scholarly journals Strength Analysis of the Marine Weapon’s Construction

Naše more ◽  
2021 ◽  
Vol 68 (3) ◽  
pp. 167-174
Author(s):  
Stanisław Milewski ◽  
◽  
Bogdan Szturomski ◽  
Radosław Kiciński

Due to the modernization of warships, it was necessary to carry out strength calculations for the newly assembled devices, for which there were no detailed technical requirements. The authors try to present and harmonize the requirements for naval military structures. The lack of experimental verification of newly built systems was indicated. Therefore the finite element method was used to determine the durability of the critical design elements. There is no explicit reference load in the literature, so the authors present a general solution to one of the worst cases. The work presents the cannon structure elements exposed to damage during the underwater explosion load, using the proposed methodology. The proposed method is sufficient to calculate individual ship cases. However, in the case of hull strength analysis, more complex algorithms should be used.

2018 ◽  
Vol 55 (1) ◽  
pp. 1-4
Author(s):  
Elena Felicia Beznea ◽  
Ionel Chirica ◽  
Adrian Presura ◽  
Ionel Iacob

The paper is treating the strength analysis of the main deck structure of an inland navigation catamaran for 30 passengers. The main deck should have high stiffness and high strength to resist to external loading and endure high stresses from combined bending and torsion loads. Different materials for sandwich structure of the deck have been analysed by using the Finite Element Method in order to determine the solution which accomplish better designing criteria regarding allowable stress and deformations and total weight.


1982 ◽  
Vol 11 (4) ◽  
pp. 310-327
Author(s):  
H. Irokazu ◽  
M. Inami ◽  
Yoshio Nakahara

Methods for analysing coated plain-weave fabric which has properties of nonlinear elasticity have not yet been satisfactorily developed. In this paper, a method which is promis ing for use in engineering applications like the strength analysis of membrane structures is presented. The finite element method using a rectangular element consisting of plain-weave fabric and coating material which is assumed to be an isotropic elastic plate of plane stress is applied to the method. Verification of the me thod is made by using uniaxial stress-strain responses. A square piece of coated plain-weave fabric with a square hole in it is analyzed as an example of application of the present method. Key Words: coated plain-weave fabrics; finite element method; nonlinearly elastic biaxial response; geometrically nonlinear prob lem ; incremental approach.


Author(s):  
E. V. Barmekova

The paper presents the strength analysis of variable rigidity slabs on elastic support with the variable subgrade ratio. The analysis is based on a solution of the differential equation of the slab flexure using the finite element method. The results are obtained for different slabs on the elastic support. The results are presented for the different thickness of the upper layer of the two-layer slab on the elastic support with the variable subgrade ratio.


2017 ◽  
Vol 8 (1) ◽  
pp. 11-19
Author(s):  
Miroslav Blatnický ◽  
Ján Dižo ◽  
Stasys Steišūnas

Abstract In this article the strength analyses of weights boxes are presented. Boxes are designed as a welded steel structure at which weights with total mass almost ten tons are stored in them. These boxes are an integral part of a mechanism intended for calibration of the mass measurement device. The article contains on one hand the basic scope of the theory of elasticity and strength analysis and on the other hand the numerical computations of the structure by using the Finite Element Method. Based on results the structure of weights boxes was modified in order to satisfy the defined safety factor.


2011 ◽  
Vol 204-210 ◽  
pp. 332-336
Author(s):  
Tao Chi ◽  
Zhong Fu Wang

In order to evaluate the impact of crankshaft structure parameters on the transition strength of main journal and crank arm, this paper takes the crankshaft of V8 engine as the research object, using the finite element method to analyze, and then processing the experimental results with orthogonal experimental method throughout the experimental design, with the crankshaft parameters’ significant analysis of the crank arm overlap degree, main journal diameter, main journal length, crank pin diameter, crank pin length, etc, to obtain their impacts on the strength, and provide the instructive recommendations of crankshaft design and optimization.


2020 ◽  
Vol 313 ◽  
pp. 00034
Author(s):  
Pavol Lengvarský ◽  
Martin Mantič ◽  
Róbert Huňady

The special type of C-hook is investigated in this paper. The C-hook is designed to carry a special load, where is not possible to use classical hooks or chain slings. The designed hook is consisted of two arms that ensure the stability of the load being carried. The finite element analysis is performed for the control of the stress and deformation state in the whole hook. The fatigue analysis is performed for the check of a lifetime of C-hook.


2005 ◽  
Vol 05 (02) ◽  
pp. 375-382 ◽  
Author(s):  
R. CONTRO ◽  
P. VENA ◽  
D. GASTALDI ◽  
G. FRANZOSO

The paper addresses the biomechanical compatibility of an interspinous implant used for "dynamic stabilization" of a diseased intervertebral disc. A comparison between the behaviour of a titanium alloy ( Ti 6 Al 4 V ) implant and that of a superelastic alloy ( Ni - Ti ) implant has been carried out. The assessment of the biomechanical compatibility was achieved by means of the finite element method, in which suitably implemented constitutive laws for the materials have been used. The L4–L5 lumbar system in healthy state has been assumed as target for a biomechanically compatible implant. The L4–L5 system with the interspinous implant subjected to compressive force and bending moments has been simulated. A strength analysis for the bearing bone tissue in the posterior processes was also carried out. The results have shown that both implants were able to decrease the force on the apophyseal joints; however, the titanium-based implant exhibited a low biomechanical compatibility under extension-flexion in the sagittal plane; whereas the Ni - Ti exhibited a higher compatibility.


Sign in / Sign up

Export Citation Format

Share Document