scholarly journals Post-growth Annealing of Cadmium Zinc Telluride Crystals for Room-Temperature Radiation Detectors

2012 ◽  
Vol 41 (10) ◽  
pp. 2912-2916 ◽  
Author(s):  
G. Yang ◽  
A.E. Bolotnikov ◽  
P.M. Fochuk ◽  
Y. Cui ◽  
G. S. Camarda ◽  
...  
CrystEngComm ◽  
2022 ◽  
Author(s):  
Wanzhong Li ◽  
Jian Sun ◽  
Chong Deng

Cadmium Zinc Telluride (CdZnTe) single crystals have been widely ultilized in various photoelectron devices such as radiation detectors and solar cells. Different types of ordered phases have also been investigated...


2020 ◽  
Vol 27 (2) ◽  
pp. 319-328 ◽  
Author(s):  
Leonardo Abbene ◽  
Fabio Principato ◽  
Gaetano Gerardi ◽  
Antonino Buttacavoli ◽  
Donato Cascio ◽  
...  

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation of the charge losses at the inter-pixel gap region. High-rate measurements demonstrated the absence of high-flux radiation-induced polarization phenomena up to 2 × 106 photons mm−2 s−1. These activities are in the framework of an international collaboration on the development of energy-resolved photon-counting systems for high-flux energy-resolved X-ray imaging.


2020 ◽  
Vol 27 (6) ◽  
pp. 1564-1576
Author(s):  
Leonardo Abbene ◽  
Gaetano Gerardi ◽  
Fabio Principato ◽  
Antonino Buttacavoli ◽  
Saverio Altieri ◽  
...  

In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis was performed on a wide range of collected and induced charge pulse shapes using custom 32-channel digital readout electronics. Excellent room-temperature energy resolution (1.3% FWHM at 662 keV) was achieved using the detectors without any spectral corrections. Further improvements (0.8% FWHM at 662 keV) were also obtained through a novel correction technique based on the analysis of collected-induced charge pulses from anode and drift strips. These activities are in the framework of two Italian research projects on the development of spectroscopic gamma-ray imagers (10–1000 keV) for astrophysical and medical applications.


2000 ◽  
Vol 29 (6) ◽  
pp. 708-712 ◽  
Author(s):  
Kaushik Chattopadhyay ◽  
Miguel Hayes ◽  
Jean-Olivier Ndap ◽  
Arnold Burger ◽  
W. J. Lu ◽  
...  

2009 ◽  
Vol 105 (11) ◽  
pp. 114910 ◽  
Author(s):  
S. A. Awadalla ◽  
H. Chen ◽  
J. Mackenzie ◽  
P. Lu ◽  
K. Iniewski ◽  
...  

1999 ◽  
Author(s):  
B. A. Brunett ◽  
J. C. Lund ◽  
J. M. Van Scyoc ◽  
N. R. Hilton ◽  
E. Y. Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document