human gait
Recently Published Documents


TOTAL DOCUMENTS

1554
(FIVE YEARS 416)

H-INDEX

64
(FIVE YEARS 7)

2022 ◽  
Vol 15 ◽  
Author(s):  
Namita Anil Kumar ◽  
Shawanee Patrick ◽  
Woolim Hong ◽  
Pilwon Hur

User customization of a lower-limb powered Prosthesis controller remains a challenge to this date. Controllers adopting impedance control strategies mandate tedious tuning for every joint, terrain condition, and user. Moreover, no relationship is known to exist between the joint control parameters and the slope condition. We present a control framework composed of impedance control and trajectory tracking, with the transitioning between the two strategies facilitated by Bezier curves. The impedance (stiffness and damping) functions vary as polynomials during the stance phase for both the knee and ankle. These functions were derived through least squares optimization with healthy human sloped walking data. The functions derived for each slope condition were simplified using principal component analysis. The weights of the resulting basis functions were found to obey monotonic trends within upslope and downslope walking, proving the existence of a relationship between the joint parameter functions and the slope angle. Using these trends, one can now design a controller for any given slope angle. Amputee and able-bodied walking trials with a powered transfemoral prosthesis revealed the controller to generate a healthy human gait. The observed kinematic and kinetic trends with the slope angle were similar to those found in healthy walking.


Author(s):  
Mehmet Iscan ◽  
Cuneyt Yilmaz ◽  
Berkem Vural ◽  
Huseyin Eken

Abstract The most common human locomotion problems such as quadriceps weakness, knee osteoarthritis can be healed up by using exoskeleton mechanisms with proper control systems. However, these kinds of abnormalities cannot be easily modeled in terms of engineering perspectives due to a lack of adequate data or unknown dynamics. Also, nature always seeks minimum energy as well as biology which means that the unknown dynamics can be built by using this phenomenon. In this study, a new system dynamic model had been involved in designing a simple single-legged exoskeleton robot mechanism and its control system to assist partially disabled individuals to improve their quality of locomotion. To determine the specific features of the human gait disorders to interpret their nature in the computer-aided simulation environment, knee osteoarthritis and quadriceps weakness, which are the common types of such problems, have been chosen as the main interests for this study. By using the lower limb model with anthropometric data, the simulations of disorders have been realized on MATLAB Simscape environment which enables us to model the entire exoskeleton system with the 3D parts of the human body. A model of a leg with the disorder was able to be obtained with the utilization of feedback linearization which is one of the examples of minimum principles in the control theory. A proper gait cycle is achieved with the exoskeleton application and separately for the leg, with approximately 10 deg deviation from the natural property in knee flexion. Finally, it can be seen that the system conversion into such problematic cases with or without an exoskeleton system is accomplished.


2022 ◽  
Vol 1 (2) ◽  
pp. 65-72
Author(s):  
Ade Reza Ismawan ◽  
Rifky Ismail ◽  
Tony Prahasto ◽  
Mochammad Ariyanto ◽  
Budi Setiyana

Transtibial and transfemoral amputations are the most common amputations in the world, loss of lower extremity result in impaired function extremities and also body balance. A prosthesis is a medical device designed to replace a specific body part to restore function to a body part lost due to an accident or disease. Most doctors strongly recommend the use of a prosthesis so that patients can return to normal activities after undergoing an amputation. Besides functioning to support beauty, the use of prostheses is also to restore the quality of life of prosthetic users, the issue of metabolic energy consumption when walking is also very important in designing transtibial bionic prosthesis because it involves the comfort of the user transtibial prosthesis. Most of the existing transtibial prosthesis products in Indonesia are conventional passive transtibial foot products, and passive prosthesis users show a limp or asymmetrical gait pattern so that conventional passive prosthesis users experience discomfort when walking in the form of pain in the amputated leg and normal foot, which can cause secondary musculoskeletal injuries such as joint disorders. Passive prostheses cannot generate propulsive force during push-off phase (terminal stance and preswing) of the human gait cycle. The use of passive prostheses can also consume 20-30% more metabolic energy while walking so that it can cause fatigue for the user. Transtibial bionic prosthesis research is growing, transtibial bionic prosthesis can overcome the weakness of passive prosthesis because it can produce push-off during gait cycle and several researchers have shown that bionic prostheses are capable of mimicking the human gait, as well as improve the  performance in a more natural gait and normal walking. This study aims to study the existing transtibial bionic prosthesis by comparing between 6 existing designs of powered ankle or transtibial bionic prosthesis that have been published in several publications. The discussion focuses on the design and mechanical systems, actuators related to the selection of motors and drive mechanisms as well as power transmission from actuators to moving components.


2022 ◽  
Vol 12 ◽  
Author(s):  
Aditya Viswakumar ◽  
Venkateswaran Rajagopalan ◽  
Tathagata Ray ◽  
Pranitha Gottipati ◽  
Chandu Parimi

Gait analysis is used in many fields such as Medical Diagnostics, Osteopathic medicine, Comparative and Sports-related biomechanics, etc. The most commonly used system for capturing gait is the advanced video camera-based passive marker system such as VICON. However, such systems are expensive, and reflective markers on subjects can be intrusive and time-consuming. Moreover, the setup of markers for certain rehabilitation patients, such as people with stroke or spinal cord injuries, could be difficult. Recently, some markerless systems were introduced to overcome the challenges of marker-based systems. However, current markerless systems have low accuracy and pose other challenges in gait analysis with people in long clothing, hiding the gait kinematics. The present work attempts to make an affordable, easy-to-use, accurate gait analysis system while addressing all the mentioned issues. The system in this study uses images from a video taken with a smartphone camera (800 × 600 pixels at an average rate of 30 frames per second). The system uses OpenPose, a 2D real-time multi-person keypoint detection technique. The system learns to associate body parts with individuals in the image using Convolutional Neural Networks (CNNs). This bottom-up system achieves high accuracy and real-time performance, regardless of the number of people in the image. The proposed system is called the “OpenPose based Markerless Gait Analysis System” (OMGait). Ankle, knee, and hip flexion/extension angle values were measured using OMGait in 16 healthy volunteers under different lighting and clothing conditions. The measured kinematic values were compared with a standard video camera based normative dataset and data from a markerless MS Kinect system. The mean absolute error value of the joint angles from the proposed system was less than 90 for different lighting conditions and less than 110 for different clothing conditions compared to the normative dataset. The proposed system is adequate in measuring the kinematic values of the ankle, knee, and hip. It also performs better than the markerless systems like MS Kinect that fail to measure the kinematics of ankle, knee, and hip joints under dark and bright light conditions and in subjects with long robe clothing.


2022 ◽  
Vol 8 ◽  
Author(s):  
Elsa J. Harris ◽  
I-Hung Khoo ◽  
Emel Demircan

We performed an electronic database search of published works from 2012 to mid-2021 that focus on human gait studies and apply machine learning techniques. We identified six key applications of machine learning using gait data: 1) Gait analysis where analyzing techniques and certain biomechanical analysis factors are improved by utilizing artificial intelligence algorithms, 2) Health and Wellness, with applications in gait monitoring for abnormal gait detection, recognition of human activities, fall detection and sports performance, 3) Human Pose Tracking using one-person or multi-person tracking and localization systems such as OpenPose, Simultaneous Localization and Mapping (SLAM), etc., 4) Gait-based biometrics with applications in person identification, authentication, and re-identification as well as gender and age recognition 5) “Smart gait” applications ranging from smart socks, shoes, and other wearables to smart homes and smart retail stores that incorporate continuous monitoring and control systems and 6) Animation that reconstructs human motion utilizing gait data, simulation and machine learning techniques. Our goal is to provide a single broad-based survey of the applications of machine learning technology in gait analysis and identify future areas of potential study and growth. We discuss the machine learning techniques that have been used with a focus on the tasks they perform, the problems they attempt to solve, and the trade-offs they navigate.


Author(s):  
Andrii Shachykov ◽  
Julien Frere ◽  
Patrick Henaff
Keyword(s):  

2022 ◽  
Vol 70 (2) ◽  
pp. 2113-2130
Author(s):  
Awais Khan ◽  
Muhammad Attique Khan ◽  
Muhammad Younus Javed ◽  
Majed Alhaisoni ◽  
Usman Tariq ◽  
...  

2022 ◽  
Vol 70 (1) ◽  
pp. 343-360
Author(s):  
Asif Mehmood ◽  
Muhammad Attique Khan ◽  
Usman Tariq ◽  
Chang-Won Jeong ◽  
Yunyoung Nam ◽  
...  

Author(s):  
Ahasan Atick Faisal ◽  
Muhammad E.H. Chowdhury ◽  
Amith Khandakar ◽  
Shafayet Hossain ◽  
Mohammed Alhatou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document