The Sealing Performance Evaluation in tiny leakage region for Bolted Flange Connections with Metallic Flat Gaskets Subject to Internal Pressure.

2016 ◽  
Vol 2016 (0) ◽  
pp. 254
Author(s):  
Koji KONDO ◽  
Koji SATO ◽  
Satomi TAKAHASHI ◽  
Toshiyuki SAWA
2019 ◽  
Vol 795 ◽  
pp. 246-253
Author(s):  
Fa Kun Zhuang ◽  
Xiao Peng Li ◽  
Guo Shan Xie ◽  
Jin Shi ◽  
Yian Wang

Leakage accidents often occur at the bolted flange joints, which are widely used in the petro-chemical plant. This is mainly resulted by the reduction of bolt force during operation. Therefore, bolt force is very important for sealing performance of the joints in service. Based on the leakage rate parameter, the relationship between the bolt force and gasket stress was derived. Moreover, the leakage rate model was established on the basis of bolt force. With this model, the leakage rate can be directly calculated through the bolt force, and the sealing performance can be evaluated. In order to verify this model, corresponding experiments have been performed. It shows that with the internal pressure increasing, the bolt force increases and the gasket stress reduces. There exists a monotonic relationship between the bolt force and gasket stress. The theoretical gasket stress value corresponds well with the experimental value. The calculated leakage rates for the joints also agree well with the experimental value. Then, it is feasible to evaluate the sealing performance for the bolted flange joints based on the bolt force.


Author(s):  
Shinobu Kaneda ◽  
Hirokazu Tsuji

In the past study the plastic region tightening has been applied to the bolted flange joint with smaller nominal diameter and its advantages have been demonstrated, however, behavior of the bolted flange joint with larger diameter is not investigated. Flange rotation of the bolted flange joint with large diameter increases when the internal pressure is applied. Gasket stress is not uniform and it may cause leak accident. So, it is necessary to investigate the behavior of the larger diameter flange. The present paper describes the behavior of bolted flange joint with large diameter under plastic region tightening. Firstly, API 20-inch flange joint tightened to the plastic region by bolt with a smaller diameter and superiority in the uniformity of the axial bolt force is demonstrated. And then the internal pressure is applied to the bolted flange joint and the behavior of the additional axial bolt force is demonstrated. The axial bolt force decreases with increasing the internal pressure, and the load factor is negative due to increasing of the flange rotation. However, the load factor of the bolted flange joint tightened to the plastic region by using the bolt with the smaller diameter approached zero. Using the bolts with smaller diameter is advantageous to the flange joint with the larger diamter, whose load factor is negative, to prevent the leakage. Additionally, the leak rate from the bolted flange joint is measured and the sufficient sealing performance is obtained.


Author(s):  
Tsutomu Kikuchi ◽  
Yuya Omiya ◽  
Toshiyuki Sawa

The effects of nut thinning due to corrosion on the strength characteristic and the sealing performance in 3B bolted flange joints under internal pressure are examined from both FEM calculations and experiments. The following results are obtained. When bolts and nuts in a bolted flange joint are tightened with 50% of yield stress, no yield region at the engaged screw thread occurs, however, when they arc tightened with 90% of the yield stress, a small scale yield region occurs at the roots of the engaged three screw threads from the bearing surface of the nut. While verifying this phenomenon using FEM, it was newly discovered that when the height of the nut was reduced to 1/3 (equivalent to approximately two threads) of the original dimensions according to the standards, the sealing performance could no longer be assured.


Author(s):  
Tsutomu Kikuchi ◽  
Hirokazu Tsuji ◽  
Daichi Tsurumi

In the damage evaluation (and analysis) of the bolted flange joints, it is most important to evaluate the reduction in the sealing performance. Although the marginal nut height found by Alexander’s theory [1] serves as a value smaller about 20% than standard nut height, even if it becomes thin 20% or more on a track record and experience, leakage does not occur. In this study the effects of nut thinning due to corrosion on the sealing performance in 3-inch bolted flange joints under internal pressure by use of FEM calculations. The following results are obtained the relationship between stripping bolt load and nut height is developed, and the marginal nut height for the sealing performance is calculated.


Author(s):  
Koji Kondo ◽  
Shota Tsubaki ◽  
Toshiyuki Sawa ◽  
Tsutomu Kikuchi ◽  
Yuya Omiya

Bolted flange connections with ring joint gaskets have been used to seal the inner fluid under higher internal pressure and higher temperature conditions where soft gaskets such as compressed sheet gaskets cannot be applied. Bolted flange connections are frequently tightened using torque wrench, and it is known that the values of bolt preloads are scattered. The effect of the scatter on the sealing performance for bolted flange connections with compressed sheet gasket or semi-metal gasket has been examined. However, no research on the characteristics for the bolted flange connections with ring joint gasket has been found. It is necessary to know the effect of the scattered bolt preloads on the sealing performance and mechanical behavior of the connection with ring joint gasket. In addition, it is important to know an optimum method for determining the bolt preloads taking account of the scatter in bolt preloads. In this paper, leakage tests for bolted flange connections with octagonal ring joint gaskets were conducted for cases where the bolt preloads are uniform and scattered. The sealing performance of these connections with ring joint gaskets was measured and evaluated. In addition, the leak rate was estimated using the contact gasket stress distributions of the connections when the bolt preloads were uniform and scattered using 3-D FEM. Finally, the measured leak rate for the connection using helium gas was compared with the estimated results. The estimated results are in fairly good agreement with the measured values. It is found that the sealing performance of the connections tightened with the uniform bolt methods is better than that with scattered bolt preloads.


Sign in / Sign up

Export Citation Format

Share Document