scholarly journals Cardiac Contractility Modulation Device and Subcutaneous Implantable Cardioverter Defibrillator Combination: A New Hope for Heart Failure Patients with Low Ejection Fraction and Narrow QRS Complex

Author(s):  
B Al-Ghamdi
2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Agostino Mattera ◽  
Vincenzo Coscia ◽  
Marcello Brignoli ◽  
Angela Fusco ◽  
Claudia Concilio ◽  
...  

Abstract Aims Cardiac amyloidosis (CA) is primarily associated with fibril deposits in many cardiac structures, causing biventricular wall thickness and stiffness. CA may result in arrhythmias and particularly in an aggressive form of heart failure (HF). Cardiac contractility modulation (CCM) showed to be a concrete therapeutic option in patients with symptomatic HF despite optimal medical therapy (OMT), with Left Ventricular Ejection Fraction (LVEF) between 25% and 45%, with narrow QRS complex (<130 ms). This case aims to further explore the effectiveness of CCM therapy in a patient affected by concomitant ischaemic cardiomyopathy and CA. Methods and results A 42-year-old man with Chronic HF secondary to both post-ischaemic due to spontaneous coronary artery dissection (SCAD) and post alcoholic dilated cardiomyopathy was hospitalized at our department in February 2020 due to worsening HF (3rd HF hospitalization in the same year). The patient was a NYHA class III, with chronic kidney failure, a narrow QRS complex (100 ms) and a LVEF of 27% with familiar history of sudden death, already implanted with ICD. The patient resulted untreatable with sacubitril/valsartan, as it elicited strong hypotension. During current hospitalization the BNP value was 942.60 pg/ml, and the Quality of Life (QoL) evaluated from Minnesota Living with Heart Failure Questionnaire (MLHFQ) score was 72 points. Moreover, the patient underwent umbilical biopsy that confirmed the presence of amyloidosis. Thus, the CCM therapy device (Optimizer® Smart, Impulse Dynamics) was implanted to try to reduce HF symptoms and hospitalizations. The therapy was programmed for 10 h per day, with delivery of CCM from both septal leads with amplitude of 6.5 V at 20.56 ms pulses duration. Figure 1A and B shows the septal position of leads and a surface ECG with the CCM therapy spike after QRS. The patient significantly improved as early as the first period after implantation. The 10-month in-office FU performed on December 2020 revealed in addition to the absence of new HF hospitalizations, a significant improvement in QoL and HF-symptoms, with a MLWHFQ score of 42, an enhancement to NHYA class II, and even a slight decrease of BNP of 767 pg/ml. The echo exam revealed no significant changes in the EF, with an improvement of global longitudinal strain and no worsening of other haemodynamic parameters. A further FU performed in June 2021 showed continuous improvement of QoL with a MLWHFQ score of 25 e no HF hospitalizations. Conclusions In this patient affected by multiple cardiomyopathies, including CA, CCM therapy proved to improve its QoL with no HF hospital admissions since the implantation. The absence of significant echocardiographic worsening is a positive aspect, considering the patient’s status, the concomitant aetiologies, and the presence of amyloidosis, given its progressive and infiltrative nature.


2021 ◽  
Vol 11 (1) ◽  
pp. 121
Author(s):  
Marco Canepa ◽  
Pietro Palmisano ◽  
Gabriele Dell’Era ◽  
Matteo Ziacchi ◽  
Ernesto Ammendola ◽  
...  

The role of prognostic risk scores in predicting the competing risk of non-sudden death in heart failure patients with reduced ejection fraction (HFrEF) receiving an implantable cardioverter-defibrillator (ICD) is unclear. To this goal, we evaluated the accuracy and usefulness of the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score. The present analysis included 1089 HFrEF ICD recipients enrolled in the OBSERVO-ICD registry (NCT02735811). During a median follow-up of 36 months (1st–3rd IQR 25–48 months), 193 patients (17.7%) experienced at least one appropriate ICD therapy, and 133 patients died (12.2%) without experiencing any ICD therapy. The frequency of patients receiving ICD therapies was stable around 17–19% across increasing tertiles of 3-year MAGGIC probability of death, whereas non-sudden mortality increased (6.4% to 9.8% to 20.8%, p < 0.0001). Accuracy of MAGGIC score was 0.60 (95% CI, 0.56–0.64) for the overall outcome, 0.53 (95% CI, 0.49–0.57) for ICD therapies and 0.65 (95% CI, 0.60–0.70) for non-sudden death. In patients with higher 3-year MAGGIC probability of death, the increase in the competing risk of non-sudden death during follow-up was greater than that of receiving an appropriate ICD therapy. Results were unaffected when analysis was limited to ICD shocks only. The MAGGIC risk score proved accurate and useful in predicting the competing risk of non-sudden death in HFrEF ICD recipients. Estimation of mortality risk should be taken into greater consideration at the time of ICD implantation.


Sign in / Sign up

Export Citation Format

Share Document