scholarly journals Development and Validation of Ultra Violet Spectrophotometric and Reversed-Phase High Performance Liquid Chromatography Techniques for Simultaneous Estimation of Brinzolamide and Brimonidine Tartrate in Ophthalmic Suspension Formulation

2015 ◽  
Vol 32 (2) ◽  
pp. 1111-1120 ◽  
Author(s):  
Gunasekar Manoharan ◽  
Mohammed Al Bratty
2019 ◽  
Vol 6 (2) ◽  
pp. 95
Author(s):  
Fikri Alatas ◽  
Hernandi Sujono ◽  
Woro Artati Sucipto

<p align="center"><strong>Abstrak</strong><strong></strong></p><p align="center"><strong> </strong></p><p>Metode kromatografi cair kinerja tinggi (KCKT) dengan detektor ultra lembayung telah dikembangkan dan divalidasi untuk estimasi kadar secara simultan campuran piridoksin hidroklorida (PH) dan piratiazin teoklat (PT)dalam sediaan tablet antiemetik. Proses pemisahan terjadi dalam kolom Inertsil® ODS-3 pada panjang gelombang 280 nm dengan laju alir 1,0 mL/menit. Fase gerak yang optimal untuk pemisahan adalah campuran methanol-asam asetat 1% (20:80) dengan waktu retensi PH dan PT berturut-turut adalah 1,2 dan 9,8 menit. Perolehan kembali PH dan PT berturut-turut adalah 100,13 dan 99,78 %. Batas deteksi untuk PH dan PT berturut-turut adalah 0,21 dan 0,22 µg/mL, sedangkan batas kuantisasinya berturut-turut adalah 0,70 dan  0,72 µg/mL. Metode ini dapat diterapkan sebagai metode untuk estimasi kadar campuran piridoksin hidroklorida dan piratiazin teoklat dalam bentuk sediaan tablet secara simultan.</p><p> </p><p><strong>Kata kunci:</strong> Piridoksin hidroklorida, piratiazin teoklat, KCKT, tablet</p><p> </p><p align="center"><strong><em>Development and validation of high performance liquid chromatography (HPLC) method for simultaneous estimation of antiemetic pyridoxyne hydrochloride and pyrathiazine theoclate in tablet dosage form</em></strong></p><p> </p><p align="center"><strong><em>Abstract</em></strong><strong><em></em></strong></p><p><em> </em></p><p><em>The high performance liquid chromatography (HPLC) method with an ultra violet detector has been developed and validated for simultaneous estimation of pyridoxine hydrochloride (PH) and pyrathiazine theoclate (PT) in antiemetic tablet preparations. The separation process occurs in the Inertsil® ODS-3 column at a wavelength of 280 nm with a flow rate of 1.0 mL /min. The optimal mobile phase for separation is a mixture of methanol-acetic acid 1% (20:80) with the retention times of PH and PT 1.2 and 9.8 minutes respectively. The recoveries of PH and PT were 100.13 and 99.78%, respectively. The detection limits for PH and PT were 0.21 and 0.22 µg / mL respectively, while the quantisation limits were 0.70 and 0.72 µg / mL, respectively. This method can be applied as a method for simultaneous estimating the levels of pyridoxine hydrochloride and pyrathiazine theoclate in tablet dosage form.</em><em></em></p><p><em> </em></p><p><strong><em>Keywords:</em></strong><em> Pyridoxine hydrochloride, pyrathiazine theoclate, HPLC, tablet</em></p>


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


Author(s):  
Bijithra Cholaraja ◽  
Shanmugasundaram P ◽  
Ragan G ◽  
Sankar Ask ◽  
Sumithra M

ABSTRACTObjective: To development and validation of a reversed-phase high-performance liquid chromatography (RP-HPLC) for the determination of modafinilin bulk and pharmaceutical dosage forms.Methods: A simple, precise, rapid, and accurate RP-HPLC method was developed for the estimation of modafinil in bulk and pharmaceutical dosageforms. Xterra RP 18 (250 mm × 4.6 mm, 5 µ particle size) with a mobile phase consisting of methanol:water 70:30 V/V was used. The flow rate1.0 ml/min and the effluents were monitored at 260 nm. The retention time and recovery time was 12 minutes. The detector response was linear inthe concentration of 10-50 µg/ml. The respective linear regression equation being Y=452.1x+65237. The limit of detection and limit of quantificationwere 4.547 and 1.377 mcg, respectively. The method was validated by determining its accuracy, precision, and system suitability.Result: The objective of the present work is to develop simple, precise, and reliable HPLC method for the analysis of modafinil in bulk andpharmaceutical dosage forms. This is achieved using the most commonly employed Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size) columndetection at 260 nm. The present method was validated according to ICH guidelines.Conclusion: In this study, a simple, fast and reliable HPLC method was developed and validated for the determination of modafinil in pharmaceuticalformulations.Keywords: Modafinil, Reversed-phase high-performance liquid chromatography, Estimation, ICH guidelines, Tablets. 


2020 ◽  
Vol 10 (4) ◽  
pp. 79-86
Author(s):  
Awdhut Pimpale ◽  
Rajendra Kakde

A Simple, precise, and accurate stability-indicating reversed-phase high-performance liquid chromatography method has been established for the simultaneous estimation of rosuvastatin calcium and fenofibrate in combined bulk and tablet formulation. The chromatographic separation was performed on reverse phase Princeton (C18) (250 mm x 4.6 mm, 5µ) column with mobile phase as a mixture of water (pH adjusted to 3.0 with orthophosphoric acid) and acetonitrile in the ratio (40:60) v/v at the flow rate 1.0 ml/min. Detection was carried out at wavelength 240 nm. The retention time under the optimized condition of Rosuvastatin calcium and Fenofibrate was found to be 2.485 & 3.905 minutes respectively. The calibration curve was linear in the range of 6-16 µg/ml and 87-232 µg/ml for rosuvastatin calcium and fenofibrate with a correlation coefficient of 0.9999 and 0.9994 respectively. Relative standard deviation values for all key parameters were less than 2.0%. The percentage recovery was found to be 99.66-100.37% and 99.13-100.44% for rosuvastatin calcium and fenofibrate respectively. The developed reversed-phase high-performance liquid chromatography method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical, and could be used for regular quality control of rosuvastatin calcium and fenofibrate in bulk and tablet formulations.  Keywords: Rosuvastatin calcium, Fenofibrate, RP-HPLC, Method validation, ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document