scholarly journals Size effect on shear failure at core region of reinforced concrete connections: Experimental study

2018 ◽  
Vol 49 (4) ◽  
pp. 455-468
Author(s):  
Liu JIN ◽  
LiYue MIAO ◽  
Na WEI ◽  
XiuLi DU ◽  
ZhenBao LI
2021 ◽  
Vol 245 ◽  
pp. 112951
Author(s):  
Liu Jin ◽  
Yushuang Lei ◽  
Wenxuan Yu ◽  
Xiuli Du

2017 ◽  
Vol 902 ◽  
pp. 33-40
Author(s):  
Cong Thuat Dang ◽  
Ngoc Hieu Dinh

Old reinforced concrete buildings constructed around 1980’s in many developing countries have been designed against mainly gravity load. Beam-column joints in these buildings contain slightly or no shear reinforcement inside the panel zones due to the construction convenience, and are vulnerable to shear failure in beam-column joints under the action of earthquake loads, especially for the exterior beam-column joints. This experimental study aimed to investigate the seismic performance of five half-scale exterior beam-column joints simulating the joints in existing reinforced-concrete buildings with non-shear hoop details. The test results showed that the structural performances of the beam-column joints under earthquake including failure mode, load-drift ratio relationship, shear strain of the joints and energy dissipation are strongly affected by the amount of longitudinal reinforcing bars of beams.


2018 ◽  
Vol 2018 ◽  
pp. 1-19
Author(s):  
Chunyi Yu ◽  
Hua Ma ◽  
Yongping Xie ◽  
Zhenbao Li ◽  
Zhenyun Tang

The size effect on the seismic performance of conventional reinforced concrete columns has been observed in terms of flexural failure and shear failure. Under earthquake loading, slender columns experience flexural failure, and short columns experience flexure-shear failure and shear failure. However, the effect of section size on the seismic performance of high-strength reinforced concrete columns under the conditions of different shear span-to-depth ratios requires further confirmation. For this purpose, six high-strength reinforced concrete columns with shear span-to-depth ratios of 2 and 4 were subjected to cyclic loading in this study. The experimental results indicated that relative nominal flexural strength, energy dissipation coefficient, factor of safety, and local factor of safety all exhibited a strong size effect by decreasing with increasing column size. Furthermore, the size effect became stronger as the shear span-to-depth ratio was increased, except for average energy dissipation coefficient. The observed changes in the factor of safety were in good agreement with the Type 2 size effect model proposed by Bažant. Thus, based on the local factor of safety and Bažant’s Type 2 model, the code equation for moment capacity of different shear span-to-depth ratios was modified to provide a consistent factor of safety regardless of column size.


2017 ◽  
Vol 34 (2) ◽  
pp. 188-198
Author(s):  
Ho-Kyung Lee ◽  
Hyo-Myeong Gong ◽  
Seung-Min Baek ◽  
Woo-Suk Kim ◽  
Yoon-Keun Kwak

Sign in / Sign up

Export Citation Format

Share Document