scholarly journals Treatment of Isolated Lateral Malleolar Fractures Using Locking Compression Plate Fixation and Tension Band Wiring Fixation

2020 ◽  
Vol 33 (1) ◽  
pp. 16
Author(s):  
Woojin Shin ◽  
Seondo Kim ◽  
Jiyeon Park
Injury ◽  
2020 ◽  
Vol 51 (7) ◽  
pp. 1597-1602
Author(s):  
Patrick Goetti ◽  
Dominique Andre Behrends ◽  
Nicolas Gallusser ◽  
Alexandre Terrier ◽  
Fabio Becce ◽  
...  

2010 ◽  
Vol 131 (1) ◽  
pp. 85-91 ◽  
Author(s):  
Philipp Henle ◽  
Kevin Ortlieb ◽  
Kerstin Kuminack ◽  
Christof A. Mueller ◽  
Norbert P. Suedkamp

2009 ◽  
Vol 22 (04) ◽  
pp. 1-8 ◽  
Author(s):  
O. Lanz ◽  
R. McLaughlin ◽  
S. Elder ◽  
S. Werre ◽  
D. Filipowicz

Summary3.5 locking compression plate (LCP) fixation was compared to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model. Thirty paired humeri from adult, large breed dogs were separated into equal groups based on testing: static compression, cyclic compression, and cyclic torsion. Humeral constructs stabilized with LCP were significantly stiffer than those plated with LCDCP when loaded in static axial compression (P = 0.0004). When cyclically loaded in axial compression, the LCP constructs were significantly less stiff than the LC-DCP constructs (P = 0.0029). Constructs plated with LCP were significantly less resistant to torsion over 500 cycles than those plated with LC-DCP (P<0.0001). The increased stiffness of LCP constructs in monotonic loading compared to constructs stabilised with non-locking plates may be attributed to the stability afforded by the plate-screw interface of locking plates. The LCP constructs demonstrated less stiffness in dynamic testing in this model, likely due to plate-bone offset secondary to non-anatomic contouring and occasional incomplete seating of the locking screws when using the torque-limiting screw driver. Resolution of these aspects of LCP application may help improve the stiffness of fixation in fractures modeled by the experimental set-up of this investigation.


Author(s):  
Lokesh Kumar Yogi ◽  
Gagandeep Mahi ◽  
C. R. Thorat ◽  
Moti Janardhan Naik

<p><strong>Background:</strong> Fractures of olecranon are common fractures in upper limb. Tension band wiring (TBW) and plate fixation (PF) are mostly used techniques but choice is based on type of fracture and surgeon’s preference.</p><p><strong>Methods:</strong>  A study assessed functional results in 28 patients that were enrolled after the clinical event of trauma has occurred. Patients were divided into two groups- Group (A) for TBW and Group (B) for PF; here gender, age and side of fracture were ignored. Post-operative functional outcome were evaluated by using the Mayo Elbow Performance (MEP) and the Disabilities of the Arm, Shoulder and Hand (DASH) score parameters.</p><p><strong>Results:<em> </em></strong>Mean (SD) union time as determined by postoperative radiographs was 8.5 (1.48) weeks for group (A) and 9 (2.08) weeks for group (B). Mean (SD) MEP score at 9 months in group (A) 84.28 (7.28) and 80.71 (10.92) in group (B). Mean (SD) DASH at 9 months in group (A) 12.2 (8.8) and 11.7 (10.4) in group (B). Complications were reported in group (A) 6 patient (42.85%) out of 14 patients and in group (B) 1 patient (7.14%) out of 14 patients.</p><p><strong>Conclusions:<em> </em></strong>The current study shows that there are no significant differences in functional outcome between both the study groups. Due to lesser complications, we recommend the plate fixation approach as the better choice for transverse displaced olecranon fractures. More large scale studies are required to further confirm our results.</p>


Sign in / Sign up

Export Citation Format

Share Document