A General Analytical Method for a Three-Phase Line-Start Permanent-Magnet Synchronous Motor

2011 ◽  
Vol 131 (5) ◽  
pp. 692-699 ◽  
Author(s):  
Kazuo Tsuboi ◽  
Tsuneo Takegami ◽  
Isao Hirotsuka ◽  
Masanori Nakamura
2013 ◽  
Vol 185 (4) ◽  
pp. 60-68 ◽  
Author(s):  
Kazuo Tsuboi ◽  
Tsuneo Takegami ◽  
Isao Hirotsuka ◽  
Masanori Nakamura

2011 ◽  
Vol 131 (12) ◽  
pp. 1465-1475 ◽  
Author(s):  
Tsuneo Takegami ◽  
Kazuo Tsuboi ◽  
Isao Hirotsuka ◽  
Masanori Nakamura

2021 ◽  
Vol 34 (4) ◽  
pp. 483-498
Author(s):  
Mahdi Karami ◽  
Norman Mariun ◽  
Kadir Ab ◽  
Radzi Mohd ◽  
Norhisam Misron

This article proposed a detection scheme for three-phase Line start permanent magnet synchronous motor (LSPMSM) under different levels of static eccentricity fault. Finite element method is used to simulate the healthy and faulty LSPMSM with different percentages of static eccentricity. An accurate laboratory test experiment is performed to evaluate the proposed index. Effects of loading condition on LSPMSM are also investigated. The fault related signatures in the stator current are identified and an effective index for LSPMSM is proposed. The simulation and experimental results indicate that the low frequency components are an effective index for detection of the static eccentricity in LSPMSM.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1583
Author(s):  
Wei-Tse Kao ◽  
Jonq-Chin Hwang ◽  
Jia-En Liu

This study aimed to develop a three-phase permanent-magnet synchronous motor drive system with improvement in current harmonics. Considering the harmonic components in the induced electromotive force of a permanent-magnet synchronous motor, the offline response of the induced electromotive force (EMF) was measured for fast Fourier analysis, the main harmonic components were obtained, and the voltage required to reduce the current harmonic components in the corresponding direct (d-axis) and quadrature (q-axis) axes was calculated. In the closed-loop control of the direct axis and quadrature axis current in the rotor reference frame, the compensation amount of the induced EMF with harmonic components was added. Compared with the online adjustment of current harmonic injection, this simplifies the control strategy. The drive system used a 32-bit digital signal processor (DSP) TMS320F28069 as the control core, the control strategies were implemented in software, and a resolver with a resolver-to-digital converter (RDC) was used for the feedback of angular position and speed. The actual measurement results of the current harmonic improvement control show that the total harmonic distortion of the three-phase current was reduced from 5.30% to 2.31%, and the electromagnetic torque ripple was reduced from 15.28% to 5.98%. The actual measurement results verify the feasibility of this method.


2021 ◽  
Vol 2083 (2) ◽  
pp. 022073
Author(s):  
Yuan Cao ◽  
Fuzhi Jing ◽  
Heng Wan

Abstract Permanent Magnet Synchronous Motor (Permanent Magnet Synchronous Motor, hereinafter referred to as PMSM) has the characteristics of small size, high efficiency, high power density and fast dynamic response, etc., and more and more applications in the transportation industry. This also has higher and higher requirements for the reliability and security of PMSM drivers. In this paper, the fault tolerant control strategy of PMSM based on three phase four switch inverter is proposed based on vector control and the simulation verification is carried out.


Sign in / Sign up

Export Citation Format

Share Document