Minimising microbial contamination in dental unit water systems and microbial control in dental hospitals

Author(s):  
D.C. Coleman ◽  
M.J. O’Donnell ◽  
A.S. Miller ◽  
M.A. Boyle
2018 ◽  
Vol 6 (6) ◽  
Author(s):  
Francisco Bruno Monte Gomes ◽  
Suely Torquato Ribeiro ◽  
Marcus Vinicius Freire Andrade

2011 ◽  
Vol 12 (3) ◽  
pp. 143-151 ◽  
Author(s):  
Raghunath Puttaiah ◽  
Jeff Seibert ◽  
Robert Spears

ABSTRACT Objective To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. Materials and methods This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Results Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. Conclusion In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Clinical significance Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization. How to cite this article Puttaiah R, Seibert J, Spears R. Effects of Iodine in Microbial Control of Dental Treatment Water. J Contemp Dent Pract 2011;12(3):143-151.


2018 ◽  
Vol 23 (4) ◽  
pp. 301-309 ◽  
Author(s):  
Martin Allen ◽  
Robert Clark ◽  
Joseph A. Cotruvo ◽  
Neil Grigg

The provision of a safe and sustainable drinking water supply is one of the hallmarks of a successful society. Treated drinking water entering distribution systems in virtually all U.S. public drinking water systems meets regulations and is microbiologically safe. However, the opportunity for microbial contamination from decades to century old water distribution systems is increasing with time. Thus, increased health risk to consumers should be a driving factor in accelerating reinvestment in America’s aging water distribution water systems.


2009 ◽  
Vol 107 (4) ◽  
pp. 1081-1088 ◽  
Author(s):  
R.S. Percival ◽  
D.A. Devine ◽  
B. Nattress ◽  
P. Kite ◽  
P.D. Marsh

Sign in / Sign up

Export Citation Format

Share Document