membrane capacitance
Recently Published Documents


TOTAL DOCUMENTS

239
(FIVE YEARS 35)

H-INDEX

39
(FIVE YEARS 4)

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 463
Author(s):  
Shide Bakhtiari ◽  
Mohammad K. D. Manshadi ◽  
Amin Mansoorifar ◽  
Ali Beskok

Dielectric spectroscopy (DS) is a promising cell screening method that can be used for diagnostic and drug discovery purposes. The primary challenge of using DS in physiological buffers is the electrode polarization (EP) that overwhelms the impedance signal within a large frequency range. These effects further amplify with the miniaturization of the measurement electrodes. In this study, we present a microfluidic system and the associated equivalent circuit models for real-time measurements of cell membrane capacitance and cytoplasm resistance in physiological buffers with 10 s increments. The current device captures several hundreds of biological cells in individual microwells through gravitational settling and measures the system’s impedance using microelectrodes covered with dendritic gold nanostructures. Using PC-3 cells (a highly metastatic prostate cancer cell line) suspended in cell growth media (CGM), we demonstrate stable measurements of cell membrane capacitance and cytoplasm resistance in the device for over 15 min. We also describe a consistent application of the equivalent circuit model, starting from the reference measurements used to determine the system parameters. The circuit model is tested using devices with varying dimensions, and the obtained cell parameters between different devices are nearly identical. Further analyses of the impedance data have shown that accurate cell membrane capacitance and cytoplasm resistance can be extracted using a limited number of measurements in the 5 MHz to 10 MHz range. This will potentially reduce the timescale required for real-time DS measurements below 1 s. Overall, the new microfluidic device can be used for the dielectric characterization of biological cells in physiological buffers for various cell screening applications.


2022 ◽  
Author(s):  
Joseph Santos-Sacchi

Outer hair cell (OHC) nonlinear membrane capacitance (NLC) represents voltage-dependent sensor charge movements within prestin (SLC26a5) that drive OHC electromotility. Dielectric loss, a shift in charge movement phase from purely capacitive to resistive, is likely indicative of prestin interaction with the viscous lipid bilayer and has been suggested to correspond to prestin power output. The frequency response of NLC in OHC membrane patches has been measured with phase tracking and complex capacitance methodologies. While the latter approach can directly determine the presence of dielectric loss by assessing charge movement both in and out of phase with driving voltage, the former has been suggested to fail in this regard. Here we show that standard phase tracking in the presence of dielectric loss does indeed register this loss. Such estimates of NLC correspond to the absolute magnitude of complex NLC, indicating that total charge movement regardless of phase is assessed, thereby validating past and present measures of NLC frequency response that limits its effectiveness at high frequencies. This observation has important implications for understanding the role of prestin in cochlear amplification.


Author(s):  
Shide Bakhtiari ◽  
Mohammad K. D. Manshadi ◽  
Amin Mansoorifar ◽  
Ali Beskok

Dielectric spectroscopy (DS) is a promising cell screening method that can be used for diagnostic and drug discovery purposes. The primary challenge of using DS in physiological buffers is the electrode polarization (EP) that overwhelms the impedance signal within a large frequency range. These effects further amplify with miniaturization of the measurement electrodes. In this study, we present a microfluidic system and the associated equivalent circuit models for real-time measurements of cell membrane capacitance and cytoplasm resistance in physiological buffers with 10s increments. The current device captures several hundreds of biological cells in individual microwells through gravitational settling and measures the system’s impedance using microelectrodes covered with dendritic gold nanostructures. Using PC-3 cells (a highly metastatic prostate cancer cell line) suspended in cell growth media (CGM), we demonstrate stable measurements of cell membrane capacitance and cytoplasm resistance in the device for over 15 minutes. We also describe a consistent application of the equivalent circuit model, starting from the reference measurements used to determine the system parameters. The circuit model is tested using devices with varying dimensions, and the obtained cell parameters between different devices are nearly identical. Further analyses of the impedance data have shown that accurate cell membrane capacitance and cytoplasm resistance can be extracted using a limited number of measurements in the 5 MHz to 10 MHz range. This will potentially reduce the timescale required for real-time DS measurements below 1s. Overall the new microfluidic device can be used for dielectric characterization of biological cells in physiological buffers for various cell screening applications.


Author(s):  
Bernard Delalande ◽  
Hirohisa Tamagawa ◽  
Vladimir Matveev

The most common and taught membrane theory assumes that the membrane behaves as a kind of electrical capacitance that is exposed to an electrical current generated by an ionic flow. If this statement is verifiable, it can be confirmed by the laws of physics, mathematics and in particular electricity. We will demonstrate that this hypothesis is not verified and that it is necessary to modify biophysics according to already established and experimentally verified principles of physics.


2021 ◽  
Vol 153 (4) ◽  
Author(s):  
Shannon H. Romer ◽  
Sabrina Metzger ◽  
Kristiana Peraza ◽  
Matthew C. Wright ◽  
D. Scott Jobe ◽  
...  

Huntington’s disease (HD) is a fatal and progressive condition with severe debilitating motor defects and muscle weakness. Although classically recognized as a neurodegenerative disorder, there is increasing evidence of cell autonomous toxicity in skeletal muscle. We recently demonstrated that skeletal muscle fibers from the R6/2 model mouse of HD have a decrease in specific membrane capacitance, suggesting a loss of transverse tubule (t-tubule) membrane in R6/2 muscle. A previous report also indicated that Cav1.1 current was reduced in R6/2 skeletal muscle, suggesting defects in excitation–contraction (EC) coupling. Thus, we hypothesized that a loss and/or disruption of the skeletal muscle t-tubule system contributes to changes in EC coupling in R6/2 skeletal muscle. We used live-cell imaging with multiphoton confocal microscopy and transmission electron microscopy to assess the t-tubule architecture in late-stage R6/2 muscle and found no significant differences in the t-tubule system density, regularity, or integrity. However, electron microscopy images revealed that the cross-sectional area of t-tubules at the triad were 25% smaller in R6/2 compared with age-matched control skeletal muscle. Computer simulation revealed that the resulting decrease in the R6/2 t-tubule luminal conductance contributed to, but did not fully explain, the reduced R6/2 membrane capacitance. Analyses of bridging integrator-1 (Bin1), which plays a primary role in t-tubule formation, revealed decreased Bin1 protein levels and aberrant splicing of Bin1 mRNA in R6/2 muscle. Additionally, the distance between the t-tubule and sarcoplasmic reticulum was wider in R6/2 compared with control muscle, which was associated with a decrease in junctophilin 1 and 2 mRNA levels. Altogether, these findings can help explain dysregulated EC coupling and motor impairment in Huntington’s disease.


Author(s):  
Darryl Dieujuste ◽  
Yuhao Qiang ◽  
Sarah Du

This paper presents the development and testing of a low-cost (< $60), portable, electrical impedance based microflow cytometer for single cell analysis under controlled oxygen microenvironment. The system is based on an AD5933 impedance analyzer chip, a microfluidic chip, and an Arduino microcontroller operated by a custom Android application. A representative case study on human red blood cells (RBCs) affected by sickle cell disease is conducted to demonstrate the capability of the cytometry system. An equivalent circuit model of a suspended biological cell is used to interpret the electrical impedance of single flowing RBCs. RBCs exhibit decreased mean membrane capacitance by 24% upon hypoxia treatment while the mean cytoplasmic resistance remains consistent. RBCs affected by sickle cell disease exhibit decreased cytoplasmic resistance and increased membrane capacitance upon hypoxia treatment. Strong correlations are identified between the changes in the cells’ subcellular electrical components and the hypoxia-induced cell sickling process. The results reported in this paper suggest that the developed method of testing demonstrates the potential application for low-cost screening technique for sickle cell disease and other diseases in the field and low-resource settings. The developed system and methodology can be extended to analyze cellular response to hypoxia in other cell types.


2021 ◽  
Vol 120 (3) ◽  
pp. 240a
Author(s):  
Bernardo Pinto ◽  
Carlos Alberto Z. Bassetto Jr ◽  
Ramon Latorre ◽  
Francisco Bezanilla

Sign in / Sign up

Export Citation Format

Share Document