Introduction The free jejunal flap represents the gold standard for circumferential defects in upper digestive tract reconstruction. It is a technically demanding procedure with significant failure rates. Unrecognised failure leads to flap necrosis and potentially fatal sequelae, including sepsis and carotid artery bleed. Despite these catastrophic consequences, however, there remains no consensus on an optimum method for postoperative flap monitoring. Our unit has pioneered the use of external colour duplex ultrasound to monitor flap vascularity. We describe this technique and systematically review other published monitoring systems. Materials and methods A patient underwent oesophageal reconstruction using a jejunal free flap. Monitoring commenced immediately via external application of a colour duplex probe over the flap’s vascular pedicle to facilitate flow volume assessment. Further bi-daily assessments were successfully used to monitor the postoperative viability of the flap. The systematic review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Results Six alternative monitoring techniques were identified: exteriorised jejunal segment, implantable Doppler probe, watch window, microdialysis, microendoscopy and reflectance photoplethysmography. Discussion Exteriorised jejunal segment and implantable Doppler probe are most commonly described, yet both are associated with high false positive rates, which is particularly significant in a patient demographic facing increased general anaesthetic risk. Most other techniques remain experimental. External colour Doppler ultrasound provides the surgeon with immediate reassurance following the reconstruction, requires minimal training to use, and eliminates the need for revisional procedures. Conclusion Our initial experience suggests that external colour Doppler ultrasound has exciting potential as an efficient and noninvasive technique for monitoring the free jejunal flap.

1996 ◽  
Vol 75 (02) ◽  
pp. 242-245 ◽  
Author(s):  
Marie Magnusson ◽  
Bengt I Eriksson ◽  
Peter Kãlebo ◽  
Ramon Sivertsson

SummaryPatients undergoing orthopedic surgery are at high risk of developing deep vein thrombosis. One hundred and thirty-eight consecutive patients undergoing total hip replacement or hip fracture surgery were included in this study. They were surveilled with colour Doppler ultrasound (CDU) and bilateral ascending contrast phlebography. The prevalence of proximal and distal DVT in this study was 5.8% and 20.3% respectively.CDU has a satisfactory sensitivity in patients with symptomatic deep vein thrombosis, especially in the proximal region. These results could not be confirmed in the present study of asymptomatic patients. The sensitivity was 62.5% (95% confidence interval: C.I. 24-91%) and the specificity 99.6% (C.I. 98-100%) for proximal DVT; 53.6% (C.I. 34-73%) and 98% (C.I. 96-99%) respectively for distal thrombi. The overall sensitivity was 58.1% (C.I. 39-75%) and the specificity 98% (C.I. 96-99%). The positive predictive value was 83.3% (C.I. 36-99%) and 75% (C.I. 51-91%) for proximal and distal DVT respectively. The negative predictive value was 98.9% (C.I. 98-100%) and 94.9% (C.I. 92-98%) for proximal and distal DVT respectively. The results of this study showed that even with a highly specialised and experienced investigator the sensitivity of CDU was too low to make it suitable for screening purposes in a high risk surgical population.


1995 ◽  
Vol 50 (9) ◽  
pp. 618-622 ◽  
Author(s):  
G.M. Baxter ◽  
H. Ireland ◽  
J.G. Moss ◽  
P.N. Harden ◽  
B.J.R. Junor ◽  
...  

2004 ◽  
Vol 34 (8) ◽  
pp. 614-619 ◽  
Author(s):  
Jos A. M. Bramer ◽  
Feikje M. Gubler ◽  
Mario Maas ◽  
Hans Bras ◽  
Jan de Kraker ◽  
...  

1996 ◽  
Vol 69 (825) ◽  
pp. 810-815 ◽  
Author(s):  
G M Baxter ◽  
F Aitchison ◽  
D Sheppard ◽  
J G Moss ◽  
M J McLeod ◽  
...  

1996 ◽  
Vol 11 (10) ◽  
pp. 2333-2333
Author(s):  
A. Tekay ◽  
H. Martikainen ◽  
P Jouppila

2013 ◽  
Vol 3 (4) ◽  
pp. 304 ◽  
Author(s):  
Rei K. Chiou ◽  
Himanshu Aggarwal ◽  
Christopher R. Chiou ◽  
Fleur Broughton ◽  
Susan Liu

Background: Information in the literature on the hemodynamic characteristicsof priapism, especially after therapeutic intervention, isvery limited. We analyzed our colour Doppler ultrasound (CDU)studies performed for patients with various durations of priapismbefore and after therapeutic intervention.Methods: We reviewed 52 CDU studies for 24 patients with priapismbefore and after treatment for the period 1997–2007. Theduration of priapism ranged from 4 hours to 8 days. We performed17 CDU studies in 8 patients who presented with a duration ofpriapism of 7 hours or less, 9 studies in 4 patients who presentedwith duration of priapism of more than 20 hours, 23 studies in11 patients referred to us after they had failed prior therapeuticintervention at other institutions and 3 studies in 1 patient withpriapism related to perineal trauma.Results: Among the 8 patients who presented with a duration ofpriapism of 7 hours or less, CDU studies on presentation showeddetectible cavernosal arterial flow in all except 1 study. Amongthe 4 patients who presented with a duration of more than 20 hours,the studies showed no detectible cavernosal arterial blood flow.We repeated CDU studies after therapeutic intervention, and theyshowed restoration of cavernosal arterial flow with relief of venoocclusivestatus. Among the 11 patients in whom prior treatmentsfailed before they were referred to us, CDU studies performed onpresentation showed no detectible cavernosal arterial flow in 10of the 11 patients. We performed 12 CDU studies in 8 patientsafter placing a penile cavernosa-dorsal vein (CD) shunt. Weobserved the presence of blood flow in the CD shunt, indicatingits patency in all 8 patients. Some patients showed high cavernosalarterial flow (peak systolic velocity [PSV] up to 27.6 cm/s) aftersurgery. These patients appeared to have residual priapism of primarilyarteriogenic status that improved after observation.Conclusion: After therapeutic intervention, CDU study is useful toassess the relief of arteriogenic and veno-occlusive status and thedecision for further treatment.Contexte : La littérature offre très peu de renseignements sur lescaractéristiques hémodynamiques du priapisme, en particulieraprès une intervention thérapeutique. Nous avons analysé les donnéesprovenant d’examens par échographie Doppler en couleurs(ÉDC) menés avant et après une intervention thérapeutique chezdes patients atteints de priapisme de durée variable.Méthodes : Nous avons passé en revue les données de 52 examenspar échographie Doppler en couleurs effectués avant et après letraitement de 24 patients atteints de priapisme entre 1997 et 2007.La durée du priapisme variait entre 4 heures et 8 jours. Dix-septÉDC ont été effectuées chez 8 patients ayant présenté un priapismed’une durée maximale de 7 heures; 9 ÉDC ont été effectuées chez4 patients ayant présenté un priapisme d’une durée de plus de20 heures. Finalement, 23 ÉDC ont été effectuées chez 11 patientsqui nous avaient été dirigés en raison de l’échec de l’interventionthérapeutique antérieure dans d’autres établissements. Trois ÉDCont été menées chez un patient atteint d’un priapisme relié à untraumatisme périnéal.Résultats : Chez les 8 patients dont le priapisme avait eu une duréemaximale de 7 heures, les ÉDC ont montré au départ un débit sanguinperceptible dans l’artère caverneuse dans tous les cas sauf un. Surles 4 patients dont le priapisme avait duré plus de 20 heures, les examenspar ÉDC n’ont montré aucun débit sanguin dans l’artère caverneuseau départ. Les ÉDC ont été répétées après l’interventionthérapeutique et ont permis d’observer un retour du débit sanguindans l’artère caverneuse avec soulagement de l’occlusion veineuse.Chez les 11 patients qui n’avaient pas répondu aux traitementsantérieurs avant de nous consulter, les ÉDC effectuées au départ n’ontmontré aucun débit sanguin perceptible dans l’artère caverneusedans 10 cas. Nous avons effectué 12 ÉDC chez 8 patients après unedérivation veineuse dorso-caverneuse et avons observé la présenced’un débit sanguin dans la dérivation, montrant sa perméabilité chezles 8 patients. Chez certains patients, on a noté un débit sanguinélevé dans l’artère caverneuse (vitesse systolique maximale de27,6 cm/sec) après la chirurgie. Ces patients semblaient présenter unpriapisme résiduel artériogène primaire qui s’est résorbé par la suite.Conclusion : Après une intervention thérapeutique, les examens parÉDC permettent d’évaluer le soulagement des troubles artériogèneset/ou veino-occlusifs et d’orienter le traitement subséquent.


Sign in / Sign up

Export Citation Format

Share Document