scholarly journals A study of prospective analysis of unipolar versus bipolar hemiarthroplasty of hip joint in patients with fracture neck of femur

Author(s):  
Raja X. ◽  
Arjun Sarvesh ◽  
Karthikeyen M. ◽  
A. E. Manoharan

<p class="abstract"><strong>Background:</strong> Femoral neck fractures occur most commonly in elderly females and are a major cause of morbidity and mortality in this age group and require immediate and appropriate management. Aim of the study was to compare the functional outcome of unipolar Austin Moore's prosthesis (AMP) hemiarthroplasty (HA) and bipolar (BHA) HA with femoral neck fractures using Harris hip score system.</p><p class="abstract"><strong>Methods:</strong> The study was conducted on 60 patients aged above 50 years with fractured neck of femur admitted in Vinayaka missions Kirupananda Variyar medical college and hospital from August 2017 to August 2019. Patients with femoral neck fracture were allocated randomly to have 30 cases of AMP.</p><p class="abstract"><strong>Results:</strong> Out of the 60 cases, the patients in the bipolar (nonmodular) HA group II showed better functional outcomes compared to unipolar (AMP) HA group I after six months follow-ups. At 12 months of follow-up, there was no significant difference between group I (AMP) and group II (BHA).</p><p class="abstract"><strong>Conclusions:</strong> Our study demonstrates, hemiarthroplasty of the hip for femoral neck fractures is a good option in elderly patients. The mortality and morbidity are not high, the operative procedure is simple, complications are less disabling, early weight-bearing and functional results are satisfactory and second surgery are less frequently required.</p>

2021 ◽  
Vol 15 (5) ◽  
pp. 988-991
Author(s):  
Zamir Hussain Tunioi ◽  
Rizwan Ali Jhatiyal ◽  
M Azeem Akhund ◽  
M Kashif Abbasi ◽  
L Das Maheshwari ◽  
...  

Aim: To evaluate the functional outcome of bipolar hemiarthroplasty in intracapsular fracture neck of femur. Study design: Descriptive cross sectional study. Place and duration of study: Department of Orthopaedic Surgery & Traumatology, Peoples Medical University Hospital, Shaheed Benazir Abad from 1st December 2017 to 31st December 2020. Methodology: Sixty six cases of intracapsular femoral neck fractures with age ranging from 50 year to 75 year of either gender who were ambulatory before injury were included; while basicervical, younger than 50 years, with neuromuscular disorder, unfit for surgery, open fracture, bilateral injuries, osteoarthritis of hip, Rheumatoid, Gouty, pathological fractures, bedridden & who did not give consent for study, were excluded from the study. Functional outcome assessed by Harris hip score & data analyzed by SPSS version 23. Results: Twenty six (59.09%) were male and 40 (40.91%) were female with mean age of 64.3±7.77 year. Average time from injury to hospital arrival was 14.7±6.8 hours. Average time from hospitalization to surgery was 4.67±2.23 days. Average time of surgery was 55.67±9.9 minutes. Average hospital stay was 9.7±4.3 days. The average time of follow-up was 18.45±7.63 months. Conclusion: Bipolar implant is safe, effective, reliable, stable and cost effective implant for intracpsular fracture of femoral neck in elderly populace. The 66.66% of patients have satisfactory Harris hip score in follow up duration of 18.45±7.63 months. Keywords: Functional, Outcome, Femoral neck fractures, FNF, Bipolar, Hemiarthroplasty, HHS


Author(s):  
H. D. Veeranna ◽  
K. B. Ravi ◽  
K. Anudeep Kumar

<p class="abstract"><strong>Background:</strong> Intracapsular femoral neck fractures are common in elderly population after a simple fall. To avoid the drawbacks of internal fixation and for the early mobilization, hemiarthroplasty is performed in elderly. The aim of this study is to compare the outcome AMP with uncemented bipolar prosthesis in geriatric patients.</p><p class="abstract"><strong>Methods:</strong> 51 patients above 60 years and an acute displaced fracture of the femoral neck were randomly allocated to treatment by either AMP (Austin Moore prosthesis) or bipolar hemiarthroplasty, in the Department of Orthopaedics, Sri Siddhartha medical college, Tumkur between April 2014 and May 2017. The patients were summoned at 6 weeks, 12 weeks, 6 months and 1 year. Functional outcome was assessed and compared with modified Harris hip score and radiological parameters.<strong></strong></p><p class="abstract"><strong>Results:</strong> The mean Harris hip score in bipolar and AMP group was 86.31±12.1 and 79.86±15.42, respectively (p=0.182). The range of motion was 204.52±28.2 and 183.62±36 (p=0.014) respectively. Functional activities like use of public transport and ability to wear shoe or socks was better with bipolar group. Incidence of complications like painful hip, posterior dislocation, periprosthetic fracture and acetabular erosion was encountered in AMP group.</p><p class="abstract"><strong>Conclusions:</strong> The use of uncemented bipolar endoprosthesis in the management of displaced femoral neck fractures in the elderly was associated with better mean Harris hip score and incidence of complications was limited. Hence, bipolar would be a better option in elderly patients with fracture neck of femur.</p><p class="abstract"> </p>


Author(s):  
Towseef Ahmad Bhat ◽  
Zameer Ali ◽  
Amara Gulzar ◽  
Furqaan Mirza

Background: Bipolar hemiarthroplasty is one of the common procedures done for fracture neck of femur in elderly.  Debate about Cemented or cementless is still on. Cementing increases perioperative mortality by causing significant hemodynamic changes or embolization. Patients with cardiopulmonary complications are at higher risk of cementing complications. We report our series of 31 cases of fracture neck of femur with cardiopulmonary diseases operated over 2 years with modular cementless bipolar hemiarthroplasty.Methods: 31 elderly patients with cardiopulmonary co-morbidities (age=75 to 97 years) with displaced femoral neck fractures were operated between January 2011 to December 2013. Cementless bipolar hemiarthroplasty using hydroxyapatite coated stem was done by single surgeon using same implant in all the patients through anterolateral approach. Clinical and radiological follow-up was done with mean follow up of 54 months (36-72 months).Results: Total 31 cases with cardiopulmonary comorbidities were operated. The average follow up was 54 months. No intraoperative mortality was seen. 3 patients had splitting of femur during canal preparation. 1 patient died due to cardiac arrest in the post-operative period. 1 patient had surgical site infection. 3 patients had hemodynamic abnormalities and 1 patient had significant limb length discripency (1.5 cm). 2 patients died in the follow up because of comorbidities.  27 patients reached to pre-injury status with average harris hip score of 86 at final follow up.Conclusions: Cementless bipolar hemiarthroplasty with hydroxyapatite coated stem is a good option for femoral neck fractures in elderly patients with cardiopulmonary complications without risking the harmful effects of cementing.


2021 ◽  
Author(s):  
WENJING CHENG ◽  
GUOZHENG - DING

Abstract Background: At present, there is a higher complication rate after treatment of femoral neck fractures with three parallel hollow nails (PHN) in the young Pauwels type Ⅲ femoral neck fractures.For better effect,F-shape hollow nails(FHN) is used to treat femoral neck fractures.The purpose of this study is to compare the clinical efficacy of FHN and PHN and provide reference for clinical application.Methods: Thirty-eight consecutive patients admitted from January 2017 to January 2020 were selected for the study. According to random number table method, the patients were divided into two groups:group A (FHN) and group B (PHN). The gender, age, BMI, comorbidities, time from injury to operation and other general preoperative demographics were not statistically different (P>0.05). The data of the two groups can be comparable.The occurrence of avascular osteonecrosis of the femoral head (AVN), femoral neck shortening, hollow screw withdrawal was recorded in follow-up.Then, Harris hip score (HHS), pain visual analog score (VAS) of two group were obtained at the last follow-up. Results: The mean follow-up period after surgery was 21.4±10.1 (range, 14–29) months. There were 18 cases(mean age, 47.5±9.6) in group A, 20 cases (mean age, 48.6±10.1) in group B. There was no significant difference between the two groups in AVN, femoral neck shortening (P>0.05), the two groups had statistically significant differences in screw withdrawal (F=4.416, P<0.05). There was no significant difference in HHS and VAS between the two groups at the last follow-up (P>0.05).Conclusion: Three parallel hollow nails (PHN) and F-shape hollow nails (FHN) have similar short-term effects in the young Pauwels type Ⅲ femoral neck fractures, but the nail withdrawal rate of FNH is lower.


KYAMC Journal ◽  
2017 ◽  
Vol 8 (1) ◽  
pp. 10-14
Author(s):  
Md Ashraful Islam ◽  
Md Abdur Rashid ◽  
Md Rafiqul Islam ◽  
Md Masudar Rahman ◽  
Md Asmaul Hossain Khan ◽  
...  

Background: Femoral neck fractures are common in the elderly population. To avoid the poor outcome of internal fixation and for early mobilization, hemiarthroplasty is performed. However, there is inadequate evidence to support the choice between unipolar or bipolar hemiarthroplasty.Objectives: The aim of this study was to compare the outcome of unipolar with the bipolar prosthesis in geriatric patients.Methods: Forty-one patients above 60 years of age and an acute displaced fracture of the femoral neck were randomly allocated to treatment by either unipolar or bipolar hemiarthroplasty, in the Department of Orthopaedics at Khwaja Yunus Ali Medical College and Hospital, Enayetpur, Sirajgonj, Bangladesh in between December 2014 and February 2017. Functional outcome was assessed and compared using Harris hip score and radiological parameters with a follow-up of one year.Results: The two groups of patients with mean age of 67.3 in bipolar group and 75.6 in unipolar group did not differ in their pre-injury characteristics and perioperative parameters. The mean Harris hip score in bipolar and unipolar groups was 86.18±12.18 and 79.79±15.55, respectively (p=0.183); range of motion was 210.63±28.39 and 181.58±37(p=0.015) with bipolar and unipolar groups, respectively. Functional activities were better in the bipolar group. Complications like painful hip, posterior dislocation, periprosthetic fracture and acetabular erosion were encountered in unipolar prostheses.Conclusion: The use of bipolar endoprosthesis in the management of displaced femoral neck fractures in the elderly was associated with better mean Harris hip score and incidence of complications was limited. Hence, bipolar would be a better option in elderly patients with fracture neck of femur.KYAMC Journal Vol. 8, No.-1, Jul 2017, Page 10-14


2019 ◽  
Vol 10 ◽  
pp. 215145931984861 ◽  
Author(s):  
Skender Ukaj ◽  
Osman Zhuri ◽  
Fatime Ukaj ◽  
Vlora Podvorica ◽  
Kushtrim Grezda ◽  
...  

Background: Hip fractures are serious injuries associated with relatively high mortality rates and disabilities, commonly seen in elderly persons. There is an ongoing debate regarding the advantages of various hip arthroplasty devices. This study aimed to analyze the long-term advantages of 2 different surgical procedures and assess if the dislocation rate, Harris Hip Score (HHS), and functional independence measure (FIM) are more favorable in dual mobility (DM) than those in hemiarthroplasty (HA). Hypothesis: Dual mobility procedures provide better postoperative outcomes than HA in terms of HHS, FIM, and dislocation rate. Materials and Methods: The survey was a prospective, comparative interventional single-blinded study performed at the University Clinical Center of Kosovo, a tertiary health-care institution. A total of 94 patients underwent DM or conventional bipolar HA for repair of displaced femoral neck fractures within 2 weeks of injury. Primary outcomes were postoperative dislocation rate, FIM, and HHS. Secondary outcomes included duration of surgery, estimated intraoperative blood loss, time to first postoperative full weight-bearing, time to walking ability with and without crutches, mortality rate, and postoperative infection rate. Results: There were no significant differences for most parameters between the groups. We found a significant difference in the dislocation rate between the 2 groups, wherein there were no dislocations in the DM group and 3 dislocations in the HHS group (0% vs 6.4%). In terms of postoperative HHS at 12 months and 3 years, DM provided better outcomes (<0.034 and <0.014, respectively). Discussion: Dual mobility compares favorably to HA in terms of dislocation rate and HHS, while no difference was found for FIM. In order to have a more complete overview, we recommend more intense long-term studies including several heterogeneous parameters to compare the clinical outcomes between DM and HA. Level of evidence (with study design): Level II.


2022 ◽  
Author(s):  
Xuefeng Zhou ◽  
Sichao Gu ◽  
Li Li ◽  
Lei Xu ◽  
Xujin Wang ◽  
...  

Abstract Femoral neck system (FNS) , as a novel minimally invasive internal fixation device, has been gradually applied in the treatment of femoral neck fracture.However, there are few related clinical studies on FNS at present, especially there is no clinical report on FNS in treating GardenIII and IV femoral neck fractures. The aim of the present study was to compare the short-term clinical efficacy of FNS and multiple cannulated compression screws (MCCS) in the treatment of Garden III and IV femoral neck fractures. The data of 78 patients with femoral neck fracture who were admitted to three teaching hospitals affiliated to Anhui Medical University and received internal fixation with FNS and MCCS from June 2019 to December 2020 were collected for a retrospective study. There were 39 patients in both the FNS and MCCS groups. The basic data, perioperative data were recorded and compared between the two groups of patients. The results of the study are encouraging. The operation time was shorter in FNS group than that in MCCS group (p<0.001). The post-operative partial and complete weight-bearing time was earlier in FNS group than that in MCCS group (p<0.001). The Harris hip score in FNS group was higher than that in MCCS group (p<0.001). The incidence rate of lateral thigh irritation in FNS group and MCCS group was 0 (0/39) and 33.3% (13/39), respectively (χ2=15.600, p<0.001). The length of femoral neck shortening was significantly shorter in FNS group than that in MCCS group (t=-5.093, p<0.001). In conclusion, The application of FNS for Garden III and IV femoral neck fractures can shorten the operation time, reduce the frequency of intraoperative fluoroscopy, and facilitate the recovery of hip joint function, so it provides a novel choice for the treatment of Garden III and IV femoral neck fractures in young people.


2018 ◽  
Vol 25 (09) ◽  
pp. 1317-1322
Author(s):  
Muhammad Jawad Ahmed ◽  
Maryam Shahid ◽  
Muhammad Hammad Ahmed ◽  
Bilal Nazarq

Objectives: To compare of functional outcomes in terms of post-operativemobility for unipolar versus bipolar un-cemented hemiarthroplasty in elderly patients withdisplaced intracapsular femoral neck fractures. Study Design: Randomized Control Trial.Setting: Department of Orthopedics Bahawal Victoria Hospital, Bahawalpur. Period: April 2015to October 2016. Methodology: Sample size is (calculated by taking n6 =138, confidenceinterval 95, power of study 80, P1= 33%, P2=13%) 69 in each group. Sampling technique usedwas non probability consecutive sampling. All patients who meet the inclusion criteria presentingto orthopedic unit of Nishtar Hospital Multan with fracture neck of femur were selected for study.Patients were divided into two groups randomly by lottery method and enrolled for unipolaror bipolar hemiarthroplasty. Chi-square test was used to compare outcome variable in bothgroups. A p-value < 0.05 was considered statistically significant. Effect modifiers like age andsex was controlled by stratification. Chi square test was applied to see significant difference.Results: Overall, there were 100% (n=138) patients in this study, both genders. The mean ageof the patients was 66.35±4.29 years. (Range: 60 to 80years)Mean age and SD of group A (nowalking aid) was 54.52 ± 3.10 and in group B (walking aid) 54.99 ± 3.19. Time up go score wasnoted as successful 33.3% (n=46) and 66.7% (n=92) as unsuccessful. Walking aid was notedin 65.2% (n=90) patients. Functional outcome was noted as good in 26.8% (n=37) patientsand noted as bad in 73.2% (n=101) patients. Out of 100% (n=38) patients, good outcomewas 26.3% (n=10) unipolar and 73.7% (n=28) bipolar. Out of 100% (n=100) Bad outcomewas 59% unipolar and bipolar 41%. Conclusion: Functional outcome in term of mobility isbetter in case of bipolar prosthesis as compared to unipolar. Thus in our conclusion bipolarprosthesis is preferred procedure as compared to unipolar hemiarthroplasty in treating patientswith displaced intracapsular femoral neck fracture.


2021 ◽  
Author(s):  
Sheng-Bo Nie ◽  
Jun-Feng Liu ◽  
Jiang-Hua Zhu ◽  
Zi-Fei Zhou ◽  
Lei Zhang ◽  
...  

Abstract Background: Preoperative posterior tilt is a risk factor for fixation failure in femoral neck fractures. This study aimed to evaluate the configuration of anterior positioning screw in proximal femoral plating in the treatment of retroverted femoral neck fractures in terms of resisting posterior tilt.Methods: We retrospectively analyzed patients with retroverted femoral neck fractures who were fixed by proximal femoral plating from January 2014 to August 2019. All patients were divided into two groups according to screw configuration: anterior long-threaded screw (ALTS, n = 36) and normally short-threaded screws (NTS, n = 46). Baseline characteristics were reviewed and radiological and clinical outcomes were analyzed. Logistic regression analysis was used to identify risk factors for developing posterior tilt.Results: Demographic data showed no significant difference. Increased posterior tilt was lower in the ALTS group (3.2°, 2.1 – 4.3°) than that in the NTS group (5.3°, 4.2 – 8.3°) (p < 0.001), and the percentage of people with > 5° of posterior tilt was also lower in the ALTS group (5, 13.9% vs. 24, 52.2%; p < 0.001). Femoral neck shortening (FNS) was lower in the ALTS group (3.1 (2.1 – 4.7) mm vs. 4.3 (3.1 – 6.3) mm, p = 0.003), though not statistically significant when using 5 mm as the cut-off value. Harris Hip Score in the ALTS group was higher than that in the NTS group (87.0, 84.0 – 90.0 vs. 82.0, 76.0 – 84.5; p < 0.001). Postoperative complications including delayed union, nonunion, and avascular necrosis were comparable between the groups. Multivariable analysis identified posterior comminution (OR 15.9, 95% CI 3.6 – 70.3, p < 0.001), suboptimal reduction quality (OR 12.0, 95% CI 2.6 – 56.1, p = 0.002), and NTS configuration (ref: ALTS configuration) (OR 21.9, 95% CI 4.1 – 116.4, p < 0.001) as risk factors for developing posterior tilt.Conclusions: Configuration of anterior positioning screw in proximal femoral plating provides better resistance against posterior tilt in the fixation of retroverted femoral neck fractures. Also, posterior comminution, suboptimal reduction, and NTS configuration (ref: ALTS) are risk factors for developing posterior tilt.Trial registration: Retrospectively registered.


Sign in / Sign up

Export Citation Format

Share Document