Investigation of Gap Dependency of Distortion in Output Signal from Scale Slit of Optical Encoder

2010 ◽  
Vol 130 (12) ◽  
pp. 1356-1362
Author(s):  
Hajime Nakajima ◽  
Kazuhiko Sumi ◽  
Hiroshi Inujima
Author(s):  
A.A. Barkalov ◽  
◽  
L.A. Titarenko ◽  
I.J. Zeleneva ◽  
S.S. Hrushko ◽  
...  
Keyword(s):  

2020 ◽  
Vol 8 (4) ◽  
pp. 296-307
Author(s):  
Konstantin Krestovnikov ◽  
Aleksei Erashov ◽  
Аleksandr Bykov

This paper presents development of pressure sensor array with capacitance-type unit sensors, with scalable number of cells. Different assemblies of unit pressure sensors and their arrays were considered, their characteristics and fabrication methods were investigated. The structure of primary pressure transducer (PPT) array was presented; its operating principle of array was illustrated, calculated reference ratios were derived. The interface circuit, allowing to transform the changes in the primary transducer capacitance into voltage level variations, was proposed. A prototype sensor was implemented; the dependency of output signal power from the applied force was empirically obtained. In the range under 30 N it exhibited a linear pattern. The sensitivity of the array cells to the applied pressure is in the range 134.56..160.35. The measured drift of the output signals from the array cells after 10,000 loading cycles was 1.39%. For developed prototype of the pressure sensor array, based on the experimental data, the average signal-to-noise ratio over the cells was calculated, and equaled 63.47 dB. The proposed prototype was fabricated of easily available materials. It is relatively inexpensive and requires no fine-tuning of each individual cell. Capacitance-type operation type, compared to piezoresistive one, ensures greater stability of the output signal. The scalability and adjustability of cell parameters are achieved with layered sensor structure. The pressure sensor array, presented in this paper, can be utilized in various robotic systems.


2020 ◽  
Vol 1 (2) ◽  
Author(s):  
Aditya Nugraha ◽  
Masri Bin Ardin

PVDF sensor is a sensor that is often used to measure force, strain, vibration and heat. In this study, PVDF sensors with surface polarization are used to detect cutting forces on the machine. The PVDF sensor that has been polarized on the surface is placed in the chuck part of the engine. Measuring instrumen for testing and calibrating PVDF sensors is oscilloscope with increased loading and reduced axial and tangential directions. After the calibration process, the PVDF sensor was used to measure cutting force on drilling machine, and then the results were compared with the PCB piezotronics force sensor. The PVDF sensor output signal is measured and studied for its voltage using an oscilloscope, where the output signal is compared to the weight given to the PVDF sensor. From the results of these tests indicate that the maximum deviation in axial loading is 0.32V while the tangential loading is 0.31VKeywords. PVDF sensor, Surface polarization, Drilling machine, Cutting force


Author(s):  
V. S. Bezkorovainyi ◽  
◽  
Y. V. Livсov ◽  
V. V. Yakovenko ◽  
N. A. Shatova ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3254
Author(s):  
Yuri Hayashi Isayama ◽  
Hugo Enrique Hernández-Figueroa

A generalization of the concept of multimode interference sensors is presented here for the first time, to the best of our knowledge. The existing bimodal and trimodal sensors correspond to particular cases of those interference sensors. A thorough study of the properties of the multimode waveguide section provided a deeper insight into the behavior of this class of sensors, which allowed us to establish new criteria for designing more sensitive structures. Other challenges of using high-order modes within the sensing area of the device reside in the excitation of these modes and the interpretation of the output signal. To overcome these, we developed a novel structure to excite any desired high-order mode along with the fundamental mode within the sensing section, while maintaining a fine control over the power distribution between them. A new strategy to detect and interpret the output signal is also presented in detail. Finally, we designed a high-order sensor for which numerical simulations showed a theoretical limit of detection of 1.9×10−7 RIU, making this device the most sensitive multimode interference sensor reported so far.


Sign in / Sign up

Export Citation Format

Share Document