Design procedures for high-strength concrete cross-sections

2009 ◽  
Vol 10 (3) ◽  
pp. 109-116
Author(s):  
L. da Conceição Domingues Shehata ◽  
A. Lopes de Paula ◽  
I. Abd El Malik Shehata
2019 ◽  
Vol 945 ◽  
pp. 80-84
Author(s):  
O.E. Sysoev ◽  
A.Y. Dobryshkin ◽  
Ye.O. Sysoyev

The article is devoted to the investigation of pipe-concrete prestressed structural elements with high efficiency. This is due to a more complete use of the strength properties of structural materials in the pipe-concrete beam. The article presents various methods for calculating pipe-concrete elements. The design of a concrete tube with a prestressed element using high-strength concrete is presented. The results of calculations of various designs are shown and the cross-sections of beams for perception of the same bending load are selected. A comparison is made between the consumption of beam materials of various designs. The effectiveness of the use of pipe-concrete elements for receiving bending loads made of high-strength concrete with prestressed reinforcement is shown in comparison with the construction of beams of traditional high-strength concrete, high-strength concrete pipe-concrete with no prestressing of reinforcement and metal beam, mass of the element, consumption of metal and concrete.


2014 ◽  
Vol 501-504 ◽  
pp. 963-968
Author(s):  
Thomas Vincent ◽  
Togay Ozbakkaloglu

This paper presents an experimental investigation on the influence of specimen slenderness on axial compressive behavior of concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs). A total of 18 aramid FRP- (AFRP) confined high-strength concrete (HSC) specimens with circular cross-sections were tested. Specimens with height-to-diameter ratios of 1, 2, 3 and 5 were manufactured and tested, with all specimens maintaining a nominal diameter of 150 mm. The results indicate that specimens with an H/D of 1 exhibit significantly higher strength and strain enhancements compared to specimens with H/D ratios of 2 to 5. The influence of slenderness on specimens with H/D ratios between 2 and 5 was found to be significant in regards to axial strain enhancement, with a decrease observed as specimen slenderness increased. On the other hand, the influence of slenderness on axial strength enhancement of specimens with H/D ratios between 2 and 5 was found to be negligible.


2015 ◽  
Vol 744-746 ◽  
pp. 173-178
Author(s):  
Thomas Vincent

This paper presents an experimental investigation on the influence of prestress on axial compressive behavior of concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs). A total of 12 aramid FRP- (AFRP) confined high-strength concrete (HSC) specimens with circular cross-sections were tested under monotonic axial compression. All specimens were cylinders with 152 mm diameter and 305 mm height and their unconfined concrete strengths were approximately 100 to 110 MPa. The influence of FRP prestress was examined by applying 3 different levels of lateral prestress ranging from 4.29 to 7.27 MPa. In addition to the prestressed specimens, companion specimens with no applied prestress were manufactured and tested to establish reference values. Results of the experimental study indicate that the influence of prestress on compressive strength is significant, with an increase in ultimate strength observed in all prestressed specimens compared to that of non-prestressed specimens. On the other hand, the influence of prestress on axial strain was found to be minimal, with prestressed specimens displaying a slight decrease in ultimate strain, compared to their non-prestressed counterparts. The results also indicate that prestressing the AFRP shell prevents the sudden drop in strength, typically observed in FRP-confined HSC specimens, that initiates at the transition point which connects the first and second branches of the stress-strain curves.


2014 ◽  
Vol 919-921 ◽  
pp. 23-28 ◽  
Author(s):  
Thomas Vincent ◽  
Togay Ozbakkloglu

This paper presents an experimental investigation into the axial strain measurement method of fiber reinforced polymer (FRP)-confined normal-and high-strength concrete (NSC and HSC). A total of 15 FRP-confined concrete specimens with circular cross-sections were tested under monotonic axial compression. Axial strain recordings were compared on specimens instrumented with three different measurement methods: axial strain gauges and full-and mid-height linear variable displacement transformers (LVDTs). The ultimate conditions are tabulated for each measurement method and key experimental outcomes discussed. The results indicate that axial strains of FRP-confined HSC are highly sensitive to the instrumentation arrangement and significant differences occur in the results obtained from different measurement methods.


2012 ◽  
Vol 2 (3) ◽  
pp. 102-104 ◽  
Author(s):  
Suthar Sunil B ◽  
◽  
Dr. (Smt.) B. K. Shah Dr. (Smt.) B. K. Shah

PCI Journal ◽  
1984 ◽  
Vol 29 (3) ◽  
pp. 44-73 ◽  
Author(s):  
Harold J. Jobse ◽  
Saad E. Moustafa

Sign in / Sign up

Export Citation Format

Share Document