scholarly journals The Use of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) for the Identification of Pathogens Causing Sepsis

2019 ◽  
Vol 3 (4) ◽  
pp. 675-685 ◽  
Author(s):  
Paul M Luethy ◽  
J Kristie Johnson

Abstract Background Sepsis is a life-threatening condition with high rates of morbidity and mortality; effective and appropriate antibiotic therapy is essential for ensuring patient improvement. To aid in the diagnosis of sepsis, blood cultures are drawn and sent to the microbiology laboratory for pathogen growth, identification, and susceptibility testing. The clinical microbiology laboratory can assist the medical team by providing timely identification of the pathogen(s) causing the bloodstream infection through the use of rapid diagnostic technology. One of these rapid diagnostic technologies, MALDI-TOF MS, has been proven to reduce the time required for appropriate antibiotic therapy when used to identify pathogens grown in culture. This technology has also been used to identify pathogens directly from the positive blood cultures with great success. Content In this minireview, we summarize the different methods that have been developed to directly identify pathogens from positive blood cultures by use of MALDI-TOF MS and the effect of this technology on patient outcomes. Additionally, we touch on current research in the field, including the identification of antimicrobial resistance directly from positive blood cultures by MALDI-TOF MS. Summary Rapid identification of pathogens is important in the survival of patients undergoing a septic event. MALDI-TOF MS technology has played an important role in rapid identification, which has led to a reduction in the time to appropriate antibiotic therapy and contributed to the improvement of patient outcomes. The high sensitivity and specificity of MALDI-TOF MS identification, in combination with MALDI-TOF's rapid function and reduced labor costs, make this technology an attractive choice for clinical laboratories.

Anaerobe ◽  
2018 ◽  
Vol 54 ◽  
pp. 151-158 ◽  
Author(s):  
Peivern Fong ◽  
Michelle J. Francis ◽  
John F. Hamblin ◽  
Tony M. Korman ◽  
Maryza Graham

Author(s):  
Hazan Zengin Canalp ◽  
Banu Bayraktar

Using MALDI-TOF MS directly from blood culture bottles reduces the time required for pathogen identification, and the turnaround times for final identification have been compared with overnight incubation from solid media in previous studies. However, identification from a short incubation of agar plates has been increasingly accepted and successfully implemented in routine laboratories, but there is no data comparing direct MALDI-TOF MS with the short-term, incubated agar plates.


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Cesira Giordano ◽  
Elena Piccoli ◽  
Veronica Brucculeri ◽  
Simona Barnini

Rapid identification of bloodstream pathogens by MALDI-TOF MS and the recently introduced rapid antimicrobial susceptibility testing (rAST) directly from positive blood cultures allow clinicians to promptly achieve a targeted therapy, especially for multidrug resistant microorganisms. In the present study, we propose a comparison between phenotypical rASTs performed in light-scattering technology (Alfred 60AST, Alifax®) and fluorescencein situhybridization (Pheno™, Accelerate) directly from positive blood cultures, providing results in 4–7 hours. Blood samples from 67 patients admitted to the Azienda Ospedaliero-Universitaria Pisana were analyzed. After the direct MALDI-TOF MS identification, the rAST was performed at the same time both on Alfred 60AST and Pheno. Alfred 60AST provided qualitative results, interpreted in terms of clinical categories (SIR). Pheno provided identification and MIC values for each antibiotic tested. Results were compared to the broth microdilution assay (SensiTitre™, Thermo Fisher Scientific), according to EUCAST rules. Using Alfred 60AST, an agreement was reached, 91.1% for Gram-negative and 95.7% for Gram-positive bacteria, while using Pheno, the agreement was 90.6% for Gram-negative and 100% for Gram-positive bacteria. Both methods provided reliable results; Alfred 60AST combined with MALDI-TOF MS proved itself faster and cheaper. Pheno provided identification and MIC determination in a single test and, although more expensive, may be useful whenever MIC value is necessary and where MALDI-TOF MS is not present.


2013 ◽  
Vol 303 (4) ◽  
pp. 205-209 ◽  
Author(s):  
Christian Leli ◽  
Elio Cenci ◽  
Angela Cardaccia ◽  
Amedeo Moretti ◽  
Francesco D’Alò ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document