AC Loss Characteristics of Stacks of YBCO Coated Conductors

2006 ◽  
Vol 946 ◽  
Author(s):  
Francesco Grilli ◽  
Stephen P. Ashworth ◽  
Svetlomir Stavrev

ABSTRACTPractical applications of YBCO coated conductors (CC) involving superconducting coils will utilize tapes packed together in an arrangement resembling a vertical stack. In such configuration there is an important electromagnetic interaction between the tapes, which strongly influences the loss characteristic of the device.In the presence of an external magnetic field, the losses are reduced compared to an isolated tape because of the reduced aspect ratio of the conductor and, at least for low fields, because of an effective screening of the central part of the stack. On the contrary, in the case of AC transport current, the losses tend to increase due to the enhancement of the local field caused by the interaction of the self-field produced by neighboring tapes. In practical situations the conductor is usually subjected to both transport current and magnetic field, so that there is a trade-off between the two effects.In this paper we investigate, both experimentally and by means of finite-element method calculations, the ac loss behavior of a stack composed by a finite number of tapes in different working conditions, and we compare the AC losses to the ones of non-interacting tapes in order to determine if the use of stacked tapes is advantageous from the point of view of power dissipation.

2013 ◽  
Vol 23 (3) ◽  
pp. 4300704-4300704 ◽  
Author(s):  
Andrew Gavrilin ◽  
Jun Lu ◽  
Hongyu Bai ◽  
David Hilton ◽  
W Markiewicz ◽  
...  

A 17 T high-temperature superconducting two-coil magnet (insert) to be operated in a 15 T low-temperature superconducting multisection magnet (outsert) is the most demanding part of the National High Magnetic Field Laboratory all-superconducting 32 T magnet system. The HTS coils are of the pancake type and to be wound with REBCO coated conductors/tapes manufactured by SuperPower, Inc. The distribution of AC losses in the HTS windings during the magnet charging/discharging process are computed and analyzed with due regard for the AC loss density dependence on the magnetic field and the field angle. The calculations are based on the measured magnetization of a representative sample against magnetic field and field angle. The results enable determination of heat load on the magnet and its cryogenic system. Since the magnet is of the pool-cooled type, a related helium vapor bubble problem can develop owing to the high field and field gradients, and the diamagnetic susceptibility of helium.


2007 ◽  
Vol 1001 ◽  
Author(s):  
Francesco Grilli ◽  
Stephen P. Ashworth

AbstractCertain practical applications of YBCO coated conductors (CC) involve superconducting tapes wound in coils. In such a configuration the superconducting tape is arranged as closely packed turns, leading to an increase of the magnetic field generated by the current in the tapes and, consequently, a significant increase in the AC losses, with respect to an ‘isolated’ tape. In order to predict and reduce the refrigeration requirements of applications, it is therefore very important to be able to quantify the magnitude of such AC losses, both experimentally and by means of numerical calculations.


2006 ◽  
Vol 47 ◽  
pp. 195-203 ◽  
Author(s):  
Pascal Tixador

After the emergence of AC NbTi strands, superconducting transformers were successfully built. But the very high cost of 4 K cryogenics made these transformers economically not attractive. The high Tc superconductors (HTS), operating at much higher temperatures, change these conclusions with low cost HTS conductors. The high cost of PIT tapes and the relatively large AC losses remain issues. The second generation HTS wires, the REBCO coated conductors, are under development and achieved substantial progress recently. They operate at higher temperatures and intrinsically show lower AC losses especially for transformers. MgB2 is the third option. The magnetic flux density conditions make possible the operation at 27 K and they show low costs. This paper provides a preliminary design for an on-board 40 MVA transformer using YBCO coated conductors and MgB2 wires. Both superconducting transformers show similar volume and weight. The power density per unit mass and volume is improved by a factor about two, cryogenic included, compared to resistive systems. This makes them very attractive for on-board mobile systems. The economical point of view will be discussed based on some targets price/performance for superconductors and cryocoolers. MgB2 is penalized by its operation at lower temperature (27 K / 77 K), which makes cryogenics very expensive. The advantage of the low cost of MgB2 compared to REBCO may be lost except with very low AC loss MgB2 tapes.


2021 ◽  
Vol 11 (6) ◽  
pp. 2741
Author(s):  
Sergey Zanegin ◽  
Nikolay Ivanov ◽  
Vasily Zubko ◽  
Konstantin Kovalev ◽  
Ivan Shishov ◽  
...  

The article is devoted to the study of losses in devices based on high-temperature superconductors of the 2nd generation. The complexity of the devices under study increases from a single rack coil to a winding assembled from several coils, and finally to an electric machine operating in generator mode. This is the way to experimentally study the behavior of 2nd generation high temperature superconductor (2G HTS) carrying a transport current in various conditions: self-field, external DC, and AC magnetic field. Attention is also paid to the losses in the winding during its operation from the inverter, which simulates the operating conditions in the motor mode of a propulsion system.


1995 ◽  
Vol 5 (2) ◽  
pp. 709-712 ◽  
Author(s):  
M. Ciszek ◽  
B.A. Glowacki ◽  
S.P. Ashworth ◽  
A.M. Campbell ◽  
J.E. Evetts

Author(s):  
Jianfeng Huang ◽  
Y. Ilyin ◽  
W.A.J. Wessel ◽  
Ruben Lubkemann ◽  
Erik Krooshoop ◽  
...  

Abstract The inter-strand contact resistance and AC losses were measured on an ITER PF Coil joint in a parallel applied AC magnetic field. In addition, the hysteresis loss was measured as a function of the angle with the applied magnetic field on a NbTi strand of the same type as in the joint with a Vibrating Sample Magnetometer (VSM). The AC loss measurements were performed at four applied field conditions for combinations of 0 or 1 T offset field and 0.2 or 0.4 T sinusoidal amplitude. The hysteresis loss of the joint was compared with the measured AC loss density of the NbTi strand for the same field conditions as the joint AC loss measurement but with varying the angle of the applied field. The subsequent cable twist angles affect the hysteresis loss since the critical current and penetration field depend on the angle of the applied field. It is found that 15.5° is an effective angle for the calculation of the hysteresis loss of joint when compared to the single strand measurement. The inter-strand contact resistance measurements cover all the typical strand combinations from the five cabling stages of the individual conductors, as well as the strand combinations across the two conductors to characterize the inter-strand including the copper sole resistivity. It’s the first time to measure the contact resistances and AC losses of the full-size ITER PF joint. By comparing the measured and simulated data in the JackPot-ACDC model, it’s also the first time to obtain the accurate inter-strand, inter-petal and strand to copper sole contact resistivities, which are the main input parameters for the further quantitative numerical analysis of the PF joints, in any current and magnetic field conditions.