scholarly journals Effect of Some Disinfectant Solutions on the Adherence of Candida albicans to Three Types of Acrylic Resin Denture Base Materials

2020 ◽  
Vol 7 (2) ◽  
pp. 81-89
Author(s):  
Seeran M. Ahmed ◽  
◽  
Nadia T. Jaffer ◽  
2017 ◽  
Vol 6 (2) ◽  
pp. 17
Author(s):  
Angela Evelyna ◽  
Dahlia Sutanto ◽  
Elizabeth Tiffany

Maintaining acrylic denture hygiene is a necessary to prohibit the growth of several oral fungi such as Candida albicans. Candida albicans are the main etiological microorganism of denture stomatitis. One of the ways to clean denture is by immersion on synthetic denture cleaner liquid such as oxygenizing denture cleaners. However, synthetic denture cleaner have several limitation due to its biocompatibility on human body especially oral tissue. Chitosan is a derivate of chitin, a natural compound of sea creature exosceleton. Chitosan have antifungi and antibacterial nature. The objective of this study is to evaluate the antifungi efectifity of chitosan 2% on acrylic heatcured and compare it with oxygenizing denture cleaner. Aquades is used as a control. The sample consists of 15 acrylic heatcured bars (10x10x2 mm) prepared by contamination on Candida albicans suspensions at temperature 37°C for 24 hours and immersed on 3 different treatments wich are chitosan 2%, oxygenizing denture cleanser, and aquades as control and then, the solutions are being vibrate and put into sabouraud dextrose agar medium. The colony of Candida albicans counted manually. Result shows, highest mean of Candida albicans colony on aquades group (365,66 CFU/plate), followed by oxygenizing denture cleanser treatment (178,33 CFU/plate). The smallest number colony of Candida albicans are found at chitosan 2% treatment (45,33 CFU/plate). Statistical analysis using ANOVA one way shows F=9.826 and p=0, this means, there is minimal one pair of groups with very significant differential (p<0,01) which are chitosan 2% and oxygenizing denture cleanser compared to aquades as control. The difference between those two treatments also significant. Conclusions of this study is that chitosan 2% solution have a sifnificant effect on prohibiting the growth of Candida albicans colony on acrylic heatcured denture base materials. The effectivity of this solution is significantly higher than oxygenizing denture cleanser treatment.


2018 ◽  
Vol 15 (4) ◽  
pp. 449-454
Author(s):  
Baghdad Science Journal

This work aims to investigate the tensile and compression strengths of heat- cured acrylic resin denture base material by adding styrene-butadiene (S- B) to polymethyl methacrylate (PMMA). The most well- known issue in prosthodontic practice is fracture of a denture base. All samples were a blend of (90%, 80%) PMMA and (10%, 20%) S- B powder melted in Oxolane (Tetra hydro furan). These samples were chopped down into specimens of dimensions 100x10x2.5mm to carry out the requirements of tensile tests. The compression strength test specimens were shaped into a cylinder with dimensions of 12.7mm in diameter and 20mm in length. The experimental results show a significant increase in both tensile and compression strengths when compared to control (standard) results for the preparation material.


2019 ◽  
Vol S (1) ◽  
pp. 7-10
Author(s):  
Ahmed Asim Saeed Al-Ali ◽  
◽  
Ammar k. Al-Noori ◽  
Amer A. Taqa ◽  
◽  
...  

Objectives: Compare tensile and transverse strength of new copolymers for denture base. Materials and methods: The specimens were prepared from heat cured acrylic resin with three types of additives: Acryester B, Ethoxycarbonylethylene, and Propenoic acid at a percentage of 5% and 10%. The tensile and transverse strains were tested, recorded and compared. Results: The analysis of variance display statistically significant difference. The p-value was 0.001 for each of tensile and transverse strain tests. Conclusions: The tensile strength of the novel copolymers increased. The transverse strength of some of the novel copolymers increased.


Author(s):  
Irene Edith Rieuwpassa ◽  
Iman Sudjarwo ◽  
Sumintarti S ◽  
Susilowati Mudjari ◽  
Harun Achmad ◽  
...  

2012 ◽  
Vol 4 (4) ◽  
pp. 225-228 ◽  
Author(s):  
Camila A. Zamperini ◽  
Patricia C. S. Schiavinato ◽  
Ana C. Pavarina ◽  
Eunice T. Giampaolo ◽  
Carlos E. Vergani ◽  
...  

2008 ◽  
Vol 9 (4) ◽  
pp. 67-74 ◽  
Author(s):  
Behnaz Ebadian ◽  
Mohammad Razavi ◽  
Solmaz Soleimanpour ◽  
Ramin Mosharraf

Abstract Aim Controversy continues regarding the biocompatibility of denture base materials. One method to evaluate the biocompatibility of materials is in an animal study. Using dogs as subjects, the purpose of this study was to evaluate the vestibular tissue reaction to cobalt chromium (Co-Cr), heat cure acrylic resin, and acrylic resin mixed with aluminum oxide (Al2O3) compared with a control group using the histopathologic method. Methods and Materials Twelve disk shape samples (2 mm × 8 mm) in four groups of Co-Cr, acrylic resin, acrylic resin mixed with a 20% weight ratio of Al2O3, and a control group (Teflon) were fabricated. In one stage surgery two samples of each material (8 samples) was implanted in the buccal vestibule of each dog (n=6), subcutaneously. At 45 and 90-day intervals, half of the samples were excised along with peripheral tissue to assess the presence of inflammation by grading on a scale from 0 to 3 and the presence of a fibrotic capsule using histological observations. Data were analyzed using the Kruskal-Wallis, Mann-Whitney, and Tau b Kendal tests. Results Tissue reaction between Co-Cr and the control group was significant (P=0.02), but it was not significant between other groups. There was no significant difference between the 45 and 90-day postinsertion samples. The formation of fibrotic capsule groups was significant (P=0.01). It was significant between the Co-Cr and acrylic resin groups (P=0.01) and the acrylic resin and control groups (P=0.01). Conclusion The Co-Cr group was more toxic than the other groups. The inflammation increased during time. The inflammation in two acrylic groups was greater than the control and less than the Co-Cr group. The formation of fibrotic capsule, except in the acrylic resin with Al2O3 group, increased over time. Clinical Significance Co-Cr alloys are toxic and can produce damage to living tissue. Heat cure acrylic resin materials have less toxicity, and their use is safer than Co-Cr alloys. Citation Ebadian B, Razavi M, Soleimanpour S, Mosharraf R. Evaluation of Tissue Reaction to Some Denture-base Materials: An Animal Study. J Contemp Dent Pract 2008 May; (9)4:067-074.


2011 ◽  
Vol 2 (3) ◽  
pp. 237-242
Author(s):  
Achut R Devarhubli ◽  
VK Subbarao ◽  
NP Patil

ABSTRACT Over the years researchers have reported on the frequency and distribution of yeast in the oropharynx of apparently normal individuals and those with systemic or mycotic diseases wearing dentures. Few workers have taken into consideration the role played by the legion of denture base materials on the occurrence and progression of denture stomatitis. Hence this study was undertaken with the objective of evaluating the in vitro adherence of Candida albicans to different denture base materials namely reinforced polymethyl methacrylate, Nonreinforced polymethyl methacrylate and Cobalt chrome alloy of which chrome cobalt alloy showed less adherence to candidal cells compared to the two polymethyl methacrylate resins.


1999 ◽  
Vol 81 (2) ◽  
pp. 207-214 ◽  
Author(s):  
Donna L. Dixon ◽  
Larry C. Breeding ◽  
Tracy A. Faler

2015 ◽  
Vol 3 (3) ◽  
pp. 455-461
Author(s):  
Mohamed M. El-Zawahry ◽  
Ahmed A. El-Ragi ◽  
Mohamed I. El-Anwar ◽  
Eman Mostafa Ahmed Ibraheem

AIM: The objective of the present study was to evaluate the effect of different denture base materials on the stress distribution in TMJ articular disc (AD) in complete denture wearers.MATERIAL AND METHODS: Two three dimensional Finite Element (FEA) models of an individual temporomandibular joint (TMJ) were built on the basis CT scan. The FEA model consisted of four parts: the condyle, the articular disc, the denture base, and the articular eminence skull. Acrylic resin and chrome-cobalt denture base materials were studied. Static loading of 300N was vertically applied to the central fossa of the mandibular second premolar. Stress and strain were calculated to characterize the stress/strain patterns in the disc.RESULTS: The maximum tensile stresses were observed in the anterior and posterior bands of (AD) on load application with the two denture base materials. The superior boundaries of the glenoid fossa showed lower stress than those on the inferior boundaries facing the condyle.CONCLUSIONS: Within the limitations of the present study it may be concluded that: The denture base material may a have an effect in stress-strain pattern in TMJ articular disc. The stiffer denture base material, the better the distribution of the load to the underling mandibular supporting structures & reducing stresses induced in the articular disc.


Sign in / Sign up

Export Citation Format

Share Document