Management of diabetic peripheral neuropathy (DPN) using low frequency pulsed electro magnetic field (LF-PEMF)

2017 ◽  
Author(s):  
Satish Chander Wasoori ◽  
Deepak G. Pande ◽  
Chetan Bhardwaj ◽  
Manoj Naik
2014 ◽  
Vol 556-562 ◽  
pp. 539-546
Author(s):  
Zhi Qiang Chen ◽  
Jian Wen ◽  
Hua Shang ◽  
Yuan Tang ◽  
Zheng Fang

Extremely low frequency electro-magnetic field (ELFF) exposure could induce hepatoma Bel-7402 and SMMC-7721 cells lines into early apoptosis without some significant effects to healthy hepatic cells HL-7702 cells in low exposure dose through affecting cellular membrane ion metabolism. Magnetic nanoFe3O4 particles (MNPs) presence with low effects to all hepatic cells lines strengthened ELFF bio-effects to tumor cells inducing more amount of tumor cells into early apoptosis with low effects to HL-7702 cells. Western-blot results indicated the early apoptosis signal channel Bcl protein family of tumor cells was activated significantly more effectively than HL-7702 cells due to higher MNPs uptake ratio of tumor cells and higher cellular membrane ion exchanging current than HL-7702 cells. Patch-clamp results showed MNPs combined with ELFF treatment inducing cells into early apoptosis should be partially based on ion metabolism disturbance of cells with similar to ELFF bio-effects to cells.


Author(s):  
Sajuni I ◽  
Karthika M ◽  
S Ezhilnila ◽  
Lalitha M. R. ◽  
Vishnuprasaath S.

Knee pain is one of the most frequent musculoskeletal problems among the middle-aged and elderly people and ‘Osteoarthritis’ is the widespread clinical pathology of the knee. Objective: The present study was conducted to evaluate whether low frequency Pulsed Electro Magnetic Field (PEMF) therapy is effective in patients with osteoarthritis knee using surface Electromyography (sEMG) of vastus medialis. Methods: The participants were subjected to Pulsed Electromagnetic Field Therapy using the PULSATRON  instrument designed by Madras Institute of Magnetobiology, Anna nagar. They were given PEMF therapy of 10 Hz for 60 minutes/ day for 21 days with a break after every 6 days. The participants of the study were subjected to Electromyography of vastus medialis using the MEDICAID PHYSIOPAC machine. The findings are compared before and after the duration of PEMF therapy. Results: The study shows that Low frequency PEMF (10 Hz) can be used as a treatment modality for Osteoarthritis. PEMF therapy, when given for a sufficient time (21 days) can improve the stiffness and the power of muscles as seen by the increase in amplitude of electromyography. The mean amplitude of sEMG in vastus medialis was found to be significantly increased (p <0.001) in the study group following the Pulsed Electro Magnetic Field (PEMF) therapy.


2012 ◽  
Vol 13 (6) ◽  
pp. 2961-2966 ◽  
Author(s):  
Balasubramanian Balamuralikrishnan ◽  
Vellingiri Balachandar ◽  
Shanmugam Suresh Kumar ◽  
Nattan Stalin ◽  
Prakash Varsha ◽  
...  

2020 ◽  
Vol 2020 (10) ◽  
pp. 4-11
Author(s):  
Victor Tikhomirov ◽  
Aleksandr Gorlenko ◽  
Stanislav Volohov ◽  
Mikhail Izmerov

The work purpose is the investigation of magnetic field impact upon properties of friction steel surfaces at fit stripping with tightness through manifested effects and their wear visually observed. On the spots of a real contact the magnetic field increases active centers, their amount and saturation with the time of dislocation outlet, and has an influence upon tribo-mating. The external electro-magnetic field promotes the increase of the number of active centers at the expense of dislocations outlet on the contact surface, and the increase of a physical contact area results in friction tie strengthening and growth of a friction factor. By the example of friction pairs of a spentonly unit in the suspension of coach cars there is given a substantiation of actuality and possibility for the creation of technical devices with the controlled factor of friction and the stability of effects achieved is also confirmed experimentally. Investigation methods: the fulfillment of laboratory physical experiments on the laboratory plant developed and patented on bush-rod samples inserted with the fit and tightness. The results of investigations and novelty: the impact of the magnetic field upon the value of a stripping force of a press fit with the guaranteed tightness is defined. Conclusion: there is a possibility to control a friction factor through the magnetic field impact upon a friction contact.


In a previous paper the absorption of γ-rays in the K-X-ray levels of the atom in which they are emitted was calculated according to the Quantum Mechanics, supposing the γ-rays to be emitted from a doublet of moment f ( t ) at the centre of the atom. The non-relativity wave equation derived from the relativity wave equation for an electron of charge — ε moving in an electro-magnetic field of vector potential K and scalar potential V is h 2 ∇ 2 ϕ + 2μ ( ih ∂/∂ t + εV + ih ε/μ c (K. grad)) ϕ = 0. (1) Suppose, however, that K involves the space co-ordinates. Then, (K. grad) ϕ ≠ (grad . K) ϕ , and the expression (K . grad) ϕ is not Hermitic. Equation (1) cannot therefore be the correct non-relativity wave equation for a single electron in an electron agnetic field, and we must substitute h 2 ∇ 2 ϕ + 2μ ( ih ∂/∂ t + εV) ϕ + ih ε/ c ((K. grad) ϕ + (grad. K) ϕ ) = 0. (2)


Galaxies ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 22
Author(s):  
Avijit K. Ganguly ◽  
Venktesh Singh ◽  
Damini Singh ◽  
Ankur Chaubey

In the presence of a thermal medium or an external electro-magnetic field, neutrinos can interact with photon, mediated by the corresponding charged leptons (real or virtual). The effect of a medium or an electromagnetic field is two-fold—to induce an effective [...]


Sign in / Sign up

Export Citation Format

Share Document