽  
Martin Meister ◽  
Gu¨nther Greiner

The extraction and display of iso-surfaces is a standard method for the visualization of volume data sets. In this paper we present a novel approach that utilizes a hierarchy on both the input and the output data. For the generation of a coarse base mesh, we construct a hierarchy of volumes and extract an iso-surface from the coarsest resolution with a standard Marching Cubes algorithm. We additionally apply a simple mesh decimation algorithm to improve the shape of the triangles. We iteratively fit this mesh to the iso-surface at the finer volume levels. To be able to reconstruct fine detail of the iso-surface we thereby adaptively subdivide the mesh. To evenly distribute the vertices of the triangle mesh over the iso-surface and generate a triangle mesh with evenly shaped triangles, we have integrated a mesh smoothing algorithm into the fitting process. The advantage of this approach is that it generates a mesh with subdivision connectivity which can be utilized by several multiresolution algorithms such as compression and progressive transmission. As applications of our method we show how to reconstruct the surface of archeological artifacts and the reconstruction of the brain surface for the simulation of the brain shift phenomenon.


Author(s):  
Wen Li ◽  
Nancy C. Andreasen ◽  
Peg Nopoulos ◽  
Vincent A. Magnotta

Author(s):  
R.G. Frederickson ◽  
R.G. Ulrich ◽  
J.L. Culberson

Metallic cobalt acts as an epileptogenic agent when placed on the brain surface of some experimental animals. The mechanism by which this substance produces abnormal neuronal discharge is unknown. One potentially useful approach to this problem is to study the cellular and extracellular distribution of elemental cobalt in the meninges and adjacent cerebral cortex. Since it is possible to demonstrate the morphological localization and distribution of heavy metals, such as cobalt, by correlative x-ray analysis and electron microscopy (i.e., by AEM), we are using AEM to locate and identify elemental cobalt in phagocytic meningeal cells of young 80-day postnatal opossums following a subdural injection of cobalt particles.


2005 ◽  
Vol 25 (1_suppl) ◽  
pp. S543-S543
Author(s):  
Satoshi Kimura ◽  
Keigo Matsumoto ◽  
Yoshio Imahori ◽  
Katsuyoshi Mineura ◽  
Toshiyuki Itoh

Author(s):  
Preecha Yupapin ◽  
Amiri I. S. ◽  
Ali J. ◽  
Ponsuwancharoen N. ◽  
Youplao P.

The sequence of the human brain can be configured by the originated strongly coupling fields to a pair of the ionic substances(bio-cells) within the microtubules. From which the dipole oscillation begins and transports by the strong trapped force, which is known as a tweezer. The tweezers are the trapped polaritons, which are the electrical charges with information. They will be collected on the brain surface and transport via the liquid core guide wave, which is the mixture of blood content and water. The oscillation frequency is called the Rabi frequency, is formed by the two-level atom system. Our aim will manipulate the Rabi oscillation by an on-chip device, where the quantum outputs may help to form the realistic human brain function for humanoid robotic applications.


Sign in / Sign up

Export Citation Format

Share Document