scholarly journals Reconstruction of membrane current by deconvolution and its application to membrane capacitance measurements in cardiac myocytes

PLoS ONE ◽  
2017 ◽  
Vol 12 (11) ◽  
pp. e0188452 ◽  
Author(s):  
Matej Hoťka ◽  
Ivan Zahradník
2006 ◽  
Vol 96 (5) ◽  
pp. 2539-2548 ◽  
Author(s):  
Zhen-Yu Zhou ◽  
Qun-Fang Wan ◽  
Pratima Thakur ◽  
Ruth Heidelberger

The mouse is an important model system for understanding the molecular basis of neuronal signaling and diseases of synaptic communication. However, the best-characterized retinal ribbon-style synapses are those of nonmammalian vertebrates. To remedy this situation, we asked whether it would be feasible to track synaptic vesicle dynamics in the isolated mouse rod bipolar cell using time-resolved capacitance measurements. The results demonstrate that membrane depolarization triggered an increase in membrane capacitance that was Ca2+ dependent and restricted to the synaptic compartment, consistent with exocytosis. The amplitude of the capacitance response recorded from the easily accessible soma of an intact mouse rod bipolar cell was identical to that recorded directly from the small synaptic terminal, suggesting that in the carefully selected cohort of cells presented here, axonal resistance was not a significant barrier to current flow. This supposition was supported by the analysis of passive membrane properties and a comparison of membrane capacitance measurements in cells with and without synaptic terminals and reinforced by the lack of an effect of sine-wave frequency (200–1,600 Hz) on the measured capacitance increase. The magnitude of the capacitance response increased with Ca2+ entry until a plateau was reached at a spatially averaged intraterminal calcium of about 600 nM. We interpret this plateau, nominally 30 fF, as corresponding to a releasable pool of synaptic vesicles. The robustness of this measure suggests that capacitance measurements may be used in the mouse rod bipolar cell to compare pool size across treatment conditions.


1998 ◽  
Vol 275 (4) ◽  
pp. H1216-H1224 ◽  
Author(s):  
Seth J. Rials ◽  
Xiaoping Xu ◽  
Ying Wu ◽  
Roger A. Marinchak ◽  
Peter R. Kowey

Recent studies indicate that regression of left ventricular hypertrophy (LVH) normalizes the in situ electrophysiological abnormalities of the left ventricle. This study was designed to determine whether regression of LVH also normalizes the abnormalities of individual membrane currents. LVH was induced in rabbits by renal artery banding. Single ventricular myocytes from rabbits with LVH at 3 mo after renal artery banding demonstrated increased cell membrane capacitance, prolonged action potential duration, decreased inward rectifier K+ current density, and increased transient outward K+ current density compared with myocytes from age-matched controls. Additional rabbits were randomized at 3 mo after banding to treatment with either vehicle or captopril for an additional 3 mo. Myocytes from LVH rabbits treated with vehicle showed persistent membrane current abnormalities. However, myocytes isolated from LVH rabbits treated with captopril had normal cell membrane capacitance, action potential duration, and membrane current densities. Captopril had no direct effect on membrane currents of either control or LVH myocytes. These data support the hypothesis that the action potential prolongation and membrane current abnormalities of LVH are reversed by regression. Normalization of membrane currents probably explains the reduced vulnerability to ventricular arrhythmia observed in this LVH model after treatment with captopril.


2009 ◽  
Vol 102 (4) ◽  
pp. 2161-2175 ◽  
Author(s):  
Jorge Golowasch ◽  
Gladis Thomas ◽  
Adam L. Taylor ◽  
Arif Patel ◽  
Arlene Pineda ◽  
...  

During growth or degeneration neuronal surface area can change dramatically. Measurements of membrane protein concentration, as in ion channel or ionic conductance density, are often normalized by membrane capacitance, which is proportional to the surface area, to express changes independently from cell surface variations. Several electrophysiological protocols are used to measure cell capacitance, all based on the assumption of membrane isopotentiality. Yet, most neurons violate this assumption because of their complex anatomical structure, raising the question of which protocol yields measurements that are closest to the actual total membrane capacitance. We measured the capacitance of identified neurons from crab stomatogastric ganglia using three different protocols: the current-clamp step, the voltage-clamp step, and the voltage-clamp ramp protocols. We observed that the current-clamp protocol produced significantly higher capacitance values than those of either voltage-clamp protocol. Computational models of various anatomical complexities suggest that the current-clamp protocol can yield accurate capacitance estimates. In contrast, the voltage-clamp protocol estimates rapidly deteriorate as isopotentiality is reduced. We provide a mathematical description of these results by analyzing a simple two-compartment model neuron to facilitate an intuitive understanding of these methods. Together, the experiments, modeling, and mathematical analysis indicate that accurate total membrane capacitance measurements cannot be obtained with voltage-clamp protocols in nonisopotential neurons. Furthermore, although current-clamp steps can theoretically yield accurate measurements, experimentalists should be aware of limitations imposed by step duration and numerical errors during fitting procedures to obtain the membrane time constant.


2000 ◽  
Vol 82 ◽  
pp. 184
Author(s):  
Yasunori Momose ◽  
Tatsuhiko Iwase ◽  
Sachiko Yokota ◽  
Naomi Kobayashi ◽  
Fu-Shih Chen

Sign in / Sign up

Export Citation Format

Share Document