scholarly journals Sensitivity of exhaust-air façade performance prediction to modelling approaches in IDA ICE

2019 ◽  
Vol 10 (3) ◽  
pp. 241-252
Author(s):  
A. Gelesz

Double skin façades are façade technologies that have the perspective of reducing energy use and improving comfort in buildings due to their adaptable nature. Exhaust-air façades offer the possibility to utilize solar energy by recovering heat from the façade cavity. However, the cavity overheating can be detrimental on the summer performance. Predicting performance and optimizing the system during the design phase is a challenge, especially when the cavity-air is integrated into the HVAC system. Whole-building energy simulation (BES) software tools are an adequate tool for calculating whole building performance, although these can have limitations in the accurate replication of complex building elements. The paper analyses the available and applied modelling approaches within a BES tool, and compares the outputs in terms of cavity temperature, horizontal and vertical temperature profiles, and heat flux through the façade. The sensitivity of the results on the modelling approach is evaluated. Results can serve as a guide for practitioners on the selection of the modelling approach for a given task.

Buildings ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 32
Author(s):  
Mengda Jia ◽  
Ravi Srinivasan ◽  
Robert J. Ries ◽  
Gnana Bharathy ◽  
Nathan Weyer

Occupant behaviors are one of the most dominant factors that influence building energy use. Understanding the influences from building occupants can promote the development of energy–efficient buildings. This paper quantifies the impact of different occupant behavior information on building energy model (BEM) from multiple perspectives. For this purpose, an occupant behavior model that uses agent–based modeling (ABM) approach is implemented via co-simulation with a BEM of an existing commercial building. Then, actual occupant behavior data in correspondence to ABM output, including operations on window, door, and blinds in selected thermal zones of the building are recorded using survey logs. A simulation experiment is conducted by creating three BEMs with constant, actual, and modeled occupant behavioral inputs. The analysis of the simulation results among these scenarios helps us gain an in–depth understanding of how occupant behaviors influence building performance. This study aims to facilitate robust building design and operation with human–in–the–loop system optimization.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 749
Author(s):  
John H. Scofield ◽  
Susannah Brodnitz ◽  
Jakob Cornell ◽  
Tian Liang ◽  
Thomas Scofield

In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.