scholarly journals A Pulsatile Chest Mass After Bentall Procedure: A Case Report

2021 ◽  
Vol 24 (5) ◽  
pp. E794-E796
Author(s):  
Xiaofan Huang ◽  
Dashuai Wanga ◽  
Yu Songa ◽  
Long Wua

Aortic dissection is an aggressive and life-threatening cardiac disease that’s highly challenging in surgical operation. Bentall procedure comes with potential complications. How to manage these complications is important when it comes to improving patient outcome. In this case, we present a 41-year-old male patient with iatrogenic aortic dissection. He had aortic valve replacement and repair of an atrial septal defect in 2012. After five years, he suffered reoperation for aortic dissection. A year later, the patient was readmitted for a voluminous pulsatile mass over the anterior thorax, confirming the presence of a huge pseudoaneurysm originating from the left coronary bottom performed during the Bentall procedure. This required a third operation to repair the hemorrhagic site. Pseudoaneurysm is a common complication after the inclusion technique in the Bentall procedure. Effective hemostasis or tension-free anastomosis is important toward improving patient outcome.


Author(s):  
Xiaofan Huang ◽  
Dashuai Wang ◽  
Yu Song ◽  
Long Wu

Aortic dissection is an aggressive and life-threatening cardiac disease with highly challenging in surgical operation. Bentall procedure was potential complications. How to manage them would be important to improve patient outcomes. In this case, we present a 41-year-old male patient with iatrogenic aortic dissection. He had aortic valve replacement and repair of atrial septal defect in 2012. After 5 years, he suffered reoperation for aortic dissection. A year later the patient was readmitted for a voluminous pulsatile mass over the anterior thorax, confirming the presence of a huge pseudoaneurysm originating from the left coronary bottom performed during the Bentall procedure, requiring a third operation to repair the hemorrhagic site. The pseudoaneurysm was common complication after inclusion technique in Bentall procedure. How to effective hemostasis or tension-free anastomosis was important to improve patient outcomes.



Author(s):  
Rehan Shahid ◽  
◽  
Adnan Izhar ◽  
Ali Husnain ◽  
Anum Sohail ◽  
...  

Aortic dissection is intimal tear in aorta and collection of blood in between the layers of aortic wall. The incidence of acute type A aortic dissection is between 2.1 and 16.3 per 100,000 persons [1]. Aortic dissection is an infrequent but potentially life threatening complication of pregnancy with most of the cases occurring in third trimester and post-partum period [2]. The most important predisposing factors to aortic dissection are Marfan, Ehlers-Danlos, Turner and Loeys-Dietz syndromes [3]. However, the non sporadic cases can also occur in pregnancy [4].



2014 ◽  
Vol 17 (4) ◽  
pp. 196
Author(s):  
Erhan Kaya ◽  
Halit Yerebakan ◽  
Daniel Spielman ◽  
Omer Isik ◽  
Cevat Yakut

Occlusion of a coronary artery by an acute type A aortic dissection presents a life-threatening emergency that is rarely seen and easy to misdiagnose. We present the case of a 75-year-old male who experienced sudden onset of severe left-sided chest pain due to an acute type A aortic dissection that obstructed the right coronary artery. Following an initial misdiagnosis of acute coronary syndrome, imaging revealed the presence of an aortic dissection. An emergency modified Bentall procedure was performed, in which the damaged aorta and aortic valve were replaced.



2021 ◽  
Vol 51 (1) ◽  
pp. 10-15
Author(s):  
Kenneth V Iserson ◽  
Sri Devi Jagjit ◽  
Balram Doodnauth

Acute thoracic aortic dissection is an uncommon, although not rare, life-threatening condition. With protean signs and symptoms that often suggest more common cardiac or pulmonary conditions, it can be difficult to diagnose. Ultrasound has proven useful in making the correct diagnosis. This case demonstrates that training gained using standard ultrasound machines can be easily and successfully adapted to newer handheld ultrasound devices. The examination technique using the handheld device is illustrated with photos and a video.



2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zai-Qiang Zhang ◽  
Jia-Wang Ding

Abstract Background While the perforation of the atrial wall and aortic sinus after closure of an atrial septal defect (ASD) is rare, it’s life-threatening, with rapid progress and high mortality. To the best of our knowledge, 21 similar cases have been reported since 1976. Case presentation We report a 16-year-old male whose atrial septal defect (ASD) was closed using a 12-mm Amplatzer septal occluder (ASO). Atrial wall and aortic sinus perforation occurred 3 months after transcatheter closure, and the patient was discharged after emergency operation. He was discharged on the 12th postoperative day in good overall condition. Conclusions With this case report, we want to illustrate that although percutaneous closure of ASD is regarded as a routine procedure, we should not forget the potentially lethal complications, especially cardiac erosion. Therefore, we should carefully evaluate the risk of erosion before surgery, and careful lifelong follow-up is needed.



2009 ◽  
Vol 45 (2) ◽  
pp. 78-83 ◽  
Author(s):  
Alessia Diana ◽  
Carlo Guglielmini ◽  
Fabio Acocella ◽  
Flavio Valerio ◽  
Mario Cipone

Transudate pleural effusion associated with tricuspid dysplasia and ostium secundum-type atrial septal defect was diagnosed in a 14-month-old bullmastiff. Following administration of furosemide and an angiotensin-converting enzyme (ACE) inhibitor, the dog remained free of pleural effusion for 10 months, until he showed severe dyspnea due to chylothorax. Medical therapy was unsuccessful to avoid recurrence of life-threatening pleural chylous effusion. Ligation of the thoracic duct and apposition of an omental pedicle flap were effective in the resolution of pleural chylous leakage.



Author(s):  
Anna Kostopoulou ◽  
Epameinontas Fountas ◽  
Olga Karapanagiotou ◽  
Stamatis Kyrzopoulos

Abstract Background Inappropriate shocks have been reported in approximately 1/3 of patients with implantable cardiac defibrillators (ICDs). We report an unusual case of inappropriate ICD shocks due to atrial fibrillation (AF) caused by a missed atrial septal defect (ASD) in a patient with a modified Bentall procedure. Case summary A 67-year-old Caucasian male, with an ICD and a history of a modified Bentall procedure 24 years ago, reported to our outpatient clinic with recurrent inappropriate ICD shocks due to episodes of fast AF. The transthoracic echocardiographic exam revealed 2 large aneurysms at the ostia of the coronary arteries. We performed further evaluation with transesophageal echocardiogram (TOE) and computed tomography (CT) angiography. The aneurysms measured on CT were 3.14*2.29 cm on the right ostium and 1.9*0.99 cm on the left. A large secundum-type atrial septal defect (ASD) of 1.5 cm was revealed that was missed in all previous echocardiographic studies. The therapeutic options of surgical closure of the ASD and repair of the aneurysms or a more conservative approach with percutaneous closure of the ASD and closer follow-up were discussed with the patient. The patient declined the surgical option due to high complication risk, and closure of the ASD with an Amplatzer device was performed 3 months later. A 3 -year Follow-up was uneventful. Conclusion It is of major importance to comprehensively and thoroughly assess patients before and after a surgical intervention to not miss other treatable conditions preoperatively and complications in the postoperative period.



2021 ◽  
Vol 9 ◽  
Author(s):  
Xinya Li ◽  
Hong Zhou ◽  
Rui Zhang ◽  
Jing Zhao ◽  
Tian Li ◽  
...  

Pseudo-aneurysm is a fatal disease, and the main cause of death is massive hemorrhage secondary to the rupture of the aneurysm. This case report aims to evaluate the effects of pseudo-aneurysm excision procedure on the disease. A 4-year-old girl was readmitted on the 20th day after ventricular septal defect (VSD) closure procedure with a high fever of 40°C; aortic pseudo-aneurysm was suspected based on a spherical cystic echo (82 × 76 mm) of the ascending aorta which was detected by ultrasonic cardiogram, and the diagnosis was confirmed by an aortic computed tomograph angiography (CTA) examination and intraoperative findings. Treatment included emergency pseudo-aneurysm excision procedure and antibiotic therapy. The aortic pseudo-aneurysm was surgically removed under deep hypothermia and circulatory arrest. Antibiotics were applied according to the bacterial culture results. The pseudo-aneurysm was excised successfully, and the patient achieved a good recovery. Our case suggests that the postoperative ascending aortic pseudo-aneurysm was probably due to inappropriate purse-string suture and/or local or systematic infection, so extra precautions should be taken to avoid this life-threatening complication.



Sign in / Sign up

Export Citation Format

Share Document