Simultaneous imaging of multiple focal planes using a two-photon scanning microscope

2007 ◽  
Vol 32 (12) ◽  
pp. 1731 ◽  
Author(s):  
W. Amir ◽  
R. Carriles ◽  
E. E. Hoover ◽  
T. A. Planchon ◽  
C. G. Durfee ◽  
...  
2017 ◽  
Vol 5 (2) ◽  
pp. 470-475 ◽  
Author(s):  
Shu Chen ◽  
Yong-Chao Zheng ◽  
Mei-Ling Zheng ◽  
Xian-Zi Dong ◽  
Feng Jin ◽  
...  

Nondegenerate two-photon absorption of a newly carbazole derivative is reported, demonstrating its potential use in a two-color two-photon laser scanning microscope.


2019 ◽  
Author(s):  
Peter Ledochowitsch ◽  
Lawrence Huang ◽  
Ulf Knoblich ◽  
Michael Oliver ◽  
Jerome Lecoq ◽  
...  

AbstractMultiphoton calcium imaging is commonly used to monitor the spiking of large populations of neurons. Recovering action potentials from fluorescence necessitates calibration experiments, often with simultaneous imaging and cell-attached recording. Here we performed calibration for imaging conditions matching those of the Allen Brain Observatory. We developed a novel crowd-sourced, algorithmic approach to quality control. Our final data set was 50 recordings from 35 neurons in 3 mouse lines. Our calibration indicated that 3 or more spikes were required to produce consistent changes in fluorescence. Moreover, neither a simple linear model nor a more complex biophysical model accurately predicted fluorescence for small numbers of spikes (1-3). We observed increases in fluorescence corresponding to prolonged depolarizations, particularly in Emx1-IRES-Cre mouse line crosses. Our results indicate that deriving spike times from fluorescence measurements may be an intractable problem in some mouse lines.


2017 ◽  
pp. 531-537 ◽  
Author(s):  
F. NADRIGNY ◽  
K. LE MEUR ◽  
E. D. SCHOMBURG ◽  
S. SAFAVI-ABBASI ◽  
P. DIBAJ

We developed appropriate surgical procedures for single and repetitive multi-photon imaging of spinal cord in vivo. By intravenous anesthesia, artificial ventilation and laminectomy, acute experiments were performed in the dorsal and lateral white matter. By volatile anesthesia and minimal-invasive surgery, chronic repetitive imaging up to 8 months was performed in the dorsal column through the window between two adjacent spines. Transgenic mouse technology enabled simultaneous imaging of labeled axons, astrocytes and microglia. Repetitive imaging showed positional shifts of microglia over time. These techniques serve for investigations of cellular dynamics and cell-cell interactions in intact and pathologically changed spinal tissue.


2002 ◽  
Author(s):  
Vijay Iyer ◽  
Tycho Hoogland ◽  
Bradley E. Losavio ◽  
A. R. McQuiston ◽  
Peter Saggau

2000 ◽  
Vol 278 (6) ◽  
pp. H2150-H2156 ◽  
Author(s):  
W. Gil Wier ◽  
C. William Balke ◽  
Jeffrey A. Michael ◽  
Joseph R. H. Mauban

We describe a custom one-photon (confocal) and two-photon all-digital (photon counting) laser scanning microscope. The confocal component uses two avalanche photodiodes (APDs) as the fluorescence detector to achieve high sensitivity and to overcome the limited photon counting rate of a single APD (∼5 MHz). The confocal component is approximately nine times more efficient than our commercial confocal microscope (fluorophore fluo 4). Switching from one-photon to two-photon excitation mode (Ti:sapphire laser) is accomplished by moving a single mirror beneath the objective lens. The pulse from the Ti:sapphire laser is 109 fs in duration at the specimen plane, and average power is ∼5 mW. Two-photon excited fluorescence is detected by a fast photomultiplier tube. With a ×63 1.4 NA oil-immersion objective, the resolution of the confocal system is 0.25 μm laterally and 0.52 μm axially. For the two-photon system, the corresponding values are 0.28 and 0.82 μm. The system is advantageous when excitation intensity must be limited, when fluorescence is low, or when thick, scattering specimens are being studied (with two-photon excitation).


2016 ◽  
Vol 23 (4) ◽  
pp. 959-965 ◽  
Author(s):  
Justin A. Newman ◽  
Shijie Zhang ◽  
Shane Z. Sullivan ◽  
Ximeng Y. Dow ◽  
Michael Becker ◽  
...  

Synchronous digitization, in which an optical sensor is probed synchronously with the firing of an ultrafast laser, was integrated into an optical imaging station for macromolecular crystal positioning prior to synchrotron X-ray diffraction. Using the synchronous digitization instrument, second-harmonic generation, two-photon-excited fluorescence and bright field by laser transmittance were all acquired simultaneously with perfect image registry at up to video-rate (15 frames s−1). A simple change in the incident wavelength enabled simultaneous imaging by two-photon-excited ultraviolet fluorescence, one-photon-excited visible fluorescence and laser transmittance. Development of an analytical model for the signal-to-noise enhancement afforded by synchronous digitization suggests a 15.6-fold improvement over previous photon-counting techniques. This improvement in turn allowed acquisition on nearly an order of magnitude more pixels than the preceding generation of instrumentation and reductions of well over an order of magnitude in image acquisition times. These improvements have allowed detection of protein crystals on the order of 1 µm in thickness under cryogenic conditions in the beamline. These capabilities are well suited to support serial crystallography of crystals approaching 1 µm or less in dimension.


2009 ◽  
Vol 102 (2) ◽  
pp. 1310-1314 ◽  
Author(s):  
Thomas H. Chia ◽  
Michael J. Levene

Cortical slices allow for simultaneous imaging of multiple cortical layers. However, slices lack native physiological inputs and outputs. Although in vivo, two-photon imaging preserves the native context, it is typically limited to a depth of <500 μm. In addition, simultaneous imaging of multiple cortical layers is difficult due to the stratified organization of the cortex. We demonstrate the use of 1-mm microprisms for in vivo, two-photon neocortical imaging. These prisms enable simultaneous imaging of multiple cortical layers, including layer V, at an angle typical of slice preparations. Images were collected from the mouse motor and somatosensory cortex and show a nearly 900-μm-wide field of view. At high-magnification imaging using an objective with 1-mm of coverglass correction, resolution is sufficient to resolve dendritic spines on layer V neurons. Images collected using the microprism are comparable to images collected from a traditional slice preparation. Functional imaging of blood flow at various neocortical depths is also presented, allowing for quantification of red blood cell flux and velocity. H&E staining shows the surrounding tissue remains in its native, stratified organization. Estimation of neuronal damage using propidium iodide and a fluorescent Nissl stain reveals cell damage is limited to <100 μm from the tissue–glass interface. Microprisms are a straightforward tool offering numerous advantages for INTO NEOCORTICAL STISSUE.