scholarly journals Aluminium, gold-tin and titanium-tungsten alloys for mid-infrared plasmonic gratings

2021 ◽  
Vol 11 (4) ◽  
pp. 1058 ◽  
Author(s):  
Jasmin Spettel ◽  
Gerald Stocker ◽  
Thang Duy Dao ◽  
Reyhaneh Jannesari ◽  
Andreas Tortschanoff ◽  
...  
2021 ◽  
Vol 2015 (1) ◽  
pp. 012149
Author(s):  
J Spettel ◽  
G Stocker ◽  
T D Dao ◽  
R Jannesari ◽  
A Tortschanoff ◽  
...  

Abstract We numerically and experimentally investigate aluminum metal (Al), gold-tin (AuSn) and titanium-tungsten (TiW) metallic alloys as plasmonic materials in the mid-infrared (MIR) region using spectroscopic ellipsometry and reflection measurements of gratings. The angle dependence of the specular reflectance of shallow gratings is investigated using a free-beam measurement setup and compared to simulations. It is shown that the deep and narrow resonances observed for all three materials match the associated prediction from simulations.


2016 ◽  
Vol 24 (14) ◽  
pp. 16175 ◽  
Author(s):  
Franziska B. Barho ◽  
Fernando Gonzalez-Posada ◽  
Maria-José Milla-Rodrigo ◽  
Mario Bomers ◽  
Laurent Cerutti ◽  
...  

2005 ◽  
Vol 14 ◽  
pp. 337-342 ◽  
Author(s):  
M. Dolci ◽  
G. Valentini ◽  
O. Straniero ◽  
G. Di Rico ◽  
M. Ragni ◽  
...  

2018 ◽  
Author(s):  
Y. H. Kan ◽  
Changying Zhao ◽  
Zhuomin M. Zhang

2011 ◽  
Vol 28 (1) ◽  
pp. 33-48 ◽  
Author(s):  
Oto Hanuš ◽  
Václava Genčurová ◽  
Yunhai Zhang ◽  
Pavel Hering ◽  
Jaroslav Kopecký ◽  
...  

Milk acetone determination by the photometrical method after microdiffusion and via FT infra-red spectroscopyMilk acetone (AC) and betahydroxybutyrate (BHB) are important indicators of the energy metabolism of cows (ketosis occurrence) and an effective method for their determination, with reliable results, is of great importance. The goal of this work was to investigate the infrared method MIR-FT in terms of its calibration for milk AC and to develop a usable procedure. The microdiffusion photometric (485 nm; Spekol 11) method was used with salicylaldehyde as a reference (Re) and mid infrared spectroscopy FT (MIR-FT: Lactoscope FT-IR, Delta; MilkoScan FT 6000, M-Sc) as an indirect method. The acetone addition to milk had no recovery using MIR-FT (Delta). The reference AC set must have acceptable statistics for good MIR-FT calibration (M-Sc) and they were: 10.1 ± 9.74 at a geometric mean of 7.26 mg l-1, and a variation range from 1.98 to 33.66 mg l-1. The AC correlation between Re and MIR-FT (Delta) was low at 0.32 (P>0.05 but the Log AC relationship between Re and MIR-FT (M-Sc) was markedly better at 0.80 (P<0.01). The conversion of >10 mg l-1 as an AC subclinical ketosis limit could be > -0.80 (feedback 0.158 mmol l-1 = 9.25 mg l-1) and > -1.66. This could be important for ketosis monitoring (using M-Sc).


2020 ◽  
Vol 13 (4) ◽  
pp. 722-727
Author(s):  
ZHU Ye-xin ◽  
◽  
◽  
LI Ya-nan ◽  
SHI Wei-jie ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document