scholarly journals Cementless bipolar hemiarthroplasty for displaced fracture neck of femur with modular hydroxyapatite coated stem in elderly with cardiopulmonary co-morbidities

Author(s):  
Towseef Ahmad Bhat ◽  
Zameer Ali ◽  
Amara Gulzar ◽  
Furqaan Mirza

Background: Bipolar hemiarthroplasty is one of the common procedures done for fracture neck of femur in elderly.  Debate about Cemented or cementless is still on. Cementing increases perioperative mortality by causing significant hemodynamic changes or embolization. Patients with cardiopulmonary complications are at higher risk of cementing complications. We report our series of 31 cases of fracture neck of femur with cardiopulmonary diseases operated over 2 years with modular cementless bipolar hemiarthroplasty.Methods: 31 elderly patients with cardiopulmonary co-morbidities (age=75 to 97 years) with displaced femoral neck fractures were operated between January 2011 to December 2013. Cementless bipolar hemiarthroplasty using hydroxyapatite coated stem was done by single surgeon using same implant in all the patients through anterolateral approach. Clinical and radiological follow-up was done with mean follow up of 54 months (36-72 months).Results: Total 31 cases with cardiopulmonary comorbidities were operated. The average follow up was 54 months. No intraoperative mortality was seen. 3 patients had splitting of femur during canal preparation. 1 patient died due to cardiac arrest in the post-operative period. 1 patient had surgical site infection. 3 patients had hemodynamic abnormalities and 1 patient had significant limb length discripency (1.5 cm). 2 patients died in the follow up because of comorbidities.  27 patients reached to pre-injury status with average harris hip score of 86 at final follow up.Conclusions: Cementless bipolar hemiarthroplasty with hydroxyapatite coated stem is a good option for femoral neck fractures in elderly patients with cardiopulmonary complications without risking the harmful effects of cementing.

2021 ◽  
Vol 15 (5) ◽  
pp. 988-991
Author(s):  
Zamir Hussain Tunioi ◽  
Rizwan Ali Jhatiyal ◽  
M Azeem Akhund ◽  
M Kashif Abbasi ◽  
L Das Maheshwari ◽  
...  

Aim: To evaluate the functional outcome of bipolar hemiarthroplasty in intracapsular fracture neck of femur. Study design: Descriptive cross sectional study. Place and duration of study: Department of Orthopaedic Surgery & Traumatology, Peoples Medical University Hospital, Shaheed Benazir Abad from 1st December 2017 to 31st December 2020. Methodology: Sixty six cases of intracapsular femoral neck fractures with age ranging from 50 year to 75 year of either gender who were ambulatory before injury were included; while basicervical, younger than 50 years, with neuromuscular disorder, unfit for surgery, open fracture, bilateral injuries, osteoarthritis of hip, Rheumatoid, Gouty, pathological fractures, bedridden & who did not give consent for study, were excluded from the study. Functional outcome assessed by Harris hip score & data analyzed by SPSS version 23. Results: Twenty six (59.09%) were male and 40 (40.91%) were female with mean age of 64.3±7.77 year. Average time from injury to hospital arrival was 14.7±6.8 hours. Average time from hospitalization to surgery was 4.67±2.23 days. Average time of surgery was 55.67±9.9 minutes. Average hospital stay was 9.7±4.3 days. The average time of follow-up was 18.45±7.63 months. Conclusion: Bipolar implant is safe, effective, reliable, stable and cost effective implant for intracpsular fracture of femoral neck in elderly populace. The 66.66% of patients have satisfactory Harris hip score in follow up duration of 18.45±7.63 months. Keywords: Functional, Outcome, Femoral neck fractures, FNF, Bipolar, Hemiarthroplasty, HHS


Author(s):  
Raja X. ◽  
Arjun Sarvesh ◽  
Karthikeyen M. ◽  
A. E. Manoharan

<p class="abstract"><strong>Background:</strong> Femoral neck fractures occur most commonly in elderly females and are a major cause of morbidity and mortality in this age group and require immediate and appropriate management. Aim of the study was to compare the functional outcome of unipolar Austin Moore's prosthesis (AMP) hemiarthroplasty (HA) and bipolar (BHA) HA with femoral neck fractures using Harris hip score system.</p><p class="abstract"><strong>Methods:</strong> The study was conducted on 60 patients aged above 50 years with fractured neck of femur admitted in Vinayaka missions Kirupananda Variyar medical college and hospital from August 2017 to August 2019. Patients with femoral neck fracture were allocated randomly to have 30 cases of AMP.</p><p class="abstract"><strong>Results:</strong> Out of the 60 cases, the patients in the bipolar (nonmodular) HA group II showed better functional outcomes compared to unipolar (AMP) HA group I after six months follow-ups. At 12 months of follow-up, there was no significant difference between group I (AMP) and group II (BHA).</p><p class="abstract"><strong>Conclusions:</strong> Our study demonstrates, hemiarthroplasty of the hip for femoral neck fractures is a good option in elderly patients. The mortality and morbidity are not high, the operative procedure is simple, complications are less disabling, early weight-bearing and functional results are satisfactory and second surgery are less frequently required.</p>


Author(s):  
Abhishek Kalantri ◽  
Sunil Barod ◽  
Dilip Kothari ◽  
Archana Kothari ◽  
Ashok Nagla ◽  
...  

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Hip fractures in older patients are associated with impaired mobility, excess morbidity and mortality, and loss of independence. This study was aimed at evaluating the outcome of hemiarthroplasty, by assessing the quality of life and degree of function in the operated limb.</span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">Out of 30 patients treated in this manner, all cases were available for follow-up period of 6 months. Patients of age 60 years and above, diagnosed with fracture neck of femur, were included in the study</span>.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">Majority of patients belongs to age group 60-69 years was 56.7% Females were more common 56.7% than males in the present study. About 13.3% patients sustained the injury due to a fall from a height and 23.3% due to a road traffic accident. About 20 patients (60%) had a stay of less than 20 days in hospital. In our study Harris hip score, at end of six month ranged from 35 to 94.6. At final 6 months follow-up by Harris hip scoring system, 53.33% had excellent result, 33.3% had good results, 16.67% had fair results and 6.67% had poor results. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">We conclude that hemiarthroplasty for fracture neck of femur is a good option in elderly patients. The mortality and morbidity are not high, operative procedure is simple, complications are less disabling. Early functional results are satisfactory.</span></p>


Author(s):  
H. D. Veeranna ◽  
K. B. Ravi ◽  
K. Anudeep Kumar

<p class="abstract"><strong>Background:</strong> Intracapsular femoral neck fractures are common in elderly population after a simple fall. To avoid the drawbacks of internal fixation and for the early mobilization, hemiarthroplasty is performed in elderly. The aim of this study is to compare the outcome AMP with uncemented bipolar prosthesis in geriatric patients.</p><p class="abstract"><strong>Methods:</strong> 51 patients above 60 years and an acute displaced fracture of the femoral neck were randomly allocated to treatment by either AMP (Austin Moore prosthesis) or bipolar hemiarthroplasty, in the Department of Orthopaedics, Sri Siddhartha medical college, Tumkur between April 2014 and May 2017. The patients were summoned at 6 weeks, 12 weeks, 6 months and 1 year. Functional outcome was assessed and compared with modified Harris hip score and radiological parameters.<strong></strong></p><p class="abstract"><strong>Results:</strong> The mean Harris hip score in bipolar and AMP group was 86.31±12.1 and 79.86±15.42, respectively (p=0.182). The range of motion was 204.52±28.2 and 183.62±36 (p=0.014) respectively. Functional activities like use of public transport and ability to wear shoe or socks was better with bipolar group. Incidence of complications like painful hip, posterior dislocation, periprosthetic fracture and acetabular erosion was encountered in AMP group.</p><p class="abstract"><strong>Conclusions:</strong> The use of uncemented bipolar endoprosthesis in the management of displaced femoral neck fractures in the elderly was associated with better mean Harris hip score and incidence of complications was limited. Hence, bipolar would be a better option in elderly patients with fracture neck of femur.</p><p class="abstract"> </p>


2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110122
Author(s):  
Wenlu Liu ◽  
Huanyi Lin ◽  
Xianshang Zeng ◽  
Meiji Chen ◽  
Weiwei Tang ◽  
...  

Objective To compare the clinical outcomes of primary metal-on-metal total hip replacement (MoM-TR) converted to uncemented total hip replacement (UTR) or cemented total hip replacement (CTR) in patients with femoral neck fractures (AO/OTA: 31B/C). Methods Patient data of 234 UTR or CTR revisions after primary MoM-TR failure from March 2007 to January 2018 were retrospectively identified. Clinical outcomes, including the Harris hip score (HHS) and key orthopaedic complications, were collected at 3, 6, and 12 months following conversion and every 12 months thereafter. Results The mean follow-up was 84.12 (67–100) months for UTR and 84.23 (66–101) months for CTR. At the last follow-up, the HHS was better in the CTR- than UTR-treated patients. Noteworthy dissimilarities were correspondingly detected in the key orthopaedic complication rates (16.1% for CTR vs. 47.4% for UTR). Statistically significant differences in specific orthopaedic complications were also detected in the re-revision rate (10.3% for UTR vs. 2.5% for CTR), prosthesis loosening rate (16.3% for UTR vs. 5.9% for CTR), and periprosthetic fracture rate (12.0% for UTR vs. 4.2% for CTR). Conclusion In the setting of revision of failed primary MoM-TR, CTR may demonstrate advantages over UTR in improving functional outcomes and reducing key orthopaedic complications.


2021 ◽  
Author(s):  
WENJING CHENG ◽  
GUOZHENG - DING

Abstract Background: At present, there is a higher complication rate after treatment of femoral neck fractures with three parallel hollow nails (PHN) in the young Pauwels type Ⅲ femoral neck fractures.For better effect,F-shape hollow nails(FHN) is used to treat femoral neck fractures.The purpose of this study is to compare the clinical efficacy of FHN and PHN and provide reference for clinical application.Methods: Thirty-eight consecutive patients admitted from January 2017 to January 2020 were selected for the study. According to random number table method, the patients were divided into two groups:group A (FHN) and group B (PHN). The gender, age, BMI, comorbidities, time from injury to operation and other general preoperative demographics were not statistically different (P>0.05). The data of the two groups can be comparable.The occurrence of avascular osteonecrosis of the femoral head (AVN), femoral neck shortening, hollow screw withdrawal was recorded in follow-up.Then, Harris hip score (HHS), pain visual analog score (VAS) of two group were obtained at the last follow-up. Results: The mean follow-up period after surgery was 21.4±10.1 (range, 14–29) months. There were 18 cases(mean age, 47.5±9.6) in group A, 20 cases (mean age, 48.6±10.1) in group B. There was no significant difference between the two groups in AVN, femoral neck shortening (P>0.05), the two groups had statistically significant differences in screw withdrawal (F=4.416, P<0.05). There was no significant difference in HHS and VAS between the two groups at the last follow-up (P>0.05).Conclusion: Three parallel hollow nails (PHN) and F-shape hollow nails (FHN) have similar short-term effects in the young Pauwels type Ⅲ femoral neck fractures, but the nail withdrawal rate of FNH is lower.


Sign in / Sign up

Export Citation Format

Share Document