scholarly journals Research on the decision of state maintenance for transmission line based on set pair analysis

2021 ◽  
Vol 71 (1&2) ◽  
pp. 17
Author(s):  
Shiyang Zhu ◽  
Le Wang

Overhead transmission lines are important parts of a power system; their operation state directly affects the reliability level of the entire power system. With the in-depth development of state maintenance work for power grids, correctly evaluating the reliability of overhead transmission lines is the key to successful maintenance. A maintenance decision model for transmission lines is established in this study based on set pair analysis to achieve human financial control and low maintenance efficiency. Full consideration is provided to the influence of environmental factors, and a theoretical basis for transmission line maintenance decision is established.

Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 67 ◽  
Author(s):  
Jian Hu ◽  
Xiaofu Xiong ◽  
Jing Chen ◽  
Wei Wang ◽  
Jian Wang

The overload degree of a transmission line is represented by currents in traditional overload protection, which cannot reflect its safety condition accurately. The sudden rise in transmission line current may lead to cascading tripping under traditional protection during power flow transfer in a power system. Therefore, timely and accurate analysis of the transient temperature rise of overhead transmission lines, revealing their overload endurance capability under the premise of ensuring safety, and coordination with power system controls can effectively eliminate overloading. This paper presents a transient temperature calculation method for overhead transmission lines based on an equivalent thermal network. This method can fully consider the temperature-dependent characteristics with material properties, convective heat resistance, and radiation heat and can accurately calculate the gradient distribution and response of the conductor cross-section temperature. The validity and accuracy of the proposed calculation method are verified by a test platform. In addition, a multi-parameter thermal protection strategy is proposed on the basis of the abovementioned calculation method. The protection can adequately explore the maximum overload capability of the line, and prevent from unnecessary tripping to avoid the expansion of accidents. Finally, the validity of the proposed protection is verified by the modified 29-bus system.


2014 ◽  
Vol 15 (6) ◽  
pp. 513-526
Author(s):  
Wanjing Xiu ◽  
Yuan Liao

Abstract Transmission lines are essential components of electric power grids. Diverse power system applications and simulation based studies require transmission line parameters including series resistance, reactance, and shunt susceptance, and accurate parameters are pivotal in ensuring the accuracy of analyses and reliable system operation. Commercial software packages for performing power system studies usually have their own databases that store the power system model including line parameters. When there is a physical system model change, the corresponding component in the database of the software packages will need to be modified. Manually updating line parameters are tedious and error-prone. This paper proposes a solution for streamlining the calculation of line parameters and updating of their values in respective software databases. The algorithms used for calculating the values of line parameters are described. The software developed for implementing the solution is described, and typical results are presented. The proposed solution is developed for a utility and has a potential to be put into use by other utilities.


2018 ◽  
Vol 58 ◽  
pp. 01002
Author(s):  
Abdula Abdurakhmanov ◽  
Sergey Glushkin ◽  
Vladislav Plotnikov ◽  
Andrey Shuntov

The reliability characteristics of the (auto)transformers and overhead transmission lines of the unified national electric grid are subjected to statistical analysis. It is shown that their scheduled outages for scheduled or unscheduled repairs, as well as maintenance, weaken the network layout much more than emergency repairs. At the same time, there was a noticeable deterioration in the (auto)transformers and overhead transmission line reliability indexes over the last 30 years, which requires the development and adoption of appropriate organizational and technical solutions.


2012 ◽  
Vol 614-615 ◽  
pp. 1394-1400
Author(s):  
Wen Qing Yang ◽  
Wei Cao ◽  
Jian Kun Wu ◽  
Lin Chen

Power transmission is a key link in power system. As the increase of power supply, the transmission capacity of the lines should be enlarged too. In the developed area, the right-of-way for transmission line is hard to be obtained. And converting the existing HVAC overhead transmission lines using HVDC technology could enhance the transmission capability. There are three possible plans for different HVAC transmission lines: single-pole HVDC, bi-pole HVDC and tri-pole HVDC.


Energies ◽  
2019 ◽  
Vol 12 (8) ◽  
pp. 1462 ◽  
Author(s):  
Zheng ◽  
Jia ◽  
Gong ◽  
Zhang ◽  
Pei

Compared with alternating current (AC) power grids, the voltage-sourced converter (VSC)-based direct current (DC) grid is a system characterized by “low damping”, as a result, once there is a short-circuit fault on the DC transmission line, the fault current will rise more sharply and the influence range will be much wider within the same time scale. Moreover the phenomenon that a local fault causes a whole power grid outage is more likely to occur. Overhead transmission lines (OHLs) have been regarded as the mainstream form of power transmission in future high-voltage, large-capacity and long-distance VSC-based DC grids. However, the application of overhead transmission lines will inevitably lead to a great increase in the probability of DC line failure. Therefore, research on how to isolate the DC fault line quickly is of great significance. Based on the technology route for fault line isolation using DC breakers, on the basis of in-depth analysis of traditional coordination strategy, an optimized coordination strategy between line main protection and a hybrid DC breaker for VSC-based DC grids using overhead transmission lines is proposed in this paper, which takes the start-up output signal of line main protection as the pre-operation instruction of the corresponding hybrid DC breaker. As a result, the risks of blockage of the modular multilevel converter (MMC) closer to the fault position and of damage to power electronic devices in main equipment can be reduced effectively. Finally, the proposed coordination strategy was verified and analyzed through simulation.


2014 ◽  
Vol 672-674 ◽  
pp. 799-802
Author(s):  
Xiao Gang Li ◽  
Li Xue Li ◽  
Yi Hui Zheng ◽  
Xin Wang ◽  
Jian You Yu ◽  
...  

Lightning overvoltage often leads to transmission lines trip, which is the weak link of power system. In this paper, 110-kV transmission line model is studied on the basis of the EMTP software. Several simulation models are established for back flashover lightning, induced lightning, shield failure. The transient process of lightning stroke is studied. According to the contrast of simulation results of three kinds of lightning, a set of discriminant basis to distinguish lightning on transmission line is put forward.


2014 ◽  
Vol 556-562 ◽  
pp. 1588-1591
Author(s):  
Xiu Bin Zhang ◽  
Ding Jun Wen ◽  
Ya Ming Sun ◽  
Hong Gang Chen

Lighting is one of the important reasons of transmission line trip accident. For 330kV and above ultra high voltage transmission line, lighting flashover more frequently occur. To reduce tripping rate effectively and fundamentally, lightning over voltage level should be analyzed besides anti-pollution flashover. In this paper, a simplified equivalent circuit model of a 330kV overhead transmission lines is established. The lightning over voltage of the transmission is analyzed and calculated. Method to reduce the lightning overvoltage is discussed.


Author(s):  
Yishuang Wang ◽  
Chao Yuan ◽  
Yongjie Zhai

The requirements of power system for the safety of overhead transmission lines are increasing. With the rapid development of mobile robot technology, the inspection of overhead transmission lines by inspection robots has become a research hotspot in recent years. Aiming at the task requirements of transmission line inspection robots and the environmental characteristics of transmission lines, researchers at home and abroad have developed a variety of inspection robots. However, most of these robots have problems such as inability to cross the strain tower, low obstacle crossing efficiency and poor safety. In order to solve the above problems, this paper proposes a new four-arm inspection robot mechanism. The robot can cross the strain tower with two different sets of arms working together. The rectangular frame structure on the walking arm improves the obstacle crossing efficiency of the robot, and the closed hanging mechanism ensures that the robot does not fall from the line. In this paper, the three-dimensional model of the robot is established, and the specific structure and motion parameters are given. Three typical obstacle-crossing modes are planned, and the motion analysis and force simulation analysis of the robot's obstacle-crossing process are carried out. The simulation result shows that the mechanism can efficiently cross the strain towers and common obstacles on the transmission line.


2014 ◽  
Vol 521 ◽  
pp. 330-333
Author(s):  
Yu Sheng Quan ◽  
En Ze Zhou ◽  
Hua Gui Chen ◽  
Xin Zhao

High voltage overhead transmission line is an important part of the power system to ensure the safe operation of the entire power system, which is of great significance. Power line fault not only has adverse effects to the social economy, and it may also affect the stability of the power system. Transmission line faults including permanent fault and transient fault are identified quickly and accurately, which has important practical engineering significance. This paper presents a method which can be used to identify the permanent fault and transient fault of double-circuit transmission line on the same tower, fault transient voltages and currents extracted from both ends of transmission lines are as a signal source which is decomposed into a series of harmonics in order to establish a criterion function, and then the transient and permanent fault can be identified based on the changes of criterion function value.


2020 ◽  
Vol 14 (1) ◽  
pp. 21-26
Author(s):  
S. SKRYPNYK ◽  
◽  
A. SHEINA ◽  

Most failures in electrical installations are caused by short circuits (short circuits), which occur as a result of a failure in the electrical strength of the insulation of the conductive parts. A short circuit is an electrical connection of two points of an electric circuit with different values of potential, which is not provided by the design of the device, which interferes with its normal operation. Short circuits may result from a failure of the insulation of the current-carrying elements or the mechanical contact of the non- insulated elements. Also called a short circuit is a condition where the load resistance is less than the internal resistance of the power source. The reasons for such violations are various: aging of insulation, breakages of wires of overhead transmission lines, mechanical damages of isolation of cable lines at ground works, lightning strikes in the transmission line and others. Most often, short-circuits occur through transient resistance, such as through the resistance of an electric arc that occurs at the point of damage to the insulation. Sometimes there are metallic short circuits in which the resistance of the electric arc is very small. The study of short circuits in the power grid is a major step in the design of modern electrical networks. The research is conducted using computer software, first by modeling the system and then simulating errors. A malfunction usually leads to an increase in the current flowing in the lines, and failure to provide reliable protection can result in damage to the power unit. Thus, short-circuit calculations are the primary consideration when designing, upgrading, or expanding a power system. The three-phase short circuit is the least likely. However, in many cases, the three-phase short circuit is associated with the most severe consequences, as it causes the highest power imbalances on the shafts of the generators. The study of transients begins with the mode of three-phase closure due to its relative simplicity in comparison with other types of asymmetry. In most cases, the analysis and calculation of the transient regime of the electrical system involves the preparation of a calculated scheme of substitution, in which the parameters of its elements are determined in named or relative units. The electrical substitution circuitry is used to further study the transients in the power system. The definition of electrical and electromagnetic quantities in relative units is widely used in the theory of electric machines. This is because it significantly simplifies the theoretical calculations and gives the results a generalized view in the practical calculations of currents and residual voltages at the short circuit. By the relative value of any value is understood as its relation to another value of the same name, taken as the base. So, before presenting any quantities in relative units, we need to choose the basic units. In the electrical system with increased voltages, the overall load capacity of the network increases, which in turn makes it possible to supply high-quality electrical energy over a greater distance. In the process of comparing the type of transmission lines, it should be noted that the advantages of the cable transmission line. According to the results of the calculation of short-circuit currents, it can be concluded that in networks with a larger line cross-section and a higher voltage, the short-circuit currents are larger. Thus, during the transition of the electric networks to the higher voltage class of 20 kV, the currents of the KZ increased by 43% compared to the 6 kV electric network. This analysis shows that the importance of reliable power supply in the power supply system for high voltage classes must be high and have equipment to prevent emergencies. In the future, it is planned to develop a systematic calculation of short-circuit currents for a number of transmission lines and to conduct mathematical modeling in the system of applications for the study of transient processes at short circuits.


Sign in / Sign up

Export Citation Format

Share Document