Comparative Study of the Thermal Performance of Two Thermosiphon Solar Water Heaters System

2020 ◽  
Vol 9 (3) ◽  
pp. 401-410
Author(s):  
Blaise Kamenan Koua ◽  
Paul Magloire Ekoun Koffi ◽  
Prosper Gbaha

 The aim of this study is to present the comparative results of experimental investigations of the thermal performance of two thermosiphon solar water heaters system (SWHS). The first uses the coconut fiber (CF), a local vegetable and the second, the glass wool (GW), an imported and expensive material, as thermal insulations. The maximum instantaneous efficiencies are, respectively, 65.30 % and 58.7% with glass wool and coconut fiber while the mass flow rate values are, respectively, 0.0098 kg/s and 0.0078 kg/s with glass wool and coconut fiber. In addition, the calculated average values of F’(τα) and F’UL are, respectively, 0.79 and 5.86 Wm-2°C for the coconut fiber collector and 0.8 and 5.26 Wm-2°C for the glass wool collector. The average heat exchanger effectiveness obtained for the two SWHS are superior to 50%. As an environment-friendly and renewable material, coconut fiber is particularly suitable for thermal insulation in order to save energy. The experimental results show the ability of the constructed solar water heater in providing hot water suitable for maternity, hotels, households and encourage its implementation and utilization on a broad scale. The SWHS can be used in any weather conditions. ©2020. CBIORE-IJRED. All rights reserved

2019 ◽  
Vol 8 (1) ◽  
Author(s):  
M.J.R Abdunnabi ◽  
D.L D.L. Loveday ◽  
J.A Wright

Thermosyphon solar water heaters can be considered the most popular solar technology for supplying households with the needed hot water for domestic purposes. However, sizing these systems is mainly based on experience and trial methods, these methods were established more on intuition instead of scientific approaches. This paper is aimed at studying the sizing of thermosyphon systems through the development of a dedicated generic design tool. The tool can be utilized by manufacturers and engineers to arrive at optimized systems designed according to the operating and weather conditions of certain geographical locations. The design tool is implemented in this study to find the optimum system design that fits households in Libya (as a case study in this work) and accounts for the weather conditions of Tripoli and a simple, but representative, hot water load pattern. Two different sizes of thermosyphon systems covers hot water load of 180 lit and 240 lit, and two different configurations with vertical and horizontal tanks are studied and the best fit designs are obtained. The design tool has shown a great potential, and with further development and validation would be capable of widespread commercial application.


2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Mehdi Jahangiri ◽  
Esther T. Akinlabi ◽  
Sam M. Sichilalu

Solar water heaters (SWHs) are one of the most effective plans for general and easy use of solar energy to supply hot water in domestic and industrial sectors. This paper gives the first-ever attempts to assess the optimal localization of SWHs across 22 major cities in Zambia, as well as determine the possibility of hot water generation and model the greenhouse gas (GHG) emission saving. The climate data used is extracted by using the MeteoSyn software which is modeled in TSOL™. Results show the high potential of GHG emission reduction due to nonconsumption of fossil fuels owing to the deployment of SWHs, and three cities Kabwe, Chipata, and Mbala had the highest GHG mitigation by 1552.97 kg/y, 1394.8 kg/y, and 1321.39 kg/y, respectively. On average, SWHs provide 62.47% of space heating and 96.05% of the sanitary hot water requirement of consumers. The findings have shown the potential for the deployment of SWHs in Zambia. The techno-enviro study in this paper can be used by the policymakers of Zambia and countries with similar climates.


2013 ◽  
Vol 860-863 ◽  
pp. 81-87
Author(s):  
Yu Qin Yang ◽  
Run Sheng Tang

In the present specification of domestic solar water heating systems (GB/T19141), regardless of the type of collectors used in the systems, Q17, the daily heat gain corresponding to the daily radiation of 17MJ/m2 on the collector surface, is a key indication to rate the thermal performance of a domestic solar water heaters. In this work, an attempt was made to investigate effect of the distance between two adjacent tubes in solar tube collectors of a water-in-glass evacuated tube solar water heater (ETSWH) on by theoretical calculations and experimental measurements. Results obtained by simulations and experimental test showed that the tube space had a significant effect on of the ETSWH, the shorter the tube distance, the higher the Q17, thus better the ETSWH performs. However, the actual situation is the case, the shorter the tube distance, the lower the real daily solar gain of the system, thus worse it performs. This implied that Q17 as the indication of thermal performance of the ETSWH is not reasonable, and specifying the tube distance in solar tube collectors of the ETSWH in the technical specification of GB/T19141 is advisable so as to eliminate effect of the tube distance on Q17.


Inventions ◽  
2020 ◽  
Vol 6 (1) ◽  
pp. 4
Author(s):  
Fatima Zohra Gargab ◽  
Amine Allouhi ◽  
Tarik Kousksou ◽  
Haytham El-Houari ◽  
Abdelmajid Jamil ◽  
...  

This paper aims to highlight the potential of solar water heater installations in Morocco. The project involves the comparison of active and passive solutions for energy efficiency in buildings. To this end, a numerical simulation model of solar water heater installations is created under TRNsys. Three hot water demand scenarios (Low, Standard, and High) were taken into account for the six climatic zones defined in the Moroccan thermal regulation of constructions. The same software (TRNsys) is used to model a pilot building consisting of 16 flats. Energy efficiency actions have been applied to the building envelope (insulation and glazing) and simulations are made for the six areas. The simulation results comparing energy and financial savings show the influence of subsidized gas prices on solar water heaters’ relevance despite significant energy savings. This work proves that solar water heaters will be a primary obligation for Morocco, taking into account changes in butane gas prices.


2014 ◽  
Vol 3 (1) ◽  
pp. 92-100 ◽  
Author(s):  
Mourad Chikhi ◽  
Rabah Sellami ◽  
Nachida Kasbadji Merzouk

The development and use of renewable energy sources and technologies are becoming vital for the management of energy supply and demand. For development solar water heaters, the incentive programs are supported by the Algerian government to generalize the using of this kind of energy especially in Sahara. This study is a part of program to develop a new solar water heater in UDES (Algeria). In this research work, the thermal performance of a solar water heater with a mantle heat exchanger is investigated numerically using Comsol Multyphysics software. The objective is to investigate the influence of the mantle heat exchanger thickness on the performance of solar water heaters. The results show, for 160 liters capacity of the solar water heaters tank, the 13mm of the heat exchanger thickness leads to improve the efficiency of the solar water heater.


2018 ◽  
Vol 37 (3) ◽  
pp. 1147-1161 ◽  
Author(s):  
Esdras Nshimyumuremyi ◽  
Wang Junqi

Solar water heating is a technology of capturing the energy from the sun's radiation for the purpose of raising the temperature of water from water supply temperature to the desired higher temperature depending on the use. There are many views and discussions on the questions of thermal efficiency of solar water heaters and their associated cost, especially different customers/users want to replace their existing conventional water heating energy by solar water heating systems. In this present paper, a deep investigation has been accomplished to determine thermal efficiency and cost analysis of solar water heater made in Rwanda. During manufacturing of solar water heater, the collector was the main part to emphasize on. The high efficiency of the system was achieved by replacing galvanized iron sheet by aluminum sheet slotted and black painted as an absorber plate. The ambient temperature and average solar radiation of the three sites where solar water heaters are installed were investigated. The used materials, specifications and sizing were discussed in this paper.


2004 ◽  
Vol 126 (3) ◽  
pp. 950-956 ◽  
Author(s):  
J. M. Chang

The overall performance rating of a thermosyphon solar water heater should take into consideration its heat removal efficiency during the system application phase. This study employs a precise on-line operation to first identify physical heat removal patterns of a thermosyphon solar water heater, and then develops an empirical model for deriving its characteristic heat removal efficiency. This empirical model is in the form of a logarithmic curve, and has a high data correlation coefficient of 0.889 to 0.967. Based upon the empirical model, this study defines a characteristic heat removal efficiency parameter for thermosyphon solar water heaters. Finally, this study establishes a storage tank design method which enables the characteristic heat removal efficiency of the complete system to be optimized.


Green ◽  
2011 ◽  
Vol 1 (2) ◽  
Author(s):  
Brian Norton

AbstractSolar water heating can be considered to be an established mature technology. The achievement of this status is the outcome of over a century of system development that culminated with a flourish of innovation in the last thirty years. Drivers for research and development have been achieving economic viability by devising systems that, for specific applications in particular climate contexts produced more hot water per unit cost. Reductions in both initial capital and installation costs have been achieved as well as in those associated with subsequent operation and maintenance. Research on solar water heating is discussed with the emphasis on overall systems though some key aspects of component development are also outlined. A comprehensive taxonomy is presented of the generic types of solar water heater that have emerged and their features, characteristics and performance are discussed.


1983 ◽  
Vol 62 (1) ◽  
pp. 38-51
Author(s):  
Ken Butti ◽  
John Perlin

Author(s):  
Ouhammou Badr ◽  
Azeddine Frimane ◽  
Aggour Mohammed ◽  
Brahim Daouchi ◽  
Abdellah Bah ◽  
...  

The Indirect Solar Water Heater System (SWHS) with Forced Circulation is modeled by proposing a theoretical dynamic multi-node model. The SWHS, which works with a 1,91 m<sup>2</sup> PFC and 300 L storage tank, and it is equipped with available forced circulation scale system fitted with an automated sub-system that controlled hot water, is what the experimental setup consisted of. The system, which 100% heated water by only using solar energy. The experimental weather conditions are measured every one minute. The experiments validation steps were performed for two periods, the first one concern the cloudy days in December, the second for the sunny days in May; the average deviations between the predicted and the experimental values is 2 %, 5 % for the water temperature output and for the useful energy  are 4 %, 9 % respectively for the both typical days, which is very satisfied. The thermal efficiency was determined experimentally and theoretically and shown to agree well with the EN12975 standard for the flow rate between 0,02 kg/s and 0,2kg/s.


Sign in / Sign up

Export Citation Format

Share Document