Effects of Fin Structure on Heat Transfer and Resistance Characteristics of Super Slit Finned Tube Air Cooler

2021 ◽  
Vol 10 (03) ◽  
pp. 639-648
Author(s):  
岩 李
Keyword(s):  
1985 ◽  
Vol 107 (1) ◽  
pp. 198-204 ◽  
Author(s):  
P. W. Eckels ◽  
T. J. Rabas

The heat transfer and pressure drop performance of heat exchangers fabricated from helically wrapped finned tubes with an equilateral triangular pitch arrangement are reported for one through five rows. Two finned tube types were tested, one with a “T” foot and the other with an overlapped “L” foot. The dimensions of both finned tubes were similar and were typical of those used in air-cooling applications. The tube diameter was 25.4 mm; the fin height was 15.87 mm; the fin number was 0.41/mm; and the fin-tip clearance was 6.35 mm. The fin base thickness was 0.38 mm and was tapered to half the base thickness at the fin outside diameter. No difference in the thermal performance of the two finned tube types could be detected. Both the heat transfer coefficient and pressure drop were found to increase with the number of tube rows. These results were then compared to other published data.


2018 ◽  
Vol 49 (17) ◽  
pp. 1705-1720 ◽  
Author(s):  
Qing Zhang ◽  
Xuesheng Wang ◽  
Weicheng Ruan ◽  
Qinzhu Chen ◽  
Zilong Liu

Author(s):  
Felipe Silva dos Santos ◽  
Kamal Ismail ◽  
Fátima Lino

2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


1987 ◽  
Vol 109 (2) ◽  
pp. 388-391 ◽  
Author(s):  
E. M. Sparrow ◽  
M. A. Ansari

Measurements were made of the combined natural convection and radiation heat transfer from a horizontal finned tube situated in a vertical channel open at the top and bottom. In one set of experiments, both walls of the channel were heavily insulated, while in a second set of experiments, one of the insulated walls was replaced by an uninsulated metallic sheet. In general, the heat transfer coefficients were found to be lower with the metal wall in place, but only moderately. With the finned tube situated at the bottom of the channel, the differences in the heat transfer coefficients corresponding to the two types of walls were only a few percent. When the tube was positioned at the mid-height of the channel, larger differences were encountered, but in the practical range of Rayleigh numbers, the differences did not exceed 5 percent.


2011 ◽  
Vol 393-395 ◽  
pp. 412-415
Author(s):  
Jian Hua Zhong ◽  
Li Ming Jiang ◽  
Kai Feng

In this article, finned copper tube used in the central air conditioning was acted as the discussed object. According to the combination with actual processing and theoretical calculations, Five finned tube was selected with typical structural parameters, and established their entity model using Pro/E, then the heat transfer process of finned tube was simulated through the ANSYS, the effect of the fin height, fin thickness and other structure parameters to the heat transfer enhancement of finned tube was researched. Meantime the efficiency of the heat transfer under different convection heat transfer coefficient was also studied.