Process Monitoring for Fabrication of Mercuric Iodide Room Temperature Radiation Detectors

1993 ◽  
Vol 324 ◽  
Author(s):  
J. M. Van Scyoc ◽  
T. E. Schlesinger ◽  
H. Yao ◽  
R. B. James ◽  
M. Natarajan ◽  
...  

AbstractIn the fabrication of mercuric iodide room temperature radiation detectors, as in any semiconductor process, the quality of the final device can be very sensitive to the details of the processing steps. Each processing step can either reduce the intrinsic defects and those extrinsic defects introduced by earlier steps, or it can introduce new defects. In mercuric iodide these defects can act as trapping and recombination centers, thereby degrading immediate device performance or leading to long-term reliability problems. With careful study and monitoring of each step, the process can be modified to improve the end product. In this work we used several techniques to study processing steps and their effects. Photoluminescence spectroscopy and photoionization revealed defects introduced during processing. One critical step is the formation of electrical contacts, as both the material choice and deposition method have an impact. Four point probe sheet resistance methods were used to characterize the loss of material from the contact as it reacted with or moved into the bulk semiconductor. Ellipsometry was used to characterize the intrinsic optical functions of the material, and to study the effects of surface aging on these functions. Results from this work provide suggestions for the modification and monitoring of the detector fabrication process.

1993 ◽  
Vol 302 ◽  
Author(s):  
A. Y. Cheng

ABSTRACTMercuric iodide detectors are leading candidates for room-temperature radiation detection applications. The inherently reactive nature of mercuric iodide limits the number of materials suitable for fabrication of electrical contacts. The theoretical stabilities of elemental contact materials on mercuric iodide were evaluated at 25°C. Additionally, the stabilities of transparent conductive compounds, for photodetector applications, were studied. Calculations were based on Gibbs free energy data, estimates and a series of hypothesized reactions with mercuric iodide. Leading candidate materials were identified and compared to experimental results.


1995 ◽  
Vol 378 ◽  
Author(s):  
J. M. Van Scyoc ◽  
R. B. James ◽  
T. E. Schlesinger ◽  
T. S. Gilbert

AbstractIn the fabrication of mercuric iodide (HgI2) room temperature radiation detectors, as in any semiconductor process, the quality of the final device is very sensitive to the impurities and defects present. Each process step can change the effects of existing defects, reduce the number of defects, or introduce new defects. In HgI2 detectors these defects act as trapping and recombination centers, thereby degrading immediate performance and leading to unstable devices. In this work we characterized some of the defects believed to strongly affect detector operation. Specifically, we studied impurities that are known to be present in typical HgI2 materials. Leakage current measurements were used to study the introduction and characteristics of these impurities, as such experiments reveal the mobile nature of these defects. In particular, we found that copper, which acts as a hole trap, introduces a positively charged center that diffuses and drifts readily in typical device environments. These measurements suggest that Cu, and related impurities like silver, may be one of the leading causes of HgI2 detector failures.


2021 ◽  
Vol 119 (6) ◽  
pp. 062103
Author(s):  
A. Brovko ◽  
P. Rusian ◽  
L. Chernyak ◽  
A. Ruzin

2020 ◽  
Vol 116 (16) ◽  
pp. 162107 ◽  
Author(s):  
Sandeep K. Chaudhuri ◽  
Mohsin Sajjad ◽  
Krishna C. Mandal

1982 ◽  
Vol 16 ◽  
Author(s):  
John H. Howes ◽  
John Watling

ABSTRACTThis paper describes the fabrication of mercuric iodide nuclear radiation detectors suitable for X and gamma ray spectrometry at room temperature. The active area of the detectors studied are between 0.2 and 1.5cm sq and they are up to 0.5mm thick. The method of producing a stable electrical contact to the crystal using sputtered germanium has been studied. The X-ray resolution of a 1.5cm sq. area detector at 32 keV is 2.3 keV FWHM when operated at room temperature in conjunction with a time variant filter amplifier. A factor which is important in the fabrication of the detector is the surface passivation necessary to achieve a useful detector life.This type of detector has been used on a wavelength dispersive X-ray spectrometer for energy measurements between 10 and 100 keV. The advantages over the scintillation counter, more commonly used, is the improved resolution of the HgI2 detector and its smaller size. The analyser is primarily used for the detection of low levels of heavy metals on particulate filters. The detectors have also been used on an experimental basis for gamma ray backscatter measurements in the medical field.


2012 ◽  
Vol 41 (10) ◽  
pp. 2912-2916 ◽  
Author(s):  
G. Yang ◽  
A.E. Bolotnikov ◽  
P.M. Fochuk ◽  
Y. Cui ◽  
G. S. Camarda ◽  
...  