Potentiometric Determination of the Autoprotolysis Constants of Water–Dimethylsulfoxide Mixtures at Different Temperatures and Related Thermodynamic Quantities

1974 ◽  
Vol 88 (1-4) ◽  
pp. 149-159 ◽  
Author(s):  
Paolo Fiordiponti ◽  
Francesco Rallo ◽  
Fabrizio Rodante
1998 ◽  
Vol 16 (7) ◽  
pp. 557-564 ◽  
Author(s):  
Jinben Wang ◽  
Yao Lu ◽  
Buxing Han ◽  
Ming Dai ◽  
Haike Yan ◽  
...  

This paper describes the hydrophobic effect in the process of adsorption of alkyltrimethylammonium bromides from aqueous solution on to an activated carbon surface. Measurements of the adsorption isotherms of a series of alkyltrimethylammonium bromides with different hydrocarbon tail lengths at the activated carbon surface were carried out. In order to investigate the temperature dependence of the adsorption process, the determination of the adsorption of cetyltrimethylammonium bromide (CTAB) was undertaken at different temperatures in the range 20–60°C. From the experimental results obtained, the relevant thermodynamic quantities have been calculated. The role played by the hydrophobic effect in the adsorption process of cationic surfactants on to activated carbon and the factors affecting the adsorption mechanism were discussed.


1985 ◽  
Vol 54 (02) ◽  
pp. 533-538 ◽  
Author(s):  
Wilfried Thiel ◽  
Ulrich Delvos ◽  
Gert Müller-Berghaus

SummaryA quantitative determination of soluble fibrin in plasma was carried out by affinity chromatography. For this purpose, desAA-fibrin and fibrinogen immobilized on Sepharose 4B were used at the stationary side whereas batroxobin-induced 125I-desAA-fibrin or thrombin-induced 125I-desAABB-fibrin mixed with plasma containing 131I-fibrinogen represented the fluid phase. The binding characteristics of these mixtures to the immobilized proteins were compared at 20° C and 37° C. Complete binding of both types of fibrin to the immobilized desAA-fibrin was always seen at 20° C as well as at 37° C. However, binding of soluble fibrin was accompanied by substantial binding of fibrinogen that was more pronounced at 20° C. Striking differences depending on the temperature at which the affinity chromatography was carried out, were documented for the fibrinogen-fibrin interaction. At 20° C more than 90% of the applied desAA-fibrin was bound to the immobilized fibrinogen whereas at 37° C only a mean of 17% were retained at the fibrinogen-Sepharose column. An opposite finding with regard to the tested temperature was made with the desAABB-fibrin. Nearly complete binding to insolubilized fibrinogen was found at 37° C (95%) but only 58% of the desAABB-fibrin were bound at 20° C. The binding patterns did not change when the experiments were performed in the presence of calcium ions. The opposite behaviour of the two types of soluble fibrin to immobilized fibrinogen at the different temperatures, together with the substantial binding of fibrinogen in the presence of soluble fibrin to insolubilized fibrin in every setting tested, devaluates affinity chromatography as a tool in the quantitative assessment of soluble fibrin in patients’ plasma.


2016 ◽  
Vol 12 (3) ◽  
pp. 177-184 ◽  
Author(s):  
Gamal Abdel-Hafiz Mostafa ◽  
Mohammed Hefnawy ◽  
Mohammed Abounassif ◽  
Amer Alanazi ◽  
Abdulrahman Al-Majed ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3013
Author(s):  
Leszek Czechowski

The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis® System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature.


Sign in / Sign up

Export Citation Format

Share Document