scholarly journals Design of a Smart Safety Measurement System Using Bluetooth Beacon Sensor Nodes

2017 ◽  
Vol 21 (1) ◽  
pp. 126-131 ◽  
Author(s):  
Young-soo Park ◽  
Chang-jin Park ◽  
Sun-hee Cho ◽  
Kyoung-yong Park ◽  
Min-sun Kim ◽  
...  
Electronics ◽  
2019 ◽  
Vol 8 (10) ◽  
pp. 1085 ◽  
Author(s):  
Amir Bashian ◽  
Mohsen Assili ◽  
Amjad Anvari-Moghaddam ◽  
João P. S. Catalão

Real-time monitoring of the power system by phasor measurement units (PMUs) leads to the development of such devices in a wide area measurement system (WAMS). However, the power system observability cannot be obtained by employing only PMUs. The communication infrastructure (CI) is a significant part of the WAMS that has to be optimally designed and implemented to collect data from PMUs and deliver them to control centers. In this paper, a novel hybrid wireless sensor network is proposed for the connection of PMUs throughout the system to enable convenient and low-cost communication media. The problem of observability in the communication system is checked along with the optimal placement of PMUs in the power system to reach full observability. A hybrid wireless sensor network including plug-in powered sensor nodes (PPSNs) and energy harvesting sensor nodes (EHSNs) is utilized for increasing the reliability of the communication system. In the proposed co-optimal PMU-sensor placement problem, the main objective is to minimize the total cost of PMU placement and the related communication system, considering full observability of the power system and CI. To achieve better results, the zero-injection bus (ZIB) effect and system observability redundancy index (SORI) are considered as a constraint in the objective function. A binary-coded genetic algorithm is used for solving the proposed mixed-objective optimization problem subject to different technical operating constraints. The proposed method is examined on IEEE 13-bus and IEEE 37-bus test feeder systems. The results show the applicability and effectiveness of the proposed method compared with the conventional methods in this subject area.


MACRo 2015 ◽  
2017 ◽  
Vol 2 (1) ◽  
pp. 105-111
Author(s):  
Loránd Farkas ◽  
Lajos Losonczi

AbstractThe aim of this paper is to present a communication protocol designed for Wireless Sensor Network based biosignal measurement system. The protocol addressees the issue of time synchronization of the measuring nodes and real time transmission of the acquired measurements. We run the Contiki OS on the sensor nodes and the protocol was implemented as a process. The proposed protocol was tested on custom built hardware, developed by our team for biosignal measurement.


Sign in / Sign up

Export Citation Format

Share Document