Ruling-in and Ruling-out Significant Fibrosis and Cirrhosis in Patients with Chronic Hepatitis C Using a Shear Wave Measurement Method

2017 ◽  
Vol 26 (2) ◽  
pp. 139-143 ◽  
Author(s):  
Giovanna Ferraioli ◽  
Laura Maiocchi ◽  
Raffaella Lissandrin ◽  
Carmine Tinelli ◽  
Annalisa De Silvestri ◽  
...  

Aims: To prospectively assess the cutoff values of a point shear wave measurement (SWM) method for ruling-in and ruling-out significant fibrosis and cirrhosis using transient elastography (TE) as the reference standard.Method: Consecutive patients with chronic hepatitis C were enrolled. Liver stiffness was assessed with the SWM method implemented on the HI VISION Ascendus ultrasound system (Hitachi Ltd, Japan) and with the TE method of the FibroScan® device (Echosens, France). For staging significant fibrosis (F≥2) and cirrhosis (F=4) we used the TE cutoffs of 7.0 and 12.0 kiloPascal (kPa), respectively. The diagnostic performance of SWM was assessed by calculating the area under the receiver operating characteristic (AUROC) curve. Cutoffs with specificity or sensitivity > 90% were chosen to rule-in or rule-out F≥2 and F=4.Results: 445 individuals [235 males, 210 females; mean age, 61.1 (13.3) years] were studied: 190 (42.7%) individuals had F0-F1 fibrosis stage, 82 (18.4%) F2, 46 (10.3%) F3, and 127 (28.6%) F4 fibrosis stage. For ruling-in F≥2 the SWM cutoff was 6.78 kPa [sensitivity, 76.9%(70.6-82.4); specificity, 90.3% (85.0-94.3)] and for ruling-out it was 5.55 kPa [sensitivity, 90.6% (85.8-94.1); specificity, 72.2% (64.9-78.6)]. For ruling-in F=4 the SWM cutoff was 9.15 kPa [sensitivity, 83.3% (74.4-90.2); specificity, 90.1% (86.0-93.2)] and for ruling-out it was 8.41 kPa [sensitivity, 90.6% (82.9-95.6); specificity, 82.2% (77.3-86.4)]. AUROCs were 0.92 (0.89-0.94) for F≥2 and 0.94 (0.91-0.96) for F=4.Conclusions. In clinical practice, the use of a dual cutoff of SWM may increase the confidence in staging liver fibrosis with a non-invasive shear wave elastography technique.Abbreviations: ARFI: acoustic radiation force impulse; AUROC: area under the ROC curve; CCC: concordance correlation coefficient; IQR/M: interquartile range/median; LSM: liver stiffness measurement; ROC: receiver operating characteristic; pSWE: point shear wave elastography; SWM: shear wave measurement; TE: transient elastography; US: ultrasound.

Diagnostics ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 313
Author(s):  
Rosanna Villani ◽  
Francesco Cavallone ◽  
Antonino Davide Romano ◽  
Francesco Bellanti ◽  
Gaetano Serviddio

In recent years, several non-invasive methods have been developed for staging liver fibrosis in patients with chronic hepatitis C. A 2D-Shear wave elastography (SWE) technique has been recently introduced on the EPIQ 7 US system (ElastQ), but its accuracy has not been validated in patients with chronic hepatitis C virus (HCV) infection. We enrolled 178 HCV patients to assess their liver fibrosis stage with ElastQ software using transient elastography as a reference standard. The best cut-off values to diagnose ≥ F2, ≥ F3, and F4 were 8.15, 10.31, and 12.65 KPa, respectively. Liver stiffness values had a positive correlation with transient elastography (r = 0.57; p < 0.001). The area under the receiver operating characteristics (AUROC) was 0.899 for ≥ F2 (moderate fibrosis), 0.900 for ≥ F3 (severe fibrosis), and 0.899 for cirrhosis. 2D-SWE has excellent accuracy in assessing liver fibrosis in patients with chronic hepatitis C and an excellent correlation with transient elastography.


2019 ◽  
Vol 57 (2) ◽  
pp. 85-98
Author(s):  
Romeo-Gabriel Mihăilă

Abstract Introduction. The severity of liver fibrosis can be assessed noninvasively today by liver stiffness measurements. Vibration-controlled transient elastography, shear wave elastography or magnetic resonance elastography are techniques increasingly used for this purpose. Methods. This article presents the recent advances in the use of new techniques for liver fibrosis assessment in chronic hepatitis C: the correlation between liver stiffness values and liver fibrosis estimated by liver biopsies, the prognosis role of liver stiffness values, their usefulness in monitoring the treatment response, in assessing the severity of portal hypertension and in estimating the presence of esophageal varices. Scientific articles from January 2017 to January 2018 were searched in PubMed and PubMed Central databases, using the terms “liver stiffness” and “hepatitis C”. Results. The median liver stiffness values measured with different techniques are not identical, so that FibroScan thresholds cannot be used on any other elastographic machine. The higher the liver’s stiffness measurement, the higher the liver-related events in patients with chronic hepatitis C. A liver stiffness measurement over 17 kPa could be an independent predictor for the presence of esophageal varices as well as a spleen with a longitudinal span ≥ 15 cm for patients with a value of liver stiffness < 17 kPa. A progressive and persistent decrease in liver stiffness is dependent on sustained virological response achievement. The lack of liver stiffness decrease has been associated with relapsers and a low value of liver stiffness at baseline. Conclusion. Liver stiffness provides clues about the severity and evolution of liver disease.


Diagnostics ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1817
Author(s):  
Jeong-Ju Yoo ◽  
Sang Gyune Kim ◽  
Young Seok Kim

Background: The aim of this study was to evaluate the usefulness of two different types of 2-dimensional shear wave elastography (2D-SWE) for predicting liver fibrosis stages in comparison to transient elastography (TE), using a histologic METAVIR scoring system as the reference method. Methods: A total of 203 patients with chronic liver disease were prospectively enrolled in the study. Two different 2D-SWEs (LOGIQ S8 and E9 systems, GE Healthcare, Chalfont St Giles, UK) were assessed for liver stiffness in patients with chronic liver diseases. Patients received 2D-SWE examinations with the S8 and E9 systems, and also underwent TE (FibroScan®, Echosens, France) tests and liver biopsies on the same day. Results: The most common etiology of chronic liver disease was non-alcoholic fatty liver disease (28.7%), followed by chronic hepatitis B (25.1%). Liver fibrosis stages consisted of F0 (22.6%), F1 (29.7%), F2 (16.9%), F3 (12.8%) and F4 (17.9%). Overall, S8 and E9 were well correlated with the histologic fibrosis stages. The optimal cut-off values for S8 and E9 to differentiate significant fibrosis (≥F2) were 6.70 kPa and 6.42 kPa, respectively, while the cut-off values for S8 and E9 in distinguishing liver cirrhosis were 9.15 kPa and 8.88 kPa, respectively. Among the 195 patients who had successful measurements in both S8 and E9, liver stiffness showed good inter-equipment correlation (ICC: 0.900, p < 0.001). Regarding diagnostic ability, upon comparison (FibroScan®), there were no significant differences between 2D-SWEs and TE for detecting every stage of liver fibrosis. Conclusion: In comparison to TE, 2D-SWE with LOGIQ S8 and E9 (GE Healthcare) are useful non-invasive tools for predicting significant fibrosis and liver cirrhosis.


Processes ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 753
Author(s):  
Anikó Folhoffer ◽  
Aladár D. Rónaszéki ◽  
Bettina K. Budai ◽  
Petra Borsos ◽  
Vince Orbán ◽  
...  

This study aimed to observe the effect of the direct-acting antiviral (DAA) therapy on liver stiffness (LS) and serum biomarkers. We prospectively observed 35 patients with chronic hepatitis C infection and attained a sustained virological response (SVR) after antiviral therapy. Shear wave elastography (SWE) measurement was performed at the beginning of DAA treatment and at 48 weeks after the end of treatment (EOT48w). The METAVIR score and the score for varices needing treatment (VNT) were determined based on the LS values; the fibrosis-4 (FIB4) score was calculated from laboratory tests. The baseline LS (mean ± standard deviation = 2.59 ± 0.89 m/s) decreased significantly after successful DAA therapy (1.90 ± 0.50 m/s; p < 0.001). The METAVIR score showed significant improvement at EOT48w (F0/1 = 9, F2 = 2, F3 = 10, F4 = 14) compared to the initial status (F0/1 = 2, F2 = 1, F3 = 7, F4 = 25; p < 0.028). The FIB4 score indicated less fibrosis after therapy (2.04 ± 1.12) than at baseline (3.51 ± 2.24; p < 0.018). Meanwhile, the number of patients with a high-risk of VNT was significantly less at EOT48w (4 vs. 15 at baseline; OR = 0.17 95% confidence interval (CI) = 0.05–0.59, p < 0.007). SWE indicates a significant resolution of liver fibrosis when chronic hepatitis C patients are in SVR, coinciding with a lower risk of VNT.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


2019 ◽  
Vol 49 (6) ◽  
pp. 676-686 ◽  
Author(s):  
Hiroko Iijima ◽  
Toshifumi Tada ◽  
Takashi Kumada ◽  
Natsuko Kobayashi ◽  
Masahiro Yoshida ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document