Assessment of the effects of staining solutions, carbamide peroxide, and mouthwashes on color stability of composite resin

2014 ◽  
Vol 1 (2) ◽  
pp. 36-41
Author(s):  
Erica Crastechini ◽  
Paula de Siqueira Barbosa ◽  
Heleine Maria Chagas Rego ◽  
Priscila Holleben ◽  
Carlos Rocha Gomes Torres ◽  
...  
2014 ◽  
Vol 20 (4) ◽  
pp. 1234-1239 ◽  
Author(s):  
Ana Luísa Botta Martins de Oliveira ◽  
Ana Carolina Botta ◽  
Juliana Álvares Duarte Bonini Campos ◽  
Patrícia Petromilli Nordi Sasso Garcia

AbstractThis study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro–Wilk test (p>0.05 for the different immersion media) and Sidak’s test (p<0.05 for the differences between groups). In the interaction between the repolishing and the immersion media, Fluorgard showed a statistical difference between the ∆E values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.


2011 ◽  
Vol 105 (4) ◽  
pp. 236-241 ◽  
Author(s):  
Anderson Catelan ◽  
André Luiz Fraga Briso ◽  
Renato Hermann Sundfeld ◽  
Marcelo Coelho Goiato ◽  
Paulo Henrique dos Santos

2021 ◽  
Vol 6 (1) ◽  
pp. 85
Author(s):  
Rahmi Khairani Aulia

ABSTRACT:Composite resins are currently the most popular restorative material in dentistry. This is due to good aesthetics and maximum conservation ability. Behind these advantages, there are disbenefits of composite resin materials, such as polymerization shrinkage, which can lead to restoration failure. Various attempts have been investigated to reduce the shrinkage incidence of composite resins, one of which is the technique of placing the restorative material into the cavity. The restoration filling technique is recognized as a significant factor in shrinkage stress. By using a special filling technique, the polymerization shrinkage damage stress can be reduced. There are several techniques in performing composite resin fillings, including bulk and incremental techniques. These techniques have their respective advantages and disadvantages. The aim of this literature review was to compare the physical properties of composite resin restorations with bulk filling and incremental techniques. Physical properties that being studied include polymerization shrinkage, stress shrinkage, degree of conversion, bonding strength, water resorption, color stability, and temperature increase. Comparing the two techniques, composite resin with incremental filling technique has superior physical properties compared to bulk technique. From the comparison of the two techniques, the composite resin with incremental filling technique has superior physical properties compared to the bulk technique, especially in higher conversion which causes lower shrinkage stress. This situation makes the incremental technique provide better bond strength, water resorption, color stability, and lower temperature rise.Keywords: Bulk, Composite Resin, Incremental,  Physical Properties, Restoration, Restoration Technique


2013 ◽  
Vol 07 (02) ◽  
pp. 165-171 ◽  
Author(s):  
Duygu Tuncer ◽  
Emel Karaman ◽  
Esra Firat

ABSTRACT Objective: To investigate the effect of beverages′ temperature on the surface roughness, hardness, and color stability of a composite resin. Materials and Methods: Fifty specimens of the Filtek Z250 composite (3M ESPE, Dental Products, St.Paul, MN, USA) were prepared and initial roughness, microhardness, and color were measured. Then the specimens were randomly divided into five groups of 10 specimens each: Coffee at 70°C, coffee at 37°C, cola at 10°C, cola at 37°C, and artificial saliva (control). After the samples were subjected to 15 min × 3 cycles per day of exposure to the solutions for 30 days, the final measurements were recorded. Results: After immersion in beverages, the artificial saliva group showed hardness values higher than those of the other groups (P < 0.001) and the microhardness values were significantly different from the initial values in all groups except for the control group. Both cola groups showed roughness values higher than the baseline values (P < 0.05), while the other groups showed values similar to the baseline measurements. When ΔE measurements were examined, the 70°C coffee group showed the highest color change among all the groups (P < 0.05). Conclusion: High-temperature solutions caused alterations in certain properties of composites, such as increased color change, although they did not affect the hardness or roughness of the composite resin material tested.


2011 ◽  
Vol 22 (5) ◽  
pp. 365-368 ◽  
Author(s):  
Fernanda Valentini ◽  
Simone Gomes Dias de Oliveira ◽  
Guilherme Zdradk Guimarães ◽  
Renata Pereira de Sousa Barbosa ◽  
Rafael Ratto de Moraes

This study investigated the effect of sealant application on the color stability of composite resin restorations. Cavities in bovine incisors were restored with composite resin (Opallis; FGM) and the teeth were assigned to 4 groups (n=10). A sealant (Fill Glaze; Vigodent) was applied over the restorations of 2 groups. Baseline color measurements based on the CIEL*a*b* system were carried out using a spectrophotometer. Half the number of specimens was immersed in distilled water, and half was immersed in coffee 4 h/day. Color measurements were repeated after 1 h, 24 h, 7 days and 3 months. Data for each immersion solution were separately subjected to a two-way repeated measures ANOVA and Tukey’s test (α=0.05). For the group without sealant immersed in water, no significant differences were observed among the periods (p≥0.138), but the color was different compared with baseline (p<0.001). For the group with sealant application, the periods baseline, 1 h and 3 months presented similar results (p≥0.924). For groups immersed in coffee, when the sealant was not used, no significant differences were detected between the baseline and the periods 1 h and 24 h (p≥0.499), but the color changed significantly thereafter (p≤0.003). In the group with sealant, significant differences were detected for all periods compared with each other (p<0.001). In conclusion, application of sealant dramatically increased the staining of the restorations exposed to coffee.


2020 ◽  
Vol Volume 12 ◽  
pp. 423-428
Author(s):  
Akshata Patil ◽  
Vidya-Saraswathi Muliya ◽  
Kalyana-Chakravarthy Pentapati ◽  
Shobha Kamath

2014 ◽  
Vol 30 ◽  
pp. e67
Author(s):  
C.G. Savi ◽  
V.C. Ruschel ◽  
H.P. Maia ◽  
R.C. De Ré Silveira ◽  
C.P. Gré ◽  
...  

2012 ◽  
Vol 13 (1) ◽  
pp. 16-22 ◽  
Author(s):  
Soodabeh Kimyai ◽  
Siavash Savadi Oskoee ◽  
Amir Ahmad Ajami ◽  
Mahmoud Bahari ◽  
Mehdi Abed Kahnamoui ◽  
...  

ABSTRACT Aim The aim was to evaluate the effects of Oral-B (OB), Listerine (LN) and Rembrandt Plus (RM) mouthrinses on microleakage of composite resin restorations bonded with two adhesive systems after bleaching with 10% carbamide peroxide. Materials and methods A total of 60 Cl V cavities were prepared on human premolars. The occlusal and gingival margins were placed 1 mm occlusal to and apical to CEJ respectively. The teeth were randomly divided into two groups based on the adhesive system used: Excite (EX) and Clearfil SE Bond (CSE) groups. After composite resin restoration of cavities, thermocycling and bleaching with 10% carbamide peroxide for 2 hours daily for 14 days, the teeth in each adhesive group were further subdivided into three subgroups and were immersed for 12 hours in the three OB, RM and LN mouthrinses. The teeth were then placed in 2% basic fuschin for 24 hours. After dissecting the teeth, microleakage was evaluated under a stereomicroscope at 16×. Data was analyzed with multifactor ANOVA and Bonferroni test at p < 0.05. Results Microleakage with EX was significantly higher than that with CSE (p = 0.009). Microleakage at gingival margins was significantly higher than that at occlusal margins (p = 0.15). Microleakage with OB was higher than that with LN (p = 0.02). However, there were no significant differences in microleakage between LN and RM (p = 1) and between RM and OB (p = 0.15). In addition, with the EX adhesive system, microleakage with OB was higher than that with LN and RM (p = 0.02). Conclusion In the present study, microleakage of composite resin restorations was influenced by the type of the adhesive system, mouthrinse type and the location of the cavity margin. Clinical significance Use of some mouthrinses, such as OB after bleaching can increase postrestoration microleakage of resin composite restorations bonded with etch-and-rinse adhesive systems. How to cite this article Ajami AA, Bahari M, Oskoee SS, Kimyai S, Kahnamoui MA, Rikhtegaran S, Ghaffarian R. Effect of Three Different Mouthrinses on Microleakage of Composite Resin Restorations with Two Adhesive Systems after Bleaching with 10% Carbamide Peroxide. J Contemp Dent Pract 2012;13(1):16-22.


Sign in / Sign up

Export Citation Format

Share Document