scholarly journals Comparison of silicon drift detectors made by Amptek and PNDetectors in application to the PHA system for W7-X

Nukleonika ◽  
2016 ◽  
Vol 61 (4) ◽  
pp. 409-412
Author(s):  
Natalia Krawczyk ◽  
Jacek Kaczmarczyk ◽  
Monika Kubkowska ◽  
Leszek Ryć

Abstract The paper presents comparison of two silicon drift detectors (SDD), one made by Amptek, USA, and the second one by PNDetector, Germany, which are considered for a soft X-ray diagnostic system for W7-X. The sensitive area of the first one is 7 mm2 × 450 μm and the second one is 10 mm2 × 450 μm. The first detector is cooled by a double-stage Peltier element, while the second detector is cooled by single-stage Peltier element. Each one is equipped with a field-effect transistor (FET). In the detector from Amptek, the FET is mounted separately, while in the detector from PNDetector, the FET is integrated on the chip. The nominal energy resolution given by the producers of the first and the second one is 136 [email protected] keV (at -50°C) and 132 [email protected] keV (at -20°C), respectively. Owing to many advantages, the investigated detectors are good candidates for soft X-ray measurements in magnetic confinement devices. They are suitable for soft X-ray diagnostics, like the pulse height analysis (PHA) system for the stellarator Wendelstein 7-X, which has been developed and manufactured at the Institute of Plasma Physics and Laser Microfusion (IPPLM), Warsaw, in collaboration with the Max Planck Institute for Plasma Physics (IPP), Greifswald. The diagnostic is important for the measurements of plasma electron temperature, impurities content, and possible suprathermal tails in the spectra. In order to choose the best type of detector, analysis of technical parameters and laboratory tests were done. Detailed studies show that the most suitable detector for the PHA diagnostics is the PNDetector.

2009 ◽  
Vol 80 (12) ◽  
pp. 126104 ◽  
Author(s):  
Y. P. Zhang ◽  
Yi Liu ◽  
J. W. Yang ◽  
X. Y. Song ◽  
M. Liao ◽  
...  

1965 ◽  
Vol 9 ◽  
pp. 354-364 ◽  
Author(s):  
D. W. Wilbur ◽  
J. W. Gofman

AbstractAn investigation has been made of the relative Kβ intensities in different chemical states of the sulfur atom using the Kα lines, with appropriate corrections, to provide the intensity standards. Both inorganic and organic compounds were included in the study. The data for each compound appear to be reliable to about ± 0.5%, while the whole series of compounds shows a variation greater than 20% in the corrected Kβ/Kα ratios. Energies were also measured, particularly the Kα energies, and their shifts were studied relative to the Kβ, intensity shifts. The work was done with a plane, single-crystal, helium-path spectrometer with proportional counter and pulse-height analysis for detection. The results are indicative of the usefulness of the method both in clarifying an uncertain chemical state and in studying the electronic structure of the bonded atom.


1960 ◽  
Vol 4 ◽  
pp. 370-381
Author(s):  
Kurt F.J. Heinrich

AbstractPulse-height analysis is a valuable tool in X-ray fluorescence analysis, both for qualitative and quantitative purposes. The elimination of higher order interferences permits determinations that would otherwise be very difficult or impossible, The systematic application of pulse-height analysis in qualitative work greatly simplifies the interpretation of complex spectra. In certain cases one can apply nondispersive analysis, relying on the pulse-height analyzer alone for separating energy levels of X-ray photons. Technique and limitations of pulse-height analysis will be discussed.


RADIOISOTOPES ◽  
1964 ◽  
Vol 13 (5) ◽  
pp. 355-361 ◽  
Author(s):  
Hiroshi IMAMURA ◽  
Kaoru UCHIDA ◽  
Hiroshi TOMINAGA

1990 ◽  
Vol 61 (10) ◽  
pp. 2801-2803 ◽  
Author(s):  
L. Carraro ◽  
M. Valisa

2018 ◽  
Vol 136 ◽  
pp. 58-62 ◽  
Author(s):  
Monika Kubkowska ◽  
Agata Czarnecka ◽  
Tomasz Fornal ◽  
Marta Gruca ◽  
Natalia Krawczyk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document