An overlap-based human gait cycle detection

2019 ◽  
Vol 11 (2) ◽  
pp. 148 ◽  
Author(s):  
K. Sugandhi ◽  
Farha Fatina Wahid ◽  
P. Nikesh ◽  
G. Raju
2019 ◽  
Vol 11 (2) ◽  
pp. 148
Author(s):  
G. Raju ◽  
P. Nikesh ◽  
Farha Fatina Wahid ◽  
K. Sugandhi

2016 ◽  
Vol 35 (3) ◽  
pp. 21-28
Author(s):  
Anatoly S. Bobe ◽  
◽  
Dmitry V. Konyshev ◽  
Sergey A. Vorotnikov ◽  
◽  
...  
Keyword(s):  

Author(s):  
Antonino Proto ◽  
Benish Fida ◽  
Ivan Bernabucci ◽  
Daniele Bibbo ◽  
Silvia Conforto ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7497
Author(s):  
Roy T. Shahar ◽  
Maayan Agmon

Spatio-temporal parameters of human gait, currently measured using different methods, provide valuable information on health. Inertial Measurement Units (IMUs) are one such method of gait analysis, with smartphone IMUs serving as a good substitute for current gold-standard techniques. Here we investigate the concurrent validity of a smartphone placed in a front-facing pocket to perform gait analysis. Sixty community-dwelling healthy adults equipped with a smartphone and an application for gait analysis completed a 2-min walk on a marked path. Concurrent validity was assessed against an APDM mobility lab (APDM Inc.; Portland, OR, USA). Bland–Altman plots and intraclass correlation coefficients (agreement and consistency) for gait speed, cadence, and step length indicate good to excellent agreement (ICC2,1 > 0.8). For right leg stance and swing % of gait cycle and double support % of gait cycle, results were moderate (0.52 < ICC2,1 < 0.62). For left leg stance and swing % of gait cycle left results show poor agreement (ICC2,1 < 0.5). Consistency of results was good to excellent for all tested parameters (ICC3,1 > 0.8). Thus we have a valid and reliable instrument for measuring healthy adults’ spatio-temporal gait parameters in a controlled walking environment.


2020 ◽  
Vol 15 (3) ◽  
pp. 3-14
Author(s):  
Péter Müller ◽  
Ádám Schiffer

Examining a human movement can provide a wealth of information about a patient’s medical condition. The examination process can be used to diagnose abnormal changes (lesions), ability development and monitor the rehabilitation process of people with reduced mobility. There are several approaches to monitor people, among other things with sensors and various imaging and processing devices. In this case a Kinect V2 sensor and a self-developed LabView based application was used, to examine the movement of the lower limbs. The ideal gait pattern was recorded in the RoboGait training machine and the measured data was used to identify the phases of the human gait. During the evaluation, the position of the skeleton model, the associated body joints and angles can be calculated. The pre-recorded ideal and natural gait cycle can be compared.With the self-developed method the pre-recorded ideal and natural gait cycle can be compared and processed for further evaluation. The evaluated measurement data confirm that a reliable and mobile solution for gait analysis has been created.


Author(s):  
Mehmet Iscan ◽  
Cuneyt Yilmaz ◽  
Berkem Vural ◽  
Huseyin Eken

Abstract The most common human locomotion problems such as quadriceps weakness, knee osteoarthritis can be healed up by using exoskeleton mechanisms with proper control systems. However, these kinds of abnormalities cannot be easily modeled in terms of engineering perspectives due to a lack of adequate data or unknown dynamics. Also, nature always seeks minimum energy as well as biology which means that the unknown dynamics can be built by using this phenomenon. In this study, a new system dynamic model had been involved in designing a simple single-legged exoskeleton robot mechanism and its control system to assist partially disabled individuals to improve their quality of locomotion. To determine the specific features of the human gait disorders to interpret their nature in the computer-aided simulation environment, knee osteoarthritis and quadriceps weakness, which are the common types of such problems, have been chosen as the main interests for this study. By using the lower limb model with anthropometric data, the simulations of disorders have been realized on MATLAB Simscape environment which enables us to model the entire exoskeleton system with the 3D parts of the human body. A model of a leg with the disorder was able to be obtained with the utilization of feedback linearization which is one of the examples of minimum principles in the control theory. A proper gait cycle is achieved with the exoskeleton application and separately for the leg, with approximately 10 deg deviation from the natural property in knee flexion. Finally, it can be seen that the system conversion into such problematic cases with or without an exoskeleton system is accomplished.


Author(s):  
Yundong Xuan ◽  
Yingfei Sun ◽  
Zhibei Huang ◽  
Zhan Zhao ◽  
Zhen Fang ◽  
...  

2019 ◽  
Vol 74 ◽  
pp. 128-134 ◽  
Author(s):  
Hui Xing Tan ◽  
Nway Nway Aung ◽  
Jing Tian ◽  
Matthew Chin Heng Chua ◽  
Youheng Ou Yang

Sign in / Sign up

Export Citation Format

Share Document