563 Melting Heat Transfer of Phase Change Material in Horizontal Elliptical Tube Located in Water

2001 ◽  
Vol 2001.14 (0) ◽  
pp. 659-660
Author(s):  
Koichi HIROSE ◽  
Tsukasa YOSHII
Author(s):  
Yu Xu ◽  
Zihang Zhu ◽  
Shugaowa Li ◽  
Jiale Wang

Abstract A numerical investigation on the melting process of paraffin wax RT44 under supergravity (5–20 g) was conducted to evaluate the effect of supergravity on the melting heat transfer characteristics. The simulations were conducted in a horizontally placed container with a constant heat flux of 5–50 kW/m2 maintained on the bottom wall under both supergravity and the earth gravity (1 g). The numerical data under supergravity are compared with those under the Earth gravity for all circumstances. The results indicate that the melting heat transfer characteristics of the phase change material (PCM) are affected by supergravity significantly (around 30%) within 20 g. With the increase of supergravity, the heating wall temperature decreases, and the liquid fraction as well as the melting rate increases. Meanwhile, the variation amplitudes of these melting characteristics decrease gradually until less than 2% at 20 g. The effect of supergravity can be attributed to the intensification of the natural convection due to buoyancy, yielding vortexes in internal flow and fluctuations of solid–liquid interface and temperature field.


2019 ◽  
Vol 111 ◽  
pp. 01001
Author(s):  
Hansol Lim ◽  
Hye-Jin Cho ◽  
Seong-Yong Cheon ◽  
Soo-Jin Lee ◽  
Jae-Weon Jeong

A phase change material based radiant cooling panel with thermoelectric module (PCM-TERCP) is proposed in this study. It consists of two aluminium panels, and phase change materials (PCMs) sandwiched between the two panels. Thermoelectric modules (TEMs) are attached to one of the aluminium panels, and heat sinks are attached to the top side of TEMs. PCM-TERCP is a thermal energy storage concept equipment, in which TEMs freeze the PCM during the night whose melting temperature is 16○C. Therefore, the radiant cooling panel can maintain a surface temperature of 16◦C without the operation of TEM during the day. Furthermore, it is necessary to design the PCM-TERCP in a way that it can maintain the panel surface temperature during the targeted operating time. Therefore, the numerical model was developed using finite difference method to evaluate the thermal behaviour of PCM-TERCP. Experiments were also conducted to validate the performance of the developed model. Using the developed model, the possible operation time was investigated to determine the overall heat transfer coefficient required between radiant cooling panel and TEM. Consequently, the results showed that a overall heat transfer coefficient of 394 W/m2K is required to maintain the surface temperature between 16○C to 18○C for a 3 hours operation.


Sign in / Sign up

Export Citation Format

Share Document