scholarly journals Worst Case Error Budget and Analysis in the Design of a Novel Signal Conditioning Circuit for Eddy Current Flow Meter in Sodium Cooled Fast Breeder Reactor

2013 ◽  
Vol 6 (11) ◽  
pp. 1-7
Author(s):  
Poornapushpakala Suriyamoorthi

Author(s):  
Ismael Payo ◽  
J. L. Polo ◽  
Blanca Lopez ◽  
Diana Serrano ◽  
Antonio M. Rodríguez ◽  
...  

Abstract Conductive Hydrogels are soft materials which have been used by some researchers as resistive strain sensors in the last years. The electrical resistance change, when the sensor is stretched or compressed, is usually measured by the two-electrode method. This method is not always suitable to measure the electrical resistance of polymers-based materials, like hydrogels, because it could be highly influenced by the electrode/sample interface, as explained in this study. For this reason, a signal conditioning circuit, based on four-electrode impedance measurements, is proposed to measure the electrical resistance change when the gel is stretched or compressed. Experimental results show that the tested gels can be used as resistance force/pressure sensors with a quite linear behaviour.



2021 ◽  
Author(s):  
ARUN K ◽  
LEKSHMI M S ◽  
SUJA K J

Abstract Metal oxide semiconductors have been widely used in the eld of gas sensor study. Various researches are being done to improve the sensitivity of the sensing material for applications like breath analyzers. In this work, a theoretical investigation and analysis of the n- type metal oxide for Acetone gas detection are carried out. The rate of change of resistance of the sensing material with respect to the change in the concentration of the target gas is analyzed. Acetone being a reducing gas the resistance was found to decrease for n-type material. The simulations were done using COMSOL Multiphysics and results showed that the resistance of the sensing layer varies with the concentration of the target gas. Also, the performance analysis of sensors has been compared with the experimental results. Further, we have also derived a mathematical expression connecting the relationship between the concentration of gas and the rate of change of resistance. The resistance change is observed to be proportional to the target gas concentration. A signal conditioning circuit was also designed for providing a user-friendly interface for monitoring the gas concentration. The simulation of the signal conditioning circuit was done using Proteus Design Suite. This work will aid researchers to define and predict the behaviour of gas sensors.





2018 ◽  
Vol 18 (18) ◽  
pp. 7544-7550 ◽  
Author(s):  
Aparna Mohan ◽  
Mohanasankar Sivaprakasam ◽  
Boby George ◽  
V. Jagadeesh Kumar


Author(s):  
Nico Krauter ◽  
Vladimir Galindo ◽  
Thomas Wondrak ◽  
Sven Eckert ◽  
Gunter Gerbeth

Abstract The Eddy Current Flow Meter is a reliable and robust inductive sensor for the measurement of flowrates in liquid metal flows. This kind of sensor is usually being used in pipe flows where the flow is mostly parallel to the sensor axis. When this sensor is used as part of the safety instrumentation above the subassemblies in liquid metal cooled fast reactors, the flow angle may change rapidly according to the conditions within the reactor. In this paper we investigate the performance of the Eddy Current Flow Meter in flows inclined to the sensor axis by numerical simulations as well as model experiments. We demonstrate that the Eddy Current Flow Meter yields reliable results for flow angles up to 30° while the sensitivity of the sensor is significantly reduced for larger angles.



Author(s):  
S. Suresh Kumar ◽  
Sudheer Patri ◽  
R. K. Sharma ◽  
R. Punniamoorthy ◽  
Vishal D. Paunikar ◽  
...  


2020 ◽  
Vol 69 (11) ◽  
pp. 8763-8772
Author(s):  
Shahid Malik ◽  
Meraj Ahmad ◽  
Laxmeesha Somappa ◽  
Tarikul Islam ◽  
Maryam Shojaei Baghini


Micromachines ◽  
2019 ◽  
Vol 10 (4) ◽  
pp. 237 ◽  
Author(s):  
Jiawen Chen ◽  
Jianhua Li ◽  
Lixin Xu

In this paper, a highly integrated amorphous wire Giant magneto-impedance (GMI) magnetic sensor using micro electron mechanical system (MEMS) technology is designed, which is equipped with a signal conditioning circuit and uses a data acquisition card to convert the output signal of the circuit into a digital signal. The structure and package of the sensor are introduced. The sensor sensing principle and signal conditioning circuit are analyzed. The output of the sensor is tested, calibrated, and the relationship between the GMI effect of the amorphous wire and the excitation current frequency is explored. The sensor supplies voltage is ±5 V, and the excitation signal is a square wave signal with a frequency of 60 MHz and an amplitude of 1.2 V generated by the quartz crystal. The sensor has the largest GMI effect at 60 MHz with a sensitivity of 4.8 V/Oe and a resolution of 40 nT.