Detection of SARS-CoV-2 RNA in nasopharyngeal swabs from COVID-19 patients and asymptomatic cases of infection by real-time and digital PCR

2020 ◽  
Vol 65 (12) ◽  
pp. 785-792
Author(s):  
V. A. Ternovoi ◽  
R. Yu. Lutkovsky ◽  
E. P. Ponomareva ◽  
A. V. Gladysheva ◽  
E. V. Chub ◽  
...  

In this work we tested two reagent kits developed by us for detecting SARS-CoV-2 RNA using a fragment of the ORF1ab gene in digital PCR and real-time PCR formats. Data were obtained on the detection of SARS-CoV-2 virus RNA in nasopharyngeal swabs of patients with COVID-19 and asymptomatic carriers. The developed reagent kits provided 100% sensitivity and a detection limit of 103 GE / ml for qPCR, and at least 200 copies / ml of viral RNA when performing digital PCR. These methods were tested using a panel of 1,328 samples collected from patients with suspected COVID-19 at the beginning of 2020 in the Russian Federation. It has been shown that dPCR is more sensitive and can be used to analyze samples with low viral load, including those from patients without clinical symptoms. dPCR significantly improves the accuracy of laboratory research and significantly reduces the number of false negative results in the diagnosis of SARS-CoV-2. Determination of the concentration of SARS-CoV-2 RNA in patients with different clinical course of the disease showed that the concentration of viral RNA can sharply decrease in the first days of the disease. A low concentration of viral RNA in samples from patients is also characteristic of asymptomatic disease. Digital PCR provides a higher detection rate for asymptomatic cases, which is approximately 75% of those infected, as opposed to 45% for real-time PCR. The results obtained on the use of the digital PCR method for detecting SARS-CoV-2 RNA showed that this method is especially suitable for detecting RNA in case of its low concentration in contacts, as well as for monitoring changes in viral load in convalescent patients.

2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


2021 ◽  
Vol 9 (4) ◽  
pp. 800
Author(s):  
Francesca Servadei ◽  
Silvestro Mauriello ◽  
Manuel Scimeca ◽  
Bartolo Caggiano ◽  
Marco Ciotti ◽  
...  

The aim of this study was to investigate the persistence of SARS-CoV-2 in post-mortem swabs of subjects who died from SARS-CoV-2 infection. The presence of the virus was evaluated post-mortem from airways of 27 SARS-CoV-2 positive patients at three different time points (T1 2 h; T2 12 h; T3 24 h) by real-time PCR. Detection of antibodies to SARS-CoV-2 was performed by Maglumi 2019-nCoV IgM/IgG chemiluminescence assay. SARS-CoV-2 viral RNA was still detectable in 70.3% of cases within 2 h after death and in 66,6% of cases up to 24 h after death. Our data showed an increase of the viral load in 78,6% of positive individuals 24 h post-mortem (T3) in comparison to that evaluated 2 h after death (T1). Noteworthy, we detected a positive T3 post-mortem swab (24 h after death) from 4 subjects who were negative at T1 (2 h after death). The results of our study may have an important value in the management of deceased subjects not only with a suspected or confirmed diagnosis of SARS-CoV-2, but also for unspecified causes and in the absence of clinical documentation or medical assistance.


2010 ◽  
Vol 59 (2) ◽  
pp. 129-132 ◽  
Author(s):  
PIOTR GRABARCZYK ◽  
ALEKSANDRA KALIŃSKA ◽  
EWA SULKOWSKA ◽  
EWA BROJER

Extremely high viremia is observed during some viruses infection, especialy in immunocompromised patients. False negative results of Parvovirus B 19 DNA tests performed with real-time PCR in high viremic samples are reported. The way of fluorescence diagrams analysis and algorithm of positive result confirmation to exclude such phenomenon are proposed.


2020 ◽  
Vol 83 (11) ◽  
pp. 1863-1870
Author(s):  
ANGELA ASSURIAN ◽  
HELEN MURPHY ◽  
ALICIA SHIPLEY ◽  
HEDIYE NESE CINAR ◽  
ALEXANDRE DA SILVA ◽  
...  

ABSTRACT Inhibited reactions have occasionally been observed when cilantro samples were processed for the detection of Cyclospora cayetanensis using quantitative real-time PCR (qPCR). Partial or total inhibition of PCR reactions, including qPCR, can occur, leading to decreased sensitivity or false-negative results. If inhibition occurs, this implies the need for additional purification or cleanup treatments of the extracted DNA to remove inhibitors prior to molecular detection. Our objective was to evaluate the performance of five commercial DNA cleanup kits (QIAquick purification kit from Qiagen [kit 1], OneStep PCR inhibitor removal by Zymo Research [kit 2], NucleoSpin genomic DNA cleanup XS from Macherey-Nagel [kit 3], DNA IQ system by Promega [kit 4], and DNeasy PowerPlant pro kit from Qiagen [5]) to minimize qPCR inhibition using the U.S. Food and Drug Administration–validated Bacteriological Analytical Manual (BAM) Chapter 19b method for detection of C. cayetanensis in cilantro samples containing soil. Each of the five commercial DNA cleanup kits evaluated was able to reduce the qPCR internal amplification control cycle threshold values to those considered to be normal for noninhibited samples, allowing unambiguous interpretation of results in cilantro samples seeded at both a high oocyst level (200 oocysts) and a low oocyst level (10 oocysts). Of the five kits compared, kits 1, 2, and 3 did not show significant differences in the detection of C. cayetanensis, while significantly higher cycle threshold values, indicating lower recovery of the target DNA, were observed from kits 4 and/or 5 in samples seeded with 200 and 10 oocysts (P < 0.05). This comparative study provides recommendations on the use of commercial cleanup kits which could be implemented when inhibition is observed in the detection of C. cayetanensis in cilantro samples using the BAM Chapter 19b method. HIGHLIGHTS


Author(s):  
Michela Deiana ◽  
Chiara Piubelli ◽  
Antonio Mori ◽  
Gian Paolo Chiecchi ◽  
Giulia La Marca ◽  
...  

Background: The reference test for SARS-CoV-2 detection is the reverse transcriptase real time PCR (real time RT-PCR). However, evidences reported that real time RT-PCR has a lower sensitivity compared with the droplet digital PCR (ddPCR) leading to possible false negative in low viral load cases. Methods: We used ddPCR for viral genes N1 and N2 on 20 negative (no detection) samples from symptomatic hospitalized COVID-patients presenting fluctuating real time RT-PCR results and 10 suspected samples (Ct value>35) from asymptomatic not hospitalized subjects. Results: ddPCR performed on RNA revealed 65% of positivity for at least one viral target in the hospitalized patients group of samples (35% for N1 and N2, 10% only for N1 and 20% only for N2) and 50% in the suspected cases (30% for N1 and N2, while 20% only for N2). On hospitalized patients’ samples, we applied also a direct ddPCR approach on the swab material, achieving an overall positivity of 83%. Conclusion: ddPCR, in particular the direct quantitation on swabs, shows a sensitivity advantage for the SARS-CoV-2 identification and may be useful to reduce the false negative diagnosis, especially for low viral load suspected samples.


2006 ◽  
Vol 96 (11) ◽  
pp. 1255-1262 ◽  
Author(s):  
C. Zijlstra ◽  
R. A. Van Hoof

This study describes a multiplex real-time polymerase chain reaction (PCR) approach for the simultaneous detection of Meloidogyne chitwoodi and M. fallax in a single assay. The approach uses three fluorogenic minor groove binding (MGB) TaqMan probes: one FAM-labeled to detect M. chitwoodi, one VIC-labeled to detect M. fallax, and one NED-labeled to detect the internal amplification control (IAC) to monitor false negative results. One common primer set is used for the amplification of part of the internal transcribed spacer (ITS) region of M. chitwoodi and M. fallax and one primer set for the amplification of the IAC. The test enabled detection of M. chitwoodi and/or M. fallax in DNA samples extracted from batches of juveniles, from single juveniles, and from infected plant material. Compared with current assays to detect M. chitwoodi and M. fallax, the multiplex real-time PCR offers the following advantages: it is faster because the test can simultaneously detect both quarantine species without the need for post-PCR processing; and it is at least 10 times more sensitive than a comparable regular PCR also targeting the ITS sequence. Inclusion of the IAC facilitates the interpretation of the FAM and VIC cycle threshold (Ct) values and can prevent the scoring of false negative results when FAM, VIC, and NED Ct values are high. The test allows precise quantification when only one of the two species is present in the sample. However, experiments with mixtures of genomic DNA of M. chitwoodi and M. fallax revealed that the ability of the multiplex real-time PCR assay to detect small quantities of DNA of one species is reduced when large quantities of DNA of the other species are present.


Author(s):  
Lucila Okuyama FUKASAWA ◽  
Maria Gisele GONÇALVES ◽  
Fabio Takenori HIGA ◽  
Maristela Marques SALGADO ◽  
Ana Paula Silva de LEMOS ◽  
...  

2018 ◽  
Vol 30 (5) ◽  
pp. 789-792 ◽  
Author(s):  
Joseph J. Modarelli ◽  
Pamela J. Ferro ◽  
Maria D. Esteve-Gasent

Real-time PCR (rtPCR) tests have become a method of choice in many diagnostic settings, both animal and human. A concern remains, however, regarding rtPCR assay inhibition during nucleic acid extraction and/or rtPCR reaction process that may result in false-negative results. The use of an internal positive control, either endogenous or exogenous, to mitigate this issue has become more commonplace. We identified and standardized an endogenous internal positive control that can be utilized in rtPCR assays targeting canine-specific pathogens in either a singleplex or multiplex format. The target chosen for the endogenous internal positive control (EIPC-K9) was a highly conserved region in canine mitochondrial DNA. Samples from 240 dogs and 11 other species were screened with EIPC-K9; all canine samples were detected, and no cross-amplification with other species tested was observed. Additionally, no inhibition was noted when comparing singleplex to multiplex rtPCR formats.


2004 ◽  
Vol 50 (1) ◽  
pp. 263-270 ◽  
Author(s):  
M. Lebuhn ◽  
M. Effenberger ◽  
G. Garcés ◽  
A. Gronauer ◽  
P.A. Wilderer

We evaluated quantitative real-time PCR (qPCR) and RTqPCR (for RNA species) for their ability to quantify microorganisms and viruses in problematic environmental samples such as cattle manure, digester material, wastewater and soil. Important developments included a standard spiking approach which compensated for methodological bias and allowed sample-to-sample comparison and reliable quantification. Programme CeTe was developed to calculate endogenous concentrations of target organisms (nucleic acid copies) for each sample separately from the generated standard curves. The approach also permitted assessment of the detection limit of the complete method, including extraction. It varied from sample to sample, due to different extraction efficiencies and variable co-extraction of PCR inhibitors. False negative results were thereby avoided. By using this approach we were able to optimise a DNA extraction protocol from the different tested sample types. Protocols for the extraction of RNA species from environmental samples were also optimised. DNA was (almost) not degraded after lethal shock (autoclaving) in the sterile environment. In contrast, the parallel selective cultivation and qPCR results for various microbial parameters from an anaerobic digester chain suggested that DNA from decaying organisms was readily recycled in metabolically active environments. It may, therefore, be used to determine viable organisms in samples exhibiting substantial metabolic turnover. It is proposed that our standard spiking approach, including data evaluation by the program CeTe, should be considered in future standardisation and norms for the quantification of nucleic acid containing organisms in environmental and product samples.


Sign in / Sign up

Export Citation Format

Share Document