scholarly journals Preanalytical challenges – time for solutions

2019 ◽  
Vol 57 (7) ◽  
pp. 974-981 ◽  
Author(s):  
Giuseppe Lippi ◽  
Fay Betsou ◽  
Janne Cadamuro ◽  
Michael Cornes ◽  
Michael Fleischhacker ◽  
...  

Abstract The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE) was originally established in 2013, with the main aims of (i) promoting the importance of quality in the preanalytical phase of the testing process, (ii) establishing best practices and providing guidance for critical activities in the preanalytical phase, (iii) developing and disseminating European surveys for exploring practices concerning preanalytical issues, (iv) organizing meetings, workshops, webinars or specific training courses on preanalytical issues. As education is a core activity of the WG-PRE, a series of European conferences have been organized every second year across Europe. This collective article summarizes the leading concepts expressed during the lectures of the fifth EFLM Preanalytical Conference “Preanalytical Challenges – Time for solutions”, held in Zagreb, 22–23 March, 2019. The topics covered include sample stability, preanalytical challenges in hematology testing, feces analysis, bio-banking, liquid profiling, mass spectrometry, next generation sequencing, laboratory automation, the importance of knowing and measuring the exact sampling time, technology aids in managing inappropriate utilization of laboratory resources, management of hemolyzed samples and preanalytical quality indicators.

2019 ◽  
Vol 29 (2) ◽  
pp. 322-333 ◽  
Author(s):  
Janne Cadamuro ◽  
Michael Cornes ◽  
Ana-Maria Simundic ◽  
Barbara de la Salle ◽  
Gunn B.B. Kristensen ◽  
...  

Introduction: Compared to other activities of the testing process, the preanalytical phase is plagued by a lower degree of standardization, which makes it more vulnerable to errors. With the aim of providing guidelines and recommendations, the EFLM WG-PRE issued a survey across European medical laboratories, to gather information on local preanalytical practices. This is part one of two coherent articles, which covers all practices on monitoring preanalytical quality except haemolysis, icterus and lipemia (HIL). Materials and methods: An online survey, containing 39 questions dealing with a broad spectrum of preanalytical issues, was disseminated to EFLM member countries. The survey included questions on willingness of laboratories to engage in preanalytical issues. Results: Overall, 1405 valid responses were received from 37 countries. 1265 (94%) responders declared to monitor preanalytical errors. Assessment, documentation and further use of this information varied widely among respondents and partially among countries. Many responders were interested in a preanalytical online platform, holding information on various aspects of the preanalytical phase (N = 1177; 87%), in a guideline for measurement and evaluation of preanalytical variables (N = 1235; 92%), and in preanalytical e-learning programs or webinars (N = 1125; 84%). Fewer responders were interested in, or already participating in, preanalytical EQA programs (N = 951; 71%). Conclusion: Although substantial heterogeneity was found across European laboratories on preanalytical phase monitoring, the interest in preanalytical issues was high. A large majority of participants indicated an interest in new guidelines regarding preanalytical variables and learning activities. This important data will be used by the WG-PRE for providing recommendations on the most critical issues.


2017 ◽  
Vol 55 (1) ◽  
pp. 27-31 ◽  
Author(s):  
Michael Cornes ◽  
Edmée van Dongen-Lases ◽  
Kjell Grankvist ◽  
Mercedes Ibarz ◽  
Gunn Kristensen ◽  
...  

AbstractIt has been well reported over recent years that most errors within the total testing process occur in the pre-analytical phase (46%–68.2%), an area that is usually outside of the direct control of the laboratory and which includes sample collection (phlebotomy). National and international (WHO, CLSI) guidelines recommend that the order of draw of blood during phlebotomy should be blood culture/sterile tubes, then plain tubes/gel tubes, then tubes containing additives. This prevents contamination of sample tubes with additives from previous tubes that could cause erroneous results. There have been a number of studies recently looking at whether order of draw remains a problem with modern phlebotomy techniques and materials, or it is an outdated practice followed simply because of historical reasons. In the following article, the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) provides an overview and summary of the literature with regards to order of draw in venous blood collection. Given the evidence presented in this article, the EFLM WG-PRE herein concludes that a significant frequency of sample contamination does occur if order of draw is not followed during blood collection and when performing venipuncture under less than ideal circumstances, thus putting patient safety at risk. Moreover, given that order of draw is not difficult to follow and knowing that ideal phlebotomy conditions and protocols are not always followed or possible, EFLM WG-PRE supports the continued recommendation of ensuring a correct order of draw for venous blood collection.


Author(s):  
Giuseppe Lippi ◽  
Michael P. Cornes ◽  
Kjell Grankvist ◽  
Mads Nybo ◽  
Ana-Maria Simundic

AbstractThe selection or procurement of blood collection devices in healthcare facilities is often an underestimated issue. This is probably due to different factors including the lack of knowledge of policymakers, hospital administrators and even laboratory managers about the importance of preanalytical quality and phlebotomy process, as well as to the absence of reliable guidelines or recommendations on how to precisely assess the quality of blood collection devices around the globe. With the awareness that a gap remains between manufacturers’ and local validation of blood collection devices, the Working Group for Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has drafted a consensus document aimed to provide a set of essential requisites, technical criteria (e.g. presence of physical defects, malfunctioning, safety problems) and clinical issues for supporting laboratory professionals in organization blood collection tubes tenders and validating new devices before local routine implementation. The laboratory professionals should also make sure that the tenders accurately and strictly define the responsibilities for validation experiments and the potential consequences in the case the validation outcome shows that tubes due not fulfill the expectations.


Author(s):  
Giuseppe Lippi ◽  
Geoffrey S. Baird ◽  
Giuseppe Banfi ◽  
Karin Bölenius ◽  
Janne Cadamuro ◽  
...  

Abstract It is now undeniable that laboratory testing is vital for the diagnosis, prognostication and therapeutic monitoring of human disease. Despite the many advances made for achieving a high degree of quality and safety in the analytical part of diagnostic testing, many hurdles in the total testing process remain, especially in the preanalytical phase ranging from test ordering to obtaining and managing the biological specimens. The Working Group for the Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has planned many activities aimed at mitigating the vulnerability of the preanalytical phase, including the organization of three European meetings in the past 7 years. Hence, this collective article follows the previous three opinion papers that were published by the EFLM WGPRE on the same topic, and brings together the summaries of the presentations that will be given at the 4th EFLM-BD meeting “Improving quality in the preanalytical phase through innovation” in Amsterdam, 24–25 March, 2017.


2018 ◽  
Vol 56 (10) ◽  
pp. 1660-1666 ◽  
Author(s):  
Giuseppe Lippi ◽  
Ana-Maria Simundic ◽  

Abstract The Working Group for the Preanalytical Phase (WG-PRE) was officially established by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) in 2013, with the aim of improving harmonization in the preanalytical phase across European member societies. Since its early birth, the WG-PRE has already completed a number of projects, including harmonizing the definition of fasting status, patient and blood tubes identification, color coding of blood collection tubes, sequence of tubes during blood drawing and participation in the development of suitable preanalytical quality indicators. The WG-PRE has also provided guidance on local validation of blood collection tubes, has performed two European surveys on blood sampling procedures and has organized four European meetings to promote the importance of quality in the preanalytical phase. The future activities entail development and validation of an external quality assessment scheme focused on preanalytical variables, development and dissemination of a survey about the local management of unsuitable samples in clinical laboratories, as well as release of EFLM phlebotomy guidelines. This article summarizes all recent achievements of the WG-PRE and illustrates future projects to promote harmonization in the preanalytical phase.


2020 ◽  
Vol 58 (10) ◽  
pp. 1655-1662
Author(s):  
Alexander von Meyer ◽  
Giuseppe Lippi ◽  
Ana-Maria Simundic ◽  
Janne Cadamuro

AbstractObjectivesAn accurate knowledge of blood collection times is crucial for verifying the stability of laboratory analytes. We therefore aimed to (i) assess if and how this information is collected throughout Europe and (ii) provide a list of potentially available solutions.MethodsA survey was issued by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Preanalytical Phase (WG-PRE) in 2017, aiming to collect data on preanalytical process management, including sampling time documentation, in European laboratories. A preceding pilot survey was disseminated in Austria in 2016. Additionally, preanalytical experts were surveyed on their local setting on this topic. Finally, the current scientific literature was reviewed on established possibilities of sampling time collection.ResultsA total number of 85 responses was collected from the pilot survey, whilst 1347 responses from 37 European countries were obtained from the final survey. A minority (i.e. ~13%) of responders to the latter declared they are unaware of the exact sampling time. The corresponding rate in Austria was ~70% in the pilot and ~30% in the final survey, respectively. Answers from 17 preanalytical experts from 16 countries revealed that sampling time collection seems to be better documented for out- than for in-patients. Eight different solutions for sample time documentation are presented.ConclusionsThe sample collection time seems to be documented very heterogeneously across Europe, or not at all. Here we provide some solutions to this issue and believe that laboratories should urgently aim to implement one of these.


Author(s):  
Giuseppe Lippi ◽  
Giuseppe Banfi ◽  
Stephen Church ◽  
Michael Cornes ◽  
Gabriella De Carli ◽  
...  

AbstractLaboratory diagnostics develop through different phases that span from test ordering (pre-preanalytical phase), collection of diagnostic specimens (preanalytical phase), sample analysis (analytical phase), results reporting (postanalytical phase) and interpretation (post-postanalytical phase). Although laboratory medicine seems less vulnerable than other clinical and diagnostic areas, the chance of errors is not negligible and may adversely impact on quality of testing and patient safety. This article, which continues a biennial tradition of collective papers on preanalytical quality improvement, is aimed to provide further contributions for pursuing quality and harmony in the preanalytical phase, and is a synopsis of lectures of the third European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)-Becton Dickinson (BD) European Conference on Preanalytical Phase meeting entitled ‘Preanalytical quality improvement. In pursuit of harmony’ (Porto, 20–21 March 2015). The leading topics that will be discussed include unnecessary laboratory testing, management of test request, implementation of the European Union (EU) Directive on needlestick injury prevention, harmonization of fasting requirements for blood sampling, influence of physical activity and medical contrast media on in vitro diagnostic testing, recent evidence about the possible lack of necessity of the order of draw, the best practice for monitoring conditions of time and temperature during sample transportation, along with description of problems emerging from inappropriate sample centrifugation. In the final part, the article includes recent updates about preanalytical quality indicators, the feasibility of an External Quality Assessment Scheme (EQAS) for the preanalytical phase, the results of the 2nd EFLM WG-PRE survey, as well as specific notions about the evidence-based quality management of the preanalytical phase.


Author(s):  
Kamil Taha Uçar ◽  
Abdulkadir Çat ◽  
Alper Gümüş ◽  
Nilhan Nurlu

Background: The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) have recommended an algorithm based on the reference change value (RCV) to evaluate hemolysis. We utilized this algorithm to analyze hemolysis-sensitive parameters. Methods: Two tubes of blood were collected from each of the 10 participants, one of which was subjected to mechanical trauma while the other was centrifuged directly. Subsequently, the samples were diluted with the participant's hemolyzed sample to obtain the desired hemoglobin concentrations (0, 1, 2, 4, 6, 8, and 10 g/L). ALT, AST, K, LDH, T.Bil tests were performed using Beckman Coulter AU680 analyzer. The analytical and clinical cut-offs were based on the biological variation for the allowable imprecision and RCV. The algorithms could report the values directly below the analytical cut-off or those between the analytical and clinical cut-offs with comments. If the change was above the clinical cut-off, the test was rejected. The linear regression was used for interferograms, and the hemoglobin concentrations corresponding to cut-offs were calculated via the interferograms. Results: The RCV was calculated as 29.6% for ALT. Therefore, ALT should be rejected in samples containing >5.9 g/L hemoglobin. The RCVs for AST, K, LDH, and T.Bil were calculated as 27.9%, 12.1%, 19.2%, and 61.2%, while the samples' hemoglobin concentrations for test rejection were 0.8, 1.6, 0.5, and 2.2 g/L, respectively. Conclusions: Algorithms prepared with RCV could provide evidence-based results and objectively manage hemolyzed samples.


Sign in / Sign up

Export Citation Format

Share Document