scholarly journals Choice of tracers for the evaluation of spray deposits

2005 ◽  
Vol 62 (5) ◽  
pp. 440-445 ◽  
Author(s):  
Luiz Antonio Palladini ◽  
Carlos Gilberto Raetano ◽  
Edivaldo Domingues Velini

Tracer substances, used to evaluate spraying effectiveness, ordinarily modify the surface tension of aqueous solutions. This study aimed to establish a method of using tracers to evaluate distribution and amount of spray deposits, adjusted to the surface tension of the spraying solution. The following products were tested: 0.15% Brilliant Blue, 0.15% Saturn Yellow in 0.015% Vixilperse lignosulfonate, and 0.005% sodium fluorescein, and mixtures of Brilliant Blue plus Saturn Yellow and Brilliant Blue plus sodium fluorescein at the same concentrations. Solutions were deposited on citrus leaves and stability was determined by measuring fluorescence and optical density of solutions without drying, dried in the dark and exposed to sunlight for 2, 4 and 8 h. These values were compared to those obtained directly in water. The static surface tension of the tracer solution was determined by weighing droplets formed during a period of 20 to 40 seconds. The Brilliant Blue and Saturn Yellow mixture at 0.15% was stable under all conditions tested. It was not absorbed by the leaves and maintained the same surface tension as that of water, thus permitting concentration adjustment to the same levels used for agrochemical products, and allowing the development of a qualitative method based on visual evaluation of the distribution of the pigment under ultraviolet light and of a quantitative method based on the determination of the amount of the dye deposited in the same solution. Spray deposition could be evaluated at different surface tensions of the spraying solution, simulating the effect of agrochemical formulations.

2013 ◽  
Vol 18 (2-3) ◽  
pp. 33-41
Author(s):  
Dominik Sankowski ◽  
Marcin Bakala ◽  
Rafał Wojciechowski

Abstract The good quality of several manufactured components frequently depends on solidliquid interactions existing during processing. Nowadays, the research in material engineering focuses also on modern, automatic measurement methods of joining process properties, i.a. wetting force and surface tension, which allows for quantitative determination of above mentioned parameters. In the paper, the brazes’ dynamic properties in high-temperatures’ measurement methodology and the stand for automatic determination of braze’s properties, constructed and implmented within the research grant nr KBN N N519 441 839 - An integrated platform for automatic measurement of wettability and surface tension of solders at high temperatures, are widely described


1989 ◽  
Vol 35 (10) ◽  
pp. 2127-2129 ◽  
Author(s):  
Y Bergqvist ◽  
L Karlsson ◽  
L Fohlin

Abstract This simple method of centrifugal analysis for total protein in human breast milk is based on the change in the wavelength of the absorbance maximum of Coomassie Brilliant Blue G-250 when the dye is bound to protein. Within-run and between-day CVs were 3.8% and 4.8%, respectively. Compared with a micro-Kjeldahl method for determination of total nitrogen, the coefficient of correlation was 0.99.


Sign in / Sign up

Export Citation Format

Share Document