scholarly journals Analysis of particle size and fractal dimensions of suspensions contained in raw sewage, treated sewage and activated sludge

2016 ◽  
Vol 42 (3) ◽  
pp. 67-76 ◽  
Author(s):  
Magdalena Kuśnierz ◽  
Paweł Wiercik

Abstract The analysis of particle size in suspensions carried out with use of the laser diffraction method enables us to obtain not only information about the size of particles, but also about their properties, shape and spatial structure, determined basing on fractal dimension. The fractal dimension permits the evaluation of the interior of aggregates, at the same time showing the degree of complexity of the matter. In literature, much attention is paid to the evaluation of the fractal dimension of flocs in activated sludge, in the aspect of control of single processes, i.e. sedimentation, dehydration, coagulation or flocculation. However, results of research concerning the size of particles and the structure of suspensions existing in raw and treated sewage are still lacking. The study presents optical fractal dimensions D3 and particle size distributions measured with use of laser granulometer in raw and treated sewage and activated sludge collected from six mechanical-biological wastewater treatment plants located in the Lower Silesian region. The obtained test results demonstrate that wastewater treatment plants that use both sequencing batch reactors and continuous flow reactors are more efficient at capturing suspension particles of a size up to 30 μm and are characterized by an increased removal of particles of a size ranging from 30 μm to 550 μm to the outflow. Additionally, in the case of samples of treated sewage and activated sludge collected at the same location, at short intervals, similar particle distributions were observed. As far as the analysis of fractal dimensions is concerned, particles contained in the raw sewage suspension were characterized by the lowest values of the fractal dimension (median equals 1.89), while the highest values occurred in particles of activated sludge (median equals 2.18). This proves that the spatial structure of suspension particles contained in raw sewage was similar to a linear structure, with a large amount of open spaces, while the structure of particles contained in the activated sludge suspension was significantly more complex in the spatial aspect.

2004 ◽  
Vol 50 (7) ◽  
pp. 249-255 ◽  
Author(s):  
Z. Bejvl ◽  
P. Matuška ◽  
J. Stara ◽  
P. Chudoba

The evolution of Czech standards requires higher efficiency of nutrient removal from municipal wastewaters. At the beginning of the last decade of 20th century, a new activated sludge configuration called R-AN-D-N process has been described, successfully tested and now largely used at several wastewater treatment plants (WWTP) in the Czech republic. The main feature of the R-AN-D-N process is the introduction of a regeneration zone in sludge recycle, which enables to increase sludge age in the system without any substantial increase in WWTP volume. Performances of three Czech large WWTP with R-AN-D-N configuration have been monitored and compared within a period of one and a half years. The results confirmed excellent nutrient removal efficiency for wastewaters with different proportion between sewage and industrial effluents. Two of three monitored WWTP received wastewaters from breweries (Budweiser and Pilsner Urquell). The settleability of activated sludge from all three WWTP was correct, with SVI values usually ranging from 50 to 150 ml/g. Monitoring of sludge composition indicated proliferation of several filamentous bacteria, particularly types 0581, 0092 and M. parvicella. No severe bulking events were observed. Finally, the operational costs expressed in CZK (Czech crown: 1CZK = €0.0322) per cubic metre of treated sewage or per capita amounts respectively from 2.24 to 6.52, and from 285 to 342.


2017 ◽  
Vol 9 (4) ◽  
pp. 413-418
Author(s):  
Aušra Mažeikienė ◽  
Julita Starenko

It is important to control not only the large wastewater treatment plants work, but also the work of individual small wastewater treatment plants for the protection of environment. Individual small wastewater treatment plants can become the local sources of pollution, when they are not functioning properly. Sewage purification indicators are not always the same as declared at wastewater treatment plants documentation in real conditions, so it is important to control the properly work of individual small wastewater treatment plants. The work of the small wastewater treatment plant AT-6 was analyzed by the treated sewage results (BDS7, SM, NH4-N, NO3-N, NO2-N, PO4-P), the quality of activated sludge, biological indicators and enzymatic activity in this article. The nitrification process was not going very well by the results of research, because there was the 72 mg/l concentration of ammonium nitrogen remaining in the cleaned wastewater. The morphological study of the activated sludge has confirmed the hypothesis that the necessary conditions for nitrification process were not established. The oxygen supply was increased and the small wastewater treatment plant functioning become more efficient, because nitrification process started working properly – there was less than 1 mg/l of ammonium nitrogen remaining in the cleaned wastewater.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Young Kyung Kim ◽  
Keunje Yoo ◽  
Min Sung Kim ◽  
Il Han ◽  
Minjoo Lee ◽  
...  

Abstract Bacterial communities in wastewater treatment plants (WWTPs) affect plant functionality through their role in the removal of pollutants from wastewater. Bacterial communities vary extensively based on plant operating conditions and influent characteristics. The capacity of WWTPs can also affect the bacterial community via variations in the organic or nutrient composition of the influent. Despite the importance considering capacity, the characteristics that control bacterial community assembly are largely unknown. In this study, we discovered that bacterial communities in WWTPs in Korea and Vietnam, which differ remarkably in capacity, exhibit unique structures and interactions that are governed mainly by the capacity of WWTPs. Bacterial communities were analysed using 16S rRNA gene sequencing and exhibited clear differences between the two regions, with these differences being most pronounced in activated sludge. We found that capacity contributed the most to bacterial interactions and community structure, whereas other factors had less impact. Co-occurrence network analysis showed that microorganisms from high-capacity WWTPs are more interrelated than those from low-capacity WWTPs, which corresponds to the tighter clustering of bacterial communities in Korea. These results will contribute to the understanding of bacterial community assembly in activated sludge processing.


Author(s):  
Hisashi Satoh ◽  
Yukari Kashimoto ◽  
Naoki Takahashi ◽  
Takashi Tsujimura

A deep learning-based two-label classifier 1 recognized a 20% morphological change in the activated flocs. Classifier-2 quantitatively recognized an abundance of filamentous bacteria in activated flocs.


1999 ◽  
Vol 40 (11-12) ◽  
pp. 223-229 ◽  
Author(s):  
Frédéric Clauss ◽  
Christel Balavoine ◽  
Delphine Hélaine ◽  
Gaëtan Martin

Forest industry wastewaters are difficult to clean: hydraulic and organic load variations, filamentous bulking or pin-point flocs negatively impact depollution processes. The addition of a fine, mineral, talc-based powder, Aquatal, into the aeration tanks of wastewater treatment plants connected to pulp and paper factories has been successfully tested since end of '97. The first case-study presents full results obtained over a period of 18 months in a 20,000 p.e. plant connected to a paper factory. The mineral powder was regularly added to control sludge volume index, thereby ensuring low suspended solids concentration in the outfluent. Plant operators could easily adapt biomass concentration to match organic load variation, thereby maintaining pollution micro-organisms ratio constant. In a second case study, a trouble-shooting strategy was implemented to counteract filamentous bulking. A one-off, large dosage enabled the plant operator to deal effectively with poor settleability sludge and rapidly control sludge blanket expansion. In both cases, the main common characteristics observed were an increase in floc aggregation and the production of heavier and well-structured flocs. The sludge settling velocity increased and an efficient solid/liquid separation was obtained. After a few days, the mineral particles of Aquatal were progressively integrated into the sludge floc structure. When the mineral powder was added to the activated sludge in the aeration basin, chemical interactions frequently encountered with other wastewater treatment additives did not pose a problem. Moreover, with this mineral additive, the biological excess sludge displayed good thickening properties and dewatering was improved. Despite the addition of the insoluble mineral particles, the amount of wet sludge expelled did not increase. Aquatal offers a rapid solution to floc settleability problems which so frequently arise when physical or biological disorders appear in forest industry wastewater treatment plants.


1994 ◽  
Vol 30 (4) ◽  
pp. 211-214 ◽  
Author(s):  
E. Brands ◽  
M. Liebeskind ◽  
M. Dohmann

This study shows a comparison of important parameters for dynamic simulation concerning the highrate and low-rate activated sludge tanks of several municipal wastewater treatment plants. The parameters for the dynamic simulation of the single-stage process are quite well known, but parameters for the high-ratellow-rate activated sludge process are still missi ng, although a considerable number of wastewater treatment plants are designed and operated that way. At present any attempt to simulate their operation is restricted to the second stage due to missing data concerning growth rate, decay rate, yield coefficient and others.


1992 ◽  
Vol 25 (6) ◽  
pp. 125-139 ◽  
Author(s):  
J. Kappeler ◽  
W. Gujer

To predict the behaviour of biological wastewater treatment plants, the Activated Sludge Model No. 1 is often used. For the application of this model kinetic parameters and wastewater composition must be known. A simple method to estimate kinetic parameters of heterotrophic biomass and COD wastewater fractions is presented. With three different types of batch-tests these parameters and fractions can be determined by measuring oxygen respiration. Our measurements showed that the maximum specific growth rate µmax of heterotrophic biomass depends on temperature, reactor configuration and SRT. In typical wastewater treatment plants of Switzerland the amount of readily biodegradable substrate was generally small (about 9 % of the COD in primary effluent). The same method can also be used to determine kinetic parameters of nitrifying biomass.


Sign in / Sign up

Export Citation Format

Share Document